ZLZiting Liang

Ziting Liang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ziting Liang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Compact High-Performance MR Safe Pneumatic Stepper Motor

    by Ziting Liang, Ryman Hashem, Chuang Lu, Mohamed E.M.K. Abdelaziz, Steve Bandula, Vincent Groenhuis, Stefano Stramigioli, Danail Stoyanov, Agostino Stilli

    Magnetic resonance imaging (MRI)-guided interventions have advanced rapidly due to their superior soft-tissue contrast and real-time imaging capability. To enable actuation for robots and other medical devices used in tumour biopsy and ablation within magnetically sensitive environments, several MRI-compatible pneumatic motors have been developed using 3D printing. Although 3D printing enables the fabrication of pneumatic structures, maintaining airtightness and smooth piston motion within 3D-printed cylinders remains challenging due to tolerance variations and surface roughness. These issues lead to pressure losses, increased air consumption, and reduced torque output during motor operation. To address these challenges, this paper presents a compact, high-performance, easily manufacturable MR Safe pneumatic stepper motor that circumvents 3D-printing tolerance limitations by employing prefabricated cylinders. The motor combines a replaceable design with great airtightness and high torque performance. The proposed design achieves negligible air leakage of 0.047 mL/min measured via a designed water displacement method and a maximum output torque of 1.04 Nm at 3.7 revolutions per minute (rpm) under 6 bar, without an additional gearbox. The motor has a compact design, 48 × 48 × 36 mm, which enables the motor to be integrated into the medical devices within the narrow MRI scanning bore.

  • Open Access

    TDN-PPO: An Automatic Control Framework of a Surgical Robot for Posterior Segment Ophthalmic Surgery

    by Ning Wang, Xiaodong Zhang, Sophia Bano, Danail Stoyanov, Ziting Liang, Agostino Stilli

    In ophthalmic surgery, particularly the procedures involving the posterior segment, clinicians face significant challenges in maintaining precise control of handheld instruments to peel fragile membranes without damaging the surrounding healthy fundus tissue, even for seasoned clinicians employing specialised ophthalmic surgical robots. The implementation of autonomous control in robot-assisted surgical systems holds promise for overcoming these obstacles and simplifying intricate surgical tasks. This paper introduces an autonomous control framework, integrating a Tip Detection Network (TDN) with a Proximal Policy Optimization (PPO) network, designed to autonomously navigate the Tip of the Surgical Instrument (ToSI) towards the intended lesion site in a real-world scenario. Results indicate that the accuracy of the TDN module in detecting the ToSI position in images of varying sizes can be reliably maintained within a 4.6-pixel range. The autonomous control deviation for the PPO module ranges between [0.6585μm, 7.995μm], with an average discrepancy of 5.118μm. The communication frequency across the modules is maintained at 35.7 Hz. In physical environments, the TDN-PPO framework adeptly navigates the ToSI to autonomously and precisely converge on the preset Target Lesion (TL) macular hole, maintaining a tip-to-target distance error within a margin of 2.094 pixels (38μm). Throughout the autonomous navigation phase, the maximal contact force between the ToSI and the TL is capped at 41.1 mN, aligning with the upper threshold for contact force between the ToSI and tissue prescribed in clinical surgical settings.

  • GelPoLight: A Novel Visual-Tactile Sensor Based on Photometric Stereo With Point Lighting

    by Chuang Lu, Ziting Liang, Danail Stoyanov, Agostino Stilli

    Visual tactile sensors based on photometric stereo (VTS-PS) have attracted much attention due to their sensitivity to subtle contact forces and their capability of providing real-time, high-resolution depth maps of contact geometry at a low cost. Conventional VTS-PS, such as Gelsight, typically assume directional and uniform illumination to simplify the algorithm of photometric stereo. However, this assumption poses stringent requirement on the hardware side and limits the sensors in shape, size and flexibility for various applications. Additionally, the configuration of directional lighting exacerbates the issue of cast shadowing. In this paper, We analyse the benefits of point lighting over conventional directional lighting for VTS-PS, and propose GelPoLight: a novel VTS-PS with point lighting, which can help handle or alleviate the aforementioned problems. GelPoLight does not assume ideal diffuse reflectance for the reflective membrane and considers the varying influencing factors of light intensity, light directions, and reflectance factors in the estimation of surface normal vectors. Accordingly, we developed a new calibration method for this approach. We also corrected image distortions caused by light refraction, which is a prevalent issue in visual tactile sensors (VTS). The final results demonstrate that GelPoLight can effectively generate the contact depth map, with errors of approximately 5% in planar direction and 8% in depth direction.


  • Magnetic Resonance Imaging-Guided Needle Insertion Robots: A Review of Systems for Liver and Kidney Interventions [Survey]

    by Ziting Liang, Lukas Lindenroth, Ryman Hashem, Steve Bandula, Danail Stoyanov, Agostino Stilli

    Magnetic resonance imaging (MRI)-guided intervention for the liver and kidney has achieved considerable progress in tumor diagnosis and treatment over the past two decades. However, due to the space constraints associated with the narrow and deep bore of MRI machines, it is still extremely challenging for clinicians to position and drive the needle-shaped probes used for delivering the treatment where the targeted tumoral mass is located. MRI-compatible robotic systems have been investigated by several research teams worldwide, both in academia and industry. These endeavors aim to address challenges related to the confined workspace within MRI machine bores. The goal is to facilitate the shift from computed tomography (CT)-guided to MRI-guided interventions, leveraging the advantages of MRI, including its exceptional soft tissue contrast, nonionizing radiation, and versatile multiangle imaging capabilities. In this article, we systematically review the state-of-the-art MRI-guided needle insertion robots for the treatment of the liver and kidney in order to identify challenges, trends, and potential research gaps in this field. Furthermore, this review encompasses robotic systems designed for anatomically similar regions or exhibiting comparable structures to those intended for interventions in the liver and kidney. These systems, which have shown potential for application in this field, are discussed to explore possibilities within this domain. The review concludes by proposing future research directions in this area.