JHJian Hu

Jian Hu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jian Hu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Haidong Chen

    Guangdong Provincial Key Laboratory of Millimeter-Wave and Terahertz, Guangdong-Hong Kong-Macao Joint Laboratory for Millimeter-Wave and Terahertz, School of Electronic and Information Engineering, South China University of Technology, Guangzhou, China

    1 shared publication
  • Haitian Zhou

    School of Electronic and Information Engineering, South China University of Technology, Guangzhou, China

    1 shared publication
  • Jieyao Yang

    School of Electronic and Information Engineering, South China University of Technology, Guangzhou, China

    1 shared publication
  • Jun Zhang

    Infosky Technology Company Ltd., Shunyi, Beijing, China

    1 shared publication
  • Linbo Chen

    School of Electronics and Information Engineering, South China University of Technology, Guangzhou, China

    1 shared publication
  • Mengzhu Yan

    Guangdong Provincial Key Laboratory of Millimeter-Wave and Terahertz, Guangdong-Hong Kong-Macao Joint Laboratory for Millimeter-Wave and Terahertz, School of Electronics and Information Engineering, South China University of Technology, Guangzhou, China

    1 shared publication

Latest Publications

  • Advanced Multiprobe Dual-Polarized Arch System for Microwave Reflectance Measurement

    by Haidong Chen, Zhaoling He, Jieyao Yang, Weijun Zhong, Haitian Zhou, Mengzhu Yan, Yi Wang, Jun Zhang, Weijie Lin, Linbo Chen, et al.

    This paper proposes a new dual-polarization multi-probe arch measurement system with a 2-18 GHz measurement frequency range. The basic principle of the arch measurement system is reviewed, and the hardware is introduced in detail. Based on the simulated results, the time gating method is presented, proving a useful way to reduce spurious coupling and clutter interference. The proposed arch measurement system is implemented and some materials such as commercial PTFE, FR-4, and customized paper-based honeycomb N15 are measured for verification. The results based on our proposed method have approximately +/-2 dB amplitude differences and 1 GHz frequency shift compared to those results based on the RCS method, and approximately 5 dB amplitude differences and 2 GHz shift compared to those results based on another customized arch system. The calculated uncertainty of the whole system is less than 4 dB and the measurement time of a single sample is within 2 minutes. The proposed measurement system has remarkable advantages such as high measurement accuracy, fast measurement speed, and wide application range.