Effects of skin tone on photoacoustic imaging and oximetry
Open Access
- 20 December 2023
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S1) , S11506-17
Abstract
Photoacoustic imaging (PAI) is an emerging molecular imaging modality that provides contrast based on the absorption of light by different molecules (chromophores) in tissue. These molecules may be endogenous, such as hemoglobin, melanin, lipids and water, or exogenous, covering a range of contrast agents.1,2 PAI has the potential to recover the concentration of each of these chromophores based on their unique optical absorption spectra, by acquiring data at multiple wavelengths and subjecting the reconstructed images to multispectral processing methods.3 For example, the recovery of relative concentrations of oxy- and deoxy-hemoglobin is commonly used to derive oxygenation maps from PAI with linear spectral unmixing.4 Obtaining accurate maps of chromophore concentrations, however, is limited by spatial variations in light fluence, which are significant at depth and are highly dependent on the surrounding distribution of optical absorbers and scatterers.3 This is often referred to as ‘spectral coloring’. Several factors can affect tissue optical properties, including age,5 low blood perfusion,6 or skin tone,7 which consequently affect the ability to extract quantitative information from PAI.Keywords
All Related Versions
This publication has 51 references indexed in Scilit:
- Biomedical photoacoustic imagingInterface Focus, 2011
- Implementing and Validating Transcutaneous Bilirubinometry for NeonatesAmerican Journal of Clinical Pathology, 2009
- Dark Skin Decreases the Accuracy of Pulse Oximeters at Low Oxygen Saturation: The Effects of Oximeter Probe Type and GenderAnesthesia & Analgesia, 2007
- Detection of hyperbilirubinaemia in jaundiced full-term neonates by eye or by bilirubinometer?European Journal of Pediatrics, 2004
- The evolution of human skin colorationJournal of Human Evolution, 2000
- Effect of Skin Pigmentation on Pulse Oximetry Accuracy in the Emergency DepartmentAcademic Emergency Medicine, 1998
- Refractive Index of the Human Lens Surface Measured with an Optic Fibre SensorOphthalmic Research, 1994
- Determining the optical properties of turbid media by using the adding–doubling methodApplied Optics, 1993
- Skin colour typology and suntanning pathwaysInternational Journal of Cosmetic Science, 1991
- Reliability of Pulse Oximetry in Titrating Supplemental Oxygen Therapy in Ventilator-Dependent PatientsChest, 1990