MDMatthieu Dalstein

Matthieu Dalstein

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Matthieu Dalstein has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analysis of Corona and Surface Discharge Signals from Different Non-Intrusive Sensors under HVDC

    by Ayyoub Zouaghi, Florent Coutanson, Matthieu Dalstein, Sneha Satish Hegde, Guy Clerc, Christian Vollaire

    The use of high voltage direct current (HVDC) transmission technology has increased significantly in recent years due to its numerous advantages over traditional alternating current (AC) transmission. The aim of the present work is to investigate the efficiency of different non-intrusive sensors for partial discharge measurement in medium or high voltage direct current equipment such as air or gas insulated switchgear. In HVAC systems, partial discharge detection and quantification are well understood. However, under HVDC, it is a necessary to evaluate the efficiency of classic techniques and commercial non-intrusive sensors. This work presents a study of three different sensors for partial discharge measurement under HVDC: high frequency current transformer (HFCT), ultra-high frequency antenna (UHF), and transient earth voltage (TEV). The signals of the different sensors for corona and surface discharge detection are presented and compared in both temporal and frequency domains. The Pulse Sequence Analysis (PSA) technique is used for apparent charge and repetition rate study and the effect of the discharge type on the PSA patterns is investigated. The results show that the PSA patterns are sensitive to the discharge type and conditions. The increase of the applied voltage of corona leads to the increase of the apparent charge differences and the time duration between successive pulses. The spectrums of the discharge pulses of the three sensors are different and the maxima of the TEV and UHF PD signals are dependent on the apparent charge.

  • Methods for Partial Discharge Calibration in Gas-Insulated Substations for HVDC Power Grids and Charge Evaluation Uncertainty

    by Christian Mier Escurra, Abderrahim Khamlichi, Matthieu Dalstein, José Ramón Vidal, Fernando Garnacho, Armando Rodrigo Mor, Thanh Vu-Cong

    Driven by the voltage increase in high-voltage direct current (HVDC) Gas-insulated substations (GIS), novel methods are needed for partial discharge (PD) detection and monitoring. This paper shows a PD calibration method for very-high frequency magnetic and electric sensors in GIS. The calibration method uncertainty is tested in three laboratories using a low-voltage (LV) test bench and a high-voltage (HV) full-scale GIS. In the LV test, the calibration method’s linearity, signal-to-noise ratio, and pulse width were compared against a reference charge, resulting in an error of around ±10%. The HV test consisted of different artificial defects introduced in a full-scale GIS, resulting in errors of around ±30%. The uncertainty is attributed mainly to random noise, which is critical in the charge estimation method. The electric and magnetic sensor combination showed better results, especially in the full-scale GIS, where reflections play an important role. This research has been performed in the framework of the project Future Energy 19ENG02 of EURAMET, resulting in a calibration method with the potential to measure PD pulses and discriminate impulse interferences, giving an advantage over conventional and ultra-high frequency methods.


  • Partial discharge measurement in DC GIS: comparison between conventional and UHF methods

    by T. Vu-Cong, M. Dalstein, C. Toigo, F. Jacquier, A. Girodet

    The detection, identification and localization of defects are essential to ensure the service reliability of Gas Insulated Switchgear (GIS). Partial discharge (PD) measurement is well-known as one of the most effective technique for defect detection and identification in electrical insulation systems. PD measurement according to IEC standard 60270 is known as the conventional technique, in which PD is quantified in terms of apparent charge. Moreover, non-conventional technique, like UHF detection, can also be used for partial discharge measurement to enhance the signal/noise ratio in GIS. For AC electrical insulating systems both techniques are effectives, widely used and give the same signature of defect. Unfortunately, very little information is available for DC systems, especially regarding the comparison of the defect fingerprint between the two methods. The aim of this paper is to investigate the partial discharge signals recorded with both conventional and UHF methods in DC voltage. The results showed that the defect fingerprints are similar between the conventional measurement and the UHF measurement, regardless the UHF antenna position in the equipment.