XHXiaoyi Hu

Xiaoyi Hu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaoyi Hu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessing the Seismic Performance of Prefabricated Coupling Beams Using Double-Lap Sleeves: An Experimental and Numerical Investigation

    by Mei Jin, Hao Wu, Lei Su, Xiaoyi Hu, Yong Zeng, Qiang Cai, Wenju Yang

    To advance the application of prefabricated structures, this study proposes a novel sleeve connection for reinforced concrete coupling beams, aiming to balance the construction efficiency with seismic performance in prefabricated structures. Quasi-static tests and numerical simulations were conducted, investigating the effects of span-to-depth ratio, connection type, and casting method. The experimental results demonstrate that the proposed sleeve-connected beams exhibit seismic performance comparable to, and in some cases superior to, their cast-in-place counterparts. Specifically, the prefabricated specimen with a span-to-depth ratio of 4 achieved approximately 85% of the energy dissipation capacity of its cast-in-place counterpart. However, as the span-to-depth ratio decreased, the energy dissipation capacity of the prefabricated beams increased significantly, reaching up to 2.5 times that of the cast-in-place specimens. Numerical simulations, which showed good agreement with experimental results in terms of failure modes and hysteresis curves, further revealed that concrete compressive strength has a limited influence on seismic behavior. In contrast, increasing the reinforcement ratio effectively improved stiffness and ductility. Notably, increasing the rebar diameter from 18 mm to 22 mm resulted in approximately 25% improvement in energy dissipation capacity. The findings provide novel insights and a scientific basis for the practical application of this innovative prefabricated solution.


  • Open Access

    Experimental Study on Seismic Performance of Prefabricated Columns Connected Using a Novel Dry Sleeve

    by Xiaoyi Hu, Baojun Zhao, Hao Wu, Abderrahim Djerrad, Dekai Zhang

    Prefabricated structures are widely used because of their advantages of energy savings, environmental protection, standardization, and universality. However, due to the complex structure of the joints, it is easy to make the joint installation difficult and the prefabricated column connection unreliable, and further lead to the poor seismic performance of the structure. Therefore, a new type of dry sleeve joint with double screw sleeve without support is proposed, and the seismic performance and influencing factors of the new dry-sleeve-joint prefabricated column are studied. This study encompasses seven reinforced concrete columns characterized by cross-sectional dimensions of 600 mm × 600 mm. Among these, five specimens feature a novel dry sleeve connection, while the remaining two specimens were entirely cast-in-place. Low-cycle reversed loading experiments were conducted on all specimens to analyze and compare the damage patterns, hysteresis curves, skeleton curves, displacement ductility, energy dissipation capacity, and ultimate bearing capacity between precast and cast-in-place columns. Several parameters, including fabrication method, axial compression ratio, longitudinal reinforcement diameter, and hoop spacing, were examined. The findings demonstrated that the calculated-to-tested ratio of the ultimate bearing capacity for the prefabricated specimens was determined to be 0.62, indicating a high level of safety. The displacement ductility coefficient for each specimen ranged from 2.43 to 3.31, while the ultimate drift ratio was within the range of 1/41 to 1/33, satisfying the specified requirements for seismic performance. However, the hysteresis curve of the prefabricated specimens exhibited a pinching effect, which may be related to the existence of a weak layer on the joint surface of the post-cast section. In general, the shape of the new dry sleeve is maintained in the test, the connection form can effectively transfer the force, and the longitudinal bars can be strained and yield when the prefabricated column reaches the peak load. The new type of dry sleeve connection can be used for longitudinal reinforcement connection of reinforced concrete columns with seismic design.


  • Open Access

    Experimental Study on Crack Width of HRB600 Grade High-Strength Steel Bar Reinforced Concrete Beams

    by Xiaoyi Hu, Liang Zeng, Hao Wu, Abderrahim Djerrad, Chenhan Yang, Dekai Zhang

    High-strength reinforcement is an important direction in the development of civil engineering. In order to fill the gap that the current concrete structure code GB50010 has no standard regulations applicable to HRB600-grade high-strength reinforcement, this paper conducted an experimental investigation on the crack width of eight concrete beams reinforced with HRB600-grade high-strength reinforcement. The study examined various parameters to understand the crack development process, crack spacing, and factors influencing crack width in the pure bending section. The results revealed that the damage mode and crack development process of high-strength reinforced concrete beams were similar to those observed in ordinary reinforced concrete bending members. The crack spacing in the pure bending section was independent of the concrete strength, and the average crack width in the pure bending section exhibited a proportional relationship with the reinforcement strain. Moreover, both were mathematically related to the ratio of reinforcement diameter and ratio. A calculation formula for the maximum crack width suitable for HRB600-grade reinforced concrete beams was developed and fit. The HRB600-grade high-strength reinforcement had an obvious yield stage and good ductility, and the test study provides a powerful reference for promoting the application of high-strength reinforcement in concrete structures.