Li Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Li Liu has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Tao Dang5 shared publications
Jun Cao
4 shared publicationsShuting Li
3 shared publications- Xin Zhuo3 shared publications
Yile Mao
3 shared publications- Dan Liang
Ningbo Key Laboratory of Micro‐Nano Motion and Intelligent Control Ningbo University Ningbo People's Republic of China
2 shared publications
Latest Publications
- 24 October 2026
- Published by Elsevier in Tribology International
- Vol. 227
Design and microscopic–macroscopic study of calcium silicate/zinc oxide–modified GO/h-BN coatings for atlantoaxial joint replacement
- 24 October 2026
- Published by Elsevier in Tribology International
- Vol. 227
Design and microscopic–macroscopic study of calcium silicate/zinc oxide–modified GO/h-BN coatings for atlantoaxial joint replacement
- Open Access
- 17 June 2026
- Published by Elsevier in SSRN Electronic Journal
Tribological and anti-cavitation erosion performance of PI/PTFE soft coating on 45# steel and CuPb22.5Sn2.5 alloy
Severe degradation of tribological performance and surface cavitation damage were frequently observed in water-lubricated bearings subjected to low-speed, heavy-load, and frequent start-stop operating conditions. To extend the service life and investigate the influence of substrate hardness and elastic modulus on coating performance, PI/PTFE coatings were prepared on CuPb22.5Sn2.5 copper alloy and 45# steel surfaces via liquid spraying. Furthermore, Molecular Dynamics (MD) simulations were employed to analyze the interfacial interactions, revealing that the shear deformation of polymer chains dominated the interfacial friction. Experimental results indicated that the copper-based coating exhibited superior tribological performance compared to the steel substrate due to higher H/E and H³/E² ratios under dry friction, reducing the coefficient of friction (CoF) and wear rate by 59.2% and 16.6%, respectively. Additionally, three-body abrasion and abrasive wear were effectively mitigated by the coating compared with the uncoated copper alloy, yielding significant decreases of 65.7% and 19.7% in CoF and wear rate. However, under seawater lubrication, tribological performance was primarily governed by the coupling effect between the coating’s mechanical properties and the lubrication environment. Consequently, the steel-based coating exhibited tribological performance comparable or superior to the copper-based system. Furthermore, in seawater cavitation experiments, the steel-based coating demonstrated the highest erosion resistance, reducing mass loss by 28.7% relative to the uncoated copper alloy, as its H³/E² value effectively withstood mechanical impacts. In summary, the tribological behavior and cavitation resistance were primarily governed by plastic deformation resistance (characterized by H/E and H³/E² ratios) and the material-medium coupling effect under specific lubrication conditions.
- 17 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTribological and anti-cavitation erosion performance of PI/PTFE soft coating on 45# steel and CuPb22.5Sn2.5 alloy
Severe degradation of tribological performance and surface cavitation damage were frequently observed in water-lubricated bearings subjected to low-speed, heavy-load, and frequent start-stop operating conditions. To extend the service life and investigate the influence of substrate hardness and elastic modulus on coating performance, PI/PTFE coatings were prepared on CuPb22.5Sn2.5 copper alloy and 45# steel surfaces via liquid spraying. Furthermore, Molecular Dynamics (MD) simulations were employed to analyze the interfacial interactions, revealing that the shear deformation of polymer chains dominated the interfacial friction. Experimental results indicated that the copper-based coating exhibited superior tribological performance compared to the steel substrate due to higher H/E and H³/E² ratios under dry friction, reducing the coefficient of friction (CoF) and wear rate by 59.2% and 16.6%, respectively. Additionally, three-body abrasion and abrasive wear were effectively mitigated by the coating compared with the uncoated copper alloy, yielding significant decreases of 65.7% and 19.7% in CoF and wear rate. However, under seawater lubrication, tribological performance was primarily governed by the coupling effect between the coating’s mechanical properties and the lubrication environment. Consequently, the steel-based coating exhibited tribological performance comparable or superior to the copper-based system. Furthermore, in seawater cavitation experiments, the steel-based coating demonstrated the highest erosion resistance, reducing mass loss by 28.7% relative to the uncoated copper alloy, as its H³/E² value effectively withstood mechanical impacts. In summary, the tribological behavior and cavitation resistance were primarily governed by plastic deformation resistance (characterized by H/E and H³/E² ratios) and the material-medium coupling effect under specific lubrication conditions.
