YFYunfei Fang

Yunfei Fang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yunfei Fang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Xikai Liu

    Ningbo Institute of Technology, Beihang University, Ningbo 315800, China; Zhejiang Engineering Research Center of Precision Electromagnetic Control Technology and Equipment, Ningbo 315800, China

    4 shared publications
  • Bangcheng Han

    School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China

    3 shared publications
  • Tong Wen

    School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China

    3 shared publications
  • Pengfei Song

    Zhejiang Engineering Research Center of Precision Electromagnetic Control Technology and Equipment, Ningbo Institute of Technology, Beihang University, Ningbo 315800, China

    2 shared publications
  • Yimin Chen

    School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China

    2 shared publications
  • Jiqiang Tang

    School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China

    1 shared publication

Latest Publications

  • Highly Homogeneous and Low-Noise Magnetic Field Compensation Based on the High-Uniform Magnetic Field Coils With Small Coil Constant

    by Yimin Chen, Tong Wen, Yunfei Fang, Bangcheng Han, Xikai Liu

    A highly homogeneous and low-noise magnetic field is crucial for the development of devices based on optically pumped magnetometers (OPMs). However, the creation of a highly homogeneous and low-noise magnetic field in a large region remains a technical challenge. This work describes the development of a highly precise active magnetic field compensation system based on high-uniform magnetic field coils (H-UMFCs) with a small and adjustable coil constant. The H-UMFCs are designed with reference to a self-shielding coil based on the magnetic moment compensation strategy. The proportional magnification coefficient and the current scaling coefficient of the two sets of coils are optimized to obtain high uniformity in a large region. Compared with the traditional one set of planar coils, the uniformity of the Bx coils is improved by more than six times in the same region. The active magnetic field compensation system was developed based on H-UMFCs with the coil constant reduced by controlling the current ratio of the two sets of wires in one wire slot. The performance of the compensation system was verified by experimental testing. A highly homogeneous and low-noise magnetic field environment was created with a noise of less than 10 fT/√Hz@1 Hz. The design strategy is important in the application of OPMs.


  • Suppression of the Ferromagnetic Boundary Coupling and Precision Control of Magnetic Field with the Self-Shielding Method

    by Yimin Chen, Xikai Liu, Shuai Dou, Yunfei Fang, Pengfei Song, Tong Wen, Bangcheng Han

    Ferromagnetic boundary coupling is one key factor that limits the control accuracy of the residual magnetic field in the magnetic shielding room. Usually the image method is utilized to suppress the coupling, but the tolerance for door slit and holes of the image method is poor. Here, we propose the self-shielding method for suppressing the ferromagnetic boundary coupling with higher coupling suppression ability and better tolerance for door slit and holes. Two sets of biplane coils for one axis are designed for achieving uniform magnetic field in the target area and nearzero magnetic field in the shielding area near the passive metal shielding layer simultaneously. We have determined the analysis method and design process of the self-shielding method, and verified its feasibility by experimental test. The proposed method can provide new ideas for improving the control accuracy of the residual magnetic field in the magnetic shielding room, ensuring the smooth progress of magnetoencephalography measurement.


  • Research on Magnetic Field Compensation Method Based on Fuzzy PI Control for Low Remanence in Magnetic Shielding Room

    by Jiqiang Tang, Yunfei Fang, Xikai Liu, Shengyi Shangguan

    An active magnetic compensation method based on passive shielding is used for low remanence and interfering field suppression in a lower cost magnetic shielding room (MSR). In this paper, a compensation coil control strategy with conventional PI and fuzzy PI segmentation control is proposed, and an active magnetic compensation system with a linearized model is built using an external high uniformity Helmholtz coil. The result shows that the compensation system has a greatly improvement in the suppression of the interfering magnetic field in the environment while ensuring good step response performance of the controller.


  • Design of Self-Shielding Uniform Coils Based on Bat Algorithm

    by Yimin Chen, Pengfei Song, Xikai Liu, Yueteng Jiang, Tong Wen, Bangcheng Han

    The ferromagnetic boundary coupling effect is an important factor affecting the coil uniformity, and the non-moment coils (NMCs) design method is often used to solve this problem. This paper proposes a non-moment planar coils (NMPCs) design method based on bat algorithm (BA) and self-shielding method, which can inhibit the coupling effect between the coils and the high magnetic permeability shielding layer, and improve the uniformity of the target region. We design Bx and Bz NMPCs, and use finite element software to simulate and calculate, verifying the performance of the method. Compared with ordinary planar coils (OPCs) in the shielding layer, the target region uniformity of this method has been significantly improved, Bx and Bz have increased by a factor of 17.28 and 10.57 respectively. This method can provide a new coil design idea for precise ultra-weak magnetic testing.