Thanh Vu-Cong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thanh Vu-Cong has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Claire Jean-Mistral
Univ. of Lyon (France)
9 shared publications - Alain Sylvestre
University Grenoble Alpes, CNRS, Grenoble INP, G2Elab, Grenoble 38000, France
8 shared publications A. Girodet
2 shared publications- Alain Girodet
SuperGrid Institute, Lyon, France
2 shared publications L. Zavattoni
2 shared publications- Matthieu Dalstein
SuperGrid Institute, 23 rue Cyprian, Villeurbanne, France
2 shared publications
Latest Publications
- 11 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (19) , 23486-23493
Methods for Partial Discharge Calibration in Gas-Insulated Substations for HVDC Power Grids and Charge Evaluation Uncertainty
Driven by the voltage increase in high-voltage direct current (HVDC) Gas-insulated substations (GIS), novel methods are needed for partial discharge (PD) detection and monitoring. This paper shows a PD calibration method for very-high frequency magnetic and electric sensors in GIS. The calibration method uncertainty is tested in three laboratories using a low-voltage (LV) test bench and a high-voltage (HV) full-scale GIS. In the LV test, the calibration method’s linearity, signal-to-noise ratio, and pulse width were compared against a reference charge, resulting in an error of around ±10%. The HV test consisted of different artificial defects introduced in a full-scale GIS, resulting in errors of around ±30%. The uncertainty is attributed mainly to random noise, which is critical in the charge estimation method. The electric and magnetic sensor combination showed better results, especially in the full-scale GIS, where reflections play an important role. This research has been performed in the framework of the project Future Energy 19ENG02 of EURAMET, resulting in a calibration method with the potential to measure PD pulses and discriminate impulse interferences, giving an advantage over conventional and ultra-high frequency methods.
- 11 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (19) , 23486-23493
Methods for Partial Discharge Calibration in Gas-Insulated Substations for HVDC Power Grids and Charge Evaluation Uncertainty
Driven by the voltage increase in high-voltage direct current (HVDC) Gas-insulated substations (GIS), novel methods are needed for partial discharge (PD) detection and monitoring. This paper shows a PD calibration method for very-high frequency magnetic and electric sensors in GIS. The calibration method uncertainty is tested in three laboratories using a low-voltage (LV) test bench and a high-voltage (HV) full-scale GIS. In the LV test, the calibration method’s linearity, signal-to-noise ratio, and pulse width were compared against a reference charge, resulting in an error of around ±10%. The HV test consisted of different artificial defects introduced in a full-scale GIS, resulting in errors of around ±30%. The uncertainty is attributed mainly to random noise, which is critical in the charge estimation method. The electric and magnetic sensor combination showed better results, especially in the full-scale GIS, where reflections play an important role. This research has been performed in the framework of the project Future Energy 19ENG02 of EURAMET, resulting in a calibration method with the potential to measure PD pulses and discriminate impulse interferences, giving an advantage over conventional and ultra-high frequency methods.
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (6) , 2294-2302
Long-Term Partial Discharge Behavior of Protrusion Defect in HVDC GIS
This paper investigates partial discharge (PD) behavior of protrusion defects in real size High Voltage Direct Current Gas Insulated Switchgear (HVDC GIS) for SF 6 and SF 6 alternative gases including Fluoronitrile – CO 2 mixture (10 %) and Fluoroketone – Dry Air mixture (6.6 %). The evolution of PD apparent charge and PD repetition rate for all investigated gases is presented and discussed. The measurement results indicate that PD behavior changes as a function of time. The PD apparent charge increases and the PD repetition rate decreases with the increase of voltage application time. This evolution can be related to the change in protrusion tip radius due to electrochemical etching: Radius of the protrusion’s tip being enlarged. Additionally, the Pulse Sequence Analysis (PSA) plots of the PDs caused by this defect are presented. It is observed that the PSA plots change over time. Therefore, for the development of a robust PD monitoring and defect recognition tool, as well as for the assessment of risks in the operation of HVDC GIS, it is crucial to take these changes into account.