- Open Access
- 16 April 2026
- Published by Elsevier in SSRN Electronic Journal
Tribological performance and cavitation erosion resistance of the PI/PTFE soft coating on CuPb22.5Sn2.5 and 45# steel
Severe degradation of tribological performance and surface cavitation damage were frequently observed in water-lubricated bearings subjected to low-speed, heavy-load, and frequent start-stop operating conditions. To extend the service life and investigate the influence of substrate hardness and elastic modulus on coating performance, PI/PTFE coatings were prepared on CuPb22.5Sn2.5 copper alloy and 45# steel surfaces via liquid spraying. Furthermore, Molecular Dynamics (MD) simulations were employed to analyze the interfacial interactions, revealing that the shear deformation of polymer chains dominated the interfacial friction. Experimental results indicated that the copper-based coating exhibited superior tribological performance compared to the steel substrate due to higher H/E and H³/E² ratios under dry friction, reducing the coefficient of friction (CoF) and wear rate by 59.2% and 16.6%, respectively. Additionally, three-body abrasion and abrasive wear were effectively mitigated by the coating compared with the uncoated copper alloy, yielding significant decreases of 65.7% and 19.7% in CoF and wear rate. However, under seawater lubrication, tribological performance was primarily governed by the coupling effect between the coating’s mechanical properties and the lubrication environment. Consequently, the steel-based coating exhibited tribological performance comparable or superior to the copper-based system. Furthermore, in seawater cavitation experiments, the steel-based coating demonstrated the highest erosion resistance, reducing mass loss by 28.7% relative to the uncoated copper alloy, as its H³/E² value effectively withstood mechanical impacts. In summary, the tribological behavior and cavitation resistance were primarily governed by plastic deformation resistance (characterized by H/E and H³/E² ratios) and the material-medium coupling effect under specific lubrication conditions.
- 16 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTribological performance and cavitation erosion resistance of the PI/PTFE soft coating on CuPb22.5Sn2.5 and 45# steel
Severe degradation of tribological performance and surface cavitation damage were frequently observed in water-lubricated bearings subjected to low-speed, heavy-load, and frequent start-stop operating conditions. To extend the service life and investigate the influence of substrate hardness and elastic modulus on coating performance, PI/PTFE coatings were prepared on CuPb22.5Sn2.5 copper alloy and 45# steel surfaces via liquid spraying. Furthermore, Molecular Dynamics (MD) simulations were employed to analyze the interfacial interactions, revealing that the shear deformation of polymer chains dominated the interfacial friction. Experimental results indicated that the copper-based coating exhibited superior tribological performance compared to the steel substrate due to higher H/E and H³/E² ratios under dry friction, reducing the coefficient of friction (CoF) and wear rate by 59.2% and 16.6%, respectively. Additionally, three-body abrasion and abrasive wear were effectively mitigated by the coating compared with the uncoated copper alloy, yielding significant decreases of 65.7% and 19.7% in CoF and wear rate. However, under seawater lubrication, tribological performance was primarily governed by the coupling effect between the coating’s mechanical properties and the lubrication environment. Consequently, the steel-based coating exhibited tribological performance comparable or superior to the copper-based system. Furthermore, in seawater cavitation experiments, the steel-based coating demonstrated the highest erosion resistance, reducing mass loss by 28.7% relative to the uncoated copper alloy, as its H³/E² value effectively withstood mechanical impacts. In summary, the tribological behavior and cavitation resistance were primarily governed by plastic deformation resistance (characterized by H/E and H³/E² ratios) and the material-medium coupling effect under specific lubrication conditions.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (4) , 4010-4017
Design and Analysis of Hybrid Rigid-Soft Self-Aligning Index Finger Exoskeleton
