RTRan Tao

Ran Tao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ran Tao has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Spectral characterisation of short-wave infrared (SWIR) tissue chromophores and tissue-mimicking phantom optical properties

    by Melissa J Watt, Layla Malouf, Ran Tao, Isabelle Racicot, Thomas R Else, Janek Groehl, Sarah E Bohndiek

    Significance Short-wave infrared (SWIR) sensors promise to expand the capabilities of optical sensing technologies, but the lack of robust data characterising tissue-constituent optical properties in the SWIR makes instrument design challenging. Aim We characterise and evaluate the optical properties of the dominant chromophores in tissue and tissue- mimicking phantoms, from visible to SWIR wavelengths. Approach Using single-integrating sphere systems, we measured the optical properties of single-component chromophores (H2O, haemoglobin, corn oil, synthetic melanin) and multi-component tissues (whole blood, lard), to decouple contributions from optical scattering, H2O absorption and other contributing chromophores; we also characterised commonly-used phantom materials and investigated their potential to mimic soft tissues in the SWIR range using simulations. Results We provide a consistent dataset of absorption and reduced scattering coefficients (µa and µ's) that characterise the dominant tissue chromophores from 450 nm out to 1600 nm. These results were shown to be consistent with literature data, where available. We integrate these data into an open-source Python toolkit, SIMPA, for optical modelling and demonstrate soft tissue simulations that can be probed continuously from visible to SWIR wavelengths. Our findings are compared with tissue-mimicking phantoms, highlighting a need for additives for polymer-based phantoms that mimic SWIR water absorption. Conclusions By providing this open-source dataset, we aim to enable future studies exploring SWIR light-tissue interactions that facilitate rapid assessment and prototyping of next-generation spectroscopy and imaging techniques.

  • Open Access

    Anthropomorphic tissue-mimicking phantoms for oximetry validation in multispectral optical imaging

    by Kris K. Dreher, Janek Gröhl, Friso Grace, Leonardo Ayala, Jan-Hinrich Nölke, Christoph J. Bender, Melissa J. Watt, Katie-Lou White, Ran Tao, Wibke Johnen, et al.

    SignificanceOptical imaging of blood oxygenation (sO2) can be achieved based on the differential absorption spectra of oxy- and deoxyhemoglobin. A key challenge in realizing clinical validation of the sO2 biomarkers is the absence of reliable sO2 reference standards, including test objects.AimTo enable quantitative testing of multispectral imaging methods for assessment of sO2 by introducing anthropomorphic phantoms