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (6) , 2294-2302
Long-Term Partial Discharge Behavior of Protrusion Defect in HVDC GIS
This paper investigates partial discharge (PD) behavior of protrusion defects in real size High Voltage Direct Current Gas Insulated Switchgear (HVDC GIS) for SF 6 and SF 6 alternative gases including Fluoronitrile – CO 2 mixture (10 %) and Fluoroketone – Dry Air mixture (6.6 %). The evolution of PD apparent charge and PD repetition rate for all investigated gases is presented and discussed. The measurement results indicate that PD behavior changes as a function of time. The PD apparent charge increases and the PD repetition rate decreases with the increase of voltage application time. This evolution can be related to the change in protrusion tip radius due to electrochemical etching: Radius of the protrusion’s tip being enlarged. Additionally, the Pulse Sequence Analysis (PSA) plots of the PDs caused by this defect are presented. It is observed that the PSA plots change over time. Therefore, for the development of a robust PD monitoring and defect recognition tool, as well as for the assessment of risks in the operation of HVDC GIS, it is crucial to take these changes into account.
- 12 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 607-610
Partial discharge measurement in DC GIS: comparison between conventional and UHF methods
The detection, identification and localization of defects are essential to ensure the service reliability of Gas Insulated Switchgear (GIS). Partial discharge (PD) measurement is well-known as one of the most effective technique for defect detection and identification in electrical insulation systems. PD measurement according to IEC standard 60270 is known as the conventional technique, in which PD is quantified in terms of apparent charge. Moreover, non-conventional technique, like UHF detection, can also be used for partial discharge measurement to enhance the signal/noise ratio in GIS. For AC electrical insulating systems both techniques are effectives, widely used and give the same signature of defect. Unfortunately, very little information is available for DC systems, especially regarding the comparison of the defect fingerprint between the two methods. The aim of this paper is to investigate the partial discharge signals recorded with both conventional and UHF methods in DC voltage. The results showed that the defect fingerprints are similar between the conventional measurement and the UHF measurement, regardless the UHF antenna position in the equipment.
- 12 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 607-610
Partial discharge measurement in DC GIS: comparison between conventional and UHF methods
The detection, identification and localization of defects are essential to ensure the service reliability of Gas Insulated Switchgear (GIS). Partial discharge (PD) measurement is well-known as one of the most effective technique for defect detection and identification in electrical insulation systems. PD measurement according to IEC standard 60270 is known as the conventional technique, in which PD is quantified in terms of apparent charge. Moreover, non-conventional technique, like UHF detection, can also be used for partial discharge measurement to enhance the signal/noise ratio in GIS. For AC electrical insulating systems both techniques are effectives, widely used and give the same signature of defect. Unfortunately, very little information is available for DC systems, especially regarding the comparison of the defect fingerprint between the two methods. The aim of this paper is to investigate the partial discharge signals recorded with both conventional and UHF methods in DC voltage. The results showed that the defect fingerprints are similar between the conventional measurement and the UHF measurement, regardless the UHF antenna position in the equipment.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 93-96
Surface charge measurements on epoxy spacer in HVDC GIS/GIL in SF6
The design of reliable high voltage equipment remains a challenge nowadays. The surface charge accumulation at gas/solid interface is a major problem for HVDC GIS/GIL. The electric field can be distorted and the dielectric strength of the system can be thus reduced dramatically due to surface charges. This paper presents the measurement of surface charge (surface potential) on spacer in DC GIS/GIL under pressurized SF6 condition. The surface potential distribution on the spacer is obtained by an electrostatic probe connected to a displacement system. Firstly, the importance of preparation process for DC GIS/GIL spacer for the measurement of surface charge is introduced. The influence of DC voltage, electrode roughness on the surface charge accumulation and the time constant of the system is then investigated. The dominant mechanism for surface charge accumulation is also identified.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 93-96
Surface charge measurements on epoxy spacer in HVDC GIS/GIL in SF6
The design of reliable high voltage equipment remains a challenge nowadays. The surface charge accumulation at gas/solid interface is a major problem for HVDC GIS/GIL. The electric field can be distorted and the dielectric strength of the system can be thus reduced dramatically due to surface charges. This paper presents the measurement of surface charge (surface potential) on spacer in DC GIS/GIL under pressurized SF6 condition. The surface potential distribution on the spacer is obtained by an electrostatic probe connected to a displacement system. Firstly, the importance of preparation process for DC GIS/GIL spacer for the measurement of surface charge is introduced. The influence of DC voltage, electrode roughness on the surface charge accumulation and the time constant of the system is then investigated. The dominant mechanism for surface charge accumulation is also identified.
- 23 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 320, 860-863
Leakage current measurements in Direct Current Gas Insulated Substations equipment
Charge accumulation on solid insulator in Gas Insulated Substation (GIS) is one of the major issues under Direct Current (DC). A specific device has been developed in order to assess the origin of such charges within SF6, in a coaxial geometry. Current measurements have been performed at different pressures (0.2 - 0.5 MPa), using electric field ranging from 2 to 10 kV/mm and for various water content of gas. The results evidenced that non negligible current passes through the gas. It strongly suggests that charges are emitted from the high voltage electrode. Moreover, this emission is influenced by the water content in the device.