Disrupted hand motor functions may be restored through exoskeleton-assisted rehabilitation training. However, the variability of soft tissue in human joints or across individuals and development of an exoskeleton that combines human-machine motion compatibility and dynamic compliance pose persistent challenges. We introduce a hybrid single-motor-driven rigid–soft exoskeleton for the index finger to assist in rehabilitation training. A rigid parallel mechanism directly drives the soft component of the metacarpophalangeal (MCP) joint. In addition, we adopt an interlocking mechanism to induce deformation in leaf springs, enabling the coordinated flexion and extension of multiple joints. A motion analysis based on the modified Denavit–Hartenberg convention confirms that the proposed parallel mechanism can compensate for the misalignment displacement of the MCP joint. Based on the displacement and force applied to the soft component by the designed rigid parallel mechanism, kinematic and static analyses along with dimensional optimization are performed on a dual-segment parallel leaf spring. A prototype exoskeleton undergoing tests demonstrated Pearson correlation coefficients of 0.998, 0.991, 0.986, for the MCP, proximal and distal interphalangeal (PIP/DIP) joints, respectively. The corresponding joint flexion angles were 68.19°, 81.91°, and 41.64°. The exoskeleton self-aligns with the index finger joints, properly assisting the natural bending motion of the finger to meet rehabilitation training needs of patients. The proposed exoskeleton can assist with a fingertip force of 6.2 N, thereby satisfying grip requirements, while the reduced force on the dorsal surface of the index finger enhances comfort during use. The proposed solution is promising for developing hand exoskeletons.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (4) , 4010-4017
Design and Analysis of Hybrid Rigid-Soft Self-Aligning Index Finger Exoskeleton
Disrupted hand motor functions may be restored through exoskeleton-assisted rehabilitation training. However, the variability of soft tissue in human joints or across individuals and development of an exoskeleton that combines human-machine motion compatibility and dynamic compliance pose persistent challenges. We introduce a hybrid single-motor-driven rigid–soft exoskeleton for the index finger to assist in rehabilitation training. A rigid parallel mechanism directly drives the soft component of the metacarpophalangeal (MCP) joint. In addition, we adopt an interlocking mechanism to induce deformation in leaf springs, enabling the coordinated flexion and extension of multiple joints. A motion analysis based on the modified Denavit–Hartenberg convention confirms that the proposed parallel mechanism can compensate for the misalignment displacement of the MCP joint. Based on the displacement and force applied to the soft component by the designed rigid parallel mechanism, kinematic and static analyses along with dimensional optimization are performed on a dual-segment parallel leaf spring. A prototype exoskeleton undergoing tests demonstrated Pearson correlation coefficients of 0.998, 0.991, 0.986, for the MCP, proximal and distal interphalangeal (PIP/DIP) joints, respectively. The corresponding joint flexion angles were 68.19°, 81.91°, and 41.64°. The exoskeleton self-aligns with the index finger joints, properly assisting the natural bending motion of the finger to meet rehabilitation training needs of patients. The proposed exoskeleton can assist with a fingertip force of 6.2 N, thereby satisfying grip requirements, while the reduced force on the dorsal surface of the index finger enhances comfort during use. The proposed solution is promising for developing hand exoskeletons.
- Open Access
- 3 February 2026
- Published by Elsevier in SSRN Electronic Journal
Tribological performance and cavitation erosion resistance of the PI/PTFE soft coating on CuPb22.5Sn2.5 and 45# steel
Severe degradation of tribological performance and surface cavitation damage were frequently observed in water-lubricated bearings subjected to low-speed, heavy-load, and frequent start-stop operating conditions. To extend the service life and investigate the influence of substrate hardness and elastic modulus on coating performance, PI/PTFE soft coatings were prepared on CuPb22.5Sn2.5 copper alloy and 45# steel surfaces via liquid spraying. Furthermore, Molecular Dynamics (MD) simulations were employed to analyze the interfacial interactions between the substrate and the coating under dry friction at the atomic scale, elucidating microscopic wear mechanisms. Results indicated that the coating on the copper alloy exhibited superior tribological performance compared to the steel substrate under dry friction, attributed to higher H/E and H³/E² ratios. Specifically, the coefficient of friction (CoF) and wear rate of the coating on the copper alloy were reduced by 59.2% and 16.6%, respectively. Additionally, three-body abrasion and abrasive wear were effectively mitigated by the coating compared with the uncoated copper alloy, resulting in significant decreases of 65.7% and 19.7% in CoF and wear rate, respectively. However, under seawater lubrication, tribological performance was primarily governed by the coupling effect between the coating's mechanical properties and the lubrication environment. Consequently, the coating on the steel substrate exhibited tribological performance comparable or superior to the copper-based system. In summary, the tribological behavior of the coatings was primarily governed by the resistance to plastic deformation (characterized by H/E and H³/E² ratios) and the coupling effect between the material and the medium under specific lubrication conditions.
