YXYifei Xu

Yifei Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yifei Xu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electroacoustic tomography with dual-frequency array for real-time monitoring of electroporation

    by Luke Xu, Yifei Xu, Liangzhong Xiang

    Electroacoustic Tomography (EAT) is an imaging technique that detects ultrasound waves induced by electrical pulses, offering a solution for real-time electroporation monitoring. This study presents EAT system using a dual-frequency ultrasound array. The broadband nature of electroacoustic signals requires ultrasound detector to cover both the high-frequency range (around [ ] [ ]MHz) signals generated by small targets and the low-frequency range (around [ ] [ ]MHz) signals generated by large targets. In our EAT system, we use the 6 MHz array to detect high-frequency signals from the electrodes, and the 1 MHz array for the electrical field. To test this, we conducted simulations using COMSOL Multiphysics[ ] and MATLAB’s k-Wave toolbox, followed by experiments using a custom-built setup with a dual-frequency transducer and real-time data acquisition. The results demonstrated that the dual-frequency EAT system could accurately and simultaneously monitor the electroporation process, effectively showing both the treatment area and electrode placement with the application of 1[ ]kV electric pulses with 100[ ]ns duration. The axial resolution of the 6[ ]MHz array for EAT was 0.45[ ]mm, significantly better than the 2[ ]mm resolution achieved with the 1[ ]MHz array. These findings validate the potential of dual-frequency EAT as a superior method for real-time electroporation monitoring.


  • Non-contact electroacoustic tomography with optical interferometer for electroporation therapy monitoring

    by Yifei Xu, Yuchen Song, Leshan Sun, Zhongping Chen, Liangzhong Xiang

    Electroacoustic imaging is an imaging modality used to detect electric field energy distribution during electroporation, offering valuable guidance for clinical procedures, particularly in deep tissues. Traditionally, single-element piezoelectric transducers or arrays have been employed for this purpose. However, these piezoelectric sensors are sensitive to electromagnetic interference and require physical contact with the sample through a coupling medium, raising concerns for both clinical and preclinical applications. To overcome these limitations, a multi-channel random quadrature ultrasonics system has been developed, enabling non-contact detection of electroacoustic signals. In this study, we demonstrated that this non-contact technique effectively detects electroacoustic signals, identifies electroporation regions, and reconstructs electric energy distribution, offering a promising approach for monitoring electroporation therapy.


  • Open Access

    X-ray–induced acoustic computed tomography: 3D X-ray absorption imaging from a single view

    by Siqi Wang, Prabodh Kumar Pandey, Gerald Lee, Rick J. P. van Bergen, Leshan Sun, Yifei Xu, Liangzhong) Xiang

    Computed tomography (CT) scanners are essential for modern imaging but require around 600 projections from various angles. We present x-ray–induced acoustic computed tomography (XACT), a method that uses radiation-induced acoustic waves for three-dimensional (3D) x-ray imaging. These spherical acoustic waves travel through tissue at 1.5 × 10 3 meters per second, much slower than x-rays, allowing ultrasound detectors to capture them and generate 3D images without mechanical scanning. We validate this theory by performing 3D numerical reconstructions of a human breast from a single x-ray projection and experimentally determining 3D structures of objects at different depths. Achieving resolutions of 0.4 millimeters in the XZ plane and 3.5 millimeters in the XY plane at a depth of 16 millimeters, XACT demonstrates the ability to produce 3D images from one x-ray projection, reducing radiation exposure and enabling gantry-free imaging. XACT shows great promise for biomedical and nondestructive testing applications, potentially replacing conventional CT.


  • Combined XA/CT Imaging for Bone Density and Elasticity Evaluation: A Simulation Study

    by Leshan Sun, Yifei Xu, Prabodh Kumar Pandey, Liangzhong Xiang

    Osteoporosis is a significant public health concern that affects old adults and individuals with certain medical conditions. In this work, we demonstrate the proof of the principle of combining the emerging new radiological imaging technique, X-ray-induced acoustic (XA) imaging, and X-ray computed tomography (CT) for bone density and elasticity evaluation. This combined method is intended for use in single scanner that can perform both XA imaging and CT imaging simultaneously for the purpose of providing accurately registered anatomical localization of structures seen in the CT image to extract the elasticity information in XA imaging. We demonstrate that our nonlinear optimization algorithm can acquire the speed of sound information for bone. By combining the speed of sound and density information from CT, we can calculate the elasticity with an error of less than 1%. We conclude that using CT information as prior information is a feasible way to obtain elasticity information in XA imaging. These findings enable more accurate osteoporosis diagnosis through both bone density and bone strength evaluation using one integrated system in the future.


  • Open Access

    Electroacoustic tomography for real-time visualization of electrical field dynamics in deep tissue during electroporation

    by Yifei Xu, Leshan Sun, Siqi Wang, Yuchen Yan, Prabodh Pandey, Vitalij Novickij, Liangzhong Xiang

    Despite the widespread applications of electroporation in biotechnology and medicine, monitoring the distribution of deep tissue electrical fields in real-time during treatment continues to pose a challenge. Current medical imaging modalities are unable to monitor electroporation during pulse delivery. Here we propose a method to use electroacoustic tomography (EAT) to prompt the emission of broadband ultrasound waves via electrical energy deposition. EAT boasts submillimeter resolution at depths reaching 7.5 centimeters and can deliver imaging speeds up to 100 frames per second when paired with an ultrasound array system. We’ve successfully detected EAT signals at electric field strengths ranging from 60 volts per centimeter to several tens of kilovolts per centimeter. This establishes EAT as a potential label-free, high-resolution approach for real-time evaluation of deep tissue electroporation during therapeutic procedures.