- 23 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 320, 860-863
Leakage current measurements in Direct Current Gas Insulated Substations equipment
Charge accumulation on solid insulator in Gas Insulated Substation (GIS) is one of the major issues under Direct Current (DC). A specific device has been developed in order to assess the origin of such charges within SF6, in a coaxial geometry. Current measurements have been performed at different pressures (0.2 - 0.5 MPa), using electric field ranging from 2 to 10 kV/mm and for various water content of gas. The results evidenced that non negligible current passes through the gas. It strongly suggests that charges are emitted from the high voltage electrode. Moreover, this emission is influenced by the water content in the device.
- 1 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21596247,p. 1430-1435
Modelling of soft generator combining electret and dielectric elastomer
Dielectric elastomer generators (DEGs) are a promising technology for soft applications involving fluid or human interactions thanks to their high energy density and ability to couple directly on mechanical ambient sources. Electret can be used to replace the high external voltage source necessary to this electrostatic generator. These soft hybrid generators require thus a reliable non-linear multi-physic models to estimate their performances and to design new innovative structure. We present here an analytic and numeric model for structures combining dielectric elastomer and electrets.
- 1 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21596247,p. 1430-1435
Modelling of soft generator combining electret and dielectric elastomer
Dielectric elastomer generators (DEGs) are a promising technology for soft applications involving fluid or human interactions thanks to their high energy density and ability to couple directly on mechanical ambient sources. Electret can be used to replace the high external voltage source necessary to this electrostatic generator. These soft hybrid generators require thus a reliable non-linear multi-physic models to estimate their performances and to design new innovative structure. We present here an analytic and numeric model for structures combining dielectric elastomer and electrets.
- 8 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9056, 90561P-90561P-8
How does static stretching decrease the dielectric constant of VHB 4910 elastomer?
- 8 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9056, 90561P-90561P-8
How does static stretching decrease the dielectric constant of VHB 4910 elastomer?
- 19 September 2013
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 22 (10) , 104017
On the power management and electret hybridization of dielectric elastomer generators
Dielectric elastomer generators offer great potential for applications involving human or fluid interaction. Nevertheless, they are passive materials requiring to be poled by a high external bias voltage or by electronic power circuits. These power circuits complicate the system drastically and have slowed down the development of dielectric elastomer generators. Replacing the high-voltage source by an electret is a promising alternative, leading to simple flexible generators. In this paper, after a brief review of the classic electronic circuits used to supply dielectric elastomer generators, we present a complete theoretical study on a new hybridization: named the ‘edge mode’. In this mode, we prove the feasibility of flexible 2D autonomous dielectric generators using the edge effects of the electric field induced by electrets (Teflon) to polarize a dielectric elastomer (Danfoss Polypower). To this end, different 2D structures were modelled as a function of various geometric parameters of the structure. After these structures were subjected to a strain of 50%, a scavenged energy of a few μJ g−1 can be obtained.
- 19 September 2013
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 22 (10) , 104017
On the power management and electret hybridization of dielectric elastomer generators
Dielectric elastomer generators offer great potential for applications involving human or fluid interaction. Nevertheless, they are passive materials requiring to be poled by a high external bias voltage or by electronic power circuits. These power circuits complicate the system drastically and have slowed down the development of dielectric elastomer generators. Replacing the high-voltage source by an electret is a promising alternative, leading to simple flexible generators. In this paper, after a brief review of the classic electronic circuits used to supply dielectric elastomer generators, we present a complete theoretical study on a new hybridization: named the ‘edge mode’. In this mode, we prove the feasibility of flexible 2D autonomous dielectric generators using the edge effects of the electric field induced by electrets (Teflon) to polarize a dielectric elastomer (Danfoss Polypower). To this end, different 2D structures were modelled as a function of various geometric parameters of the structure. After these structures were subjected to a strain of 50%, a scavenged energy of a few μJ g−1 can be obtained.
- 9 April 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8687, 86871S-86871S-13
New operating limits for applications with electroactive elastomer: effect of the drift of the dielectric permittivity and the electrical breakdown
- 9 April 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8687, 86871S-86871S-13
New operating limits for applications with electroactive elastomer: effect of the drift of the dielectric permittivity and the electrical breakdown