- 3 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTribological performance and cavitation erosion resistance of the PI/PTFE soft coating on CuPb22.5Sn2.5 and 45# steel
Severe degradation of tribological performance and surface cavitation damage were frequently observed in water-lubricated bearings subjected to low-speed, heavy-load, and frequent start-stop operating conditions. To extend the service life and investigate the influence of substrate hardness and elastic modulus on coating performance, PI/PTFE soft coatings were prepared on CuPb22.5Sn2.5 copper alloy and 45# steel surfaces via liquid spraying. Furthermore, Molecular Dynamics (MD) simulations were employed to analyze the interfacial interactions between the substrate and the coating under dry friction at the atomic scale, elucidating microscopic wear mechanisms. Results indicated that the coating on the copper alloy exhibited superior tribological performance compared to the steel substrate under dry friction, attributed to higher H/E and H³/E² ratios. Specifically, the coefficient of friction (CoF) and wear rate of the coating on the copper alloy were reduced by 59.2% and 16.6%, respectively. Additionally, three-body abrasion and abrasive wear were effectively mitigated by the coating compared with the uncoated copper alloy, resulting in significant decreases of 65.7% and 19.7% in CoF and wear rate, respectively. However, under seawater lubrication, tribological performance was primarily governed by the coupling effect between the coating's mechanical properties and the lubrication environment. Consequently, the coating on the steel substrate exhibited tribological performance comparable or superior to the copper-based system. In summary, the tribological behavior of the coatings was primarily governed by the resistance to plastic deformation (characterized by H/E and H³/E² ratios) and the coupling effect between the material and the medium under specific lubrication conditions.
- 4 September 2025
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 150
Design and analysis of a spherical wheel-legged hybrid robot with leg adjustment modules for enhanced locomotion performance
- 4 September 2025
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 150
Design and analysis of a spherical wheel-legged hybrid robot with leg adjustment modules for enhanced locomotion performance
- 16 November 2024
- Published by Elsevier in Precision Engineering
- Vol. 91, 716-727
Rapid non-contact measurement of distance between two pins of flexspline in harmonic reducers based on standard/actual parts comparison
- 16 November 2024
- Published by Elsevier in Precision Engineering
- Vol. 91, 716-727
Rapid non-contact measurement of distance between two pins of flexspline in harmonic reducers based on standard/actual parts comparison
- Open Access
- 1 December 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2674 (1) , 012004
Precision Measurement of Dimension over Two Pins of Flexspline of Harmonic Reducer
This paper presents a comparative method for accurately measuring dimension over two pins of flexspline of harmonic reducer. Firstly, we design a measuring system and introduce its composition and measuring principle. Secondly, we propose an alignment method to reduce measurement error caused by eccentric installation. Finally, the alignment method proposed was experimentally verified, and the dimension over two pins of flexspline was measured. The verification results showed that the proposed alignment method had a positive effect, and its feasibility was confirmed. Dimension over two pins of standard flexspline was found to be 64.855 mm. By employing the proposed comparison method, the dimension over two pins of the three measured flexsplines was 64.848 mm, 64.862 mm, and 64.857 mm, respectively. The measurement accuracy achieved was less than 10 μm, meeting the required measurement accuracy standards and significantly improving upon traditional measurement methods.
- 1 December 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2674 (1) , 012004
Open AccessPrecision Measurement of Dimension over Two Pins of Flexspline of Harmonic Reducer
This paper presents a comparative method for accurately measuring dimension over two pins of flexspline of harmonic reducer. Firstly, we design a measuring system and introduce its composition and measuring principle. Secondly, we propose an alignment method to reduce measurement error caused by eccentric installation. Finally, the alignment method proposed was experimentally verified, and the dimension over two pins of flexspline was measured. The verification results showed that the proposed alignment method had a positive effect, and its feasibility was confirmed. Dimension over two pins of standard flexspline was found to be 64.855 mm. By employing the proposed comparison method, the dimension over two pins of the three measured flexsplines was 64.848 mm, 64.862 mm, and 64.857 mm, respectively. The measurement accuracy achieved was less than 10 μm, meeting the required measurement accuracy standards and significantly improving upon traditional measurement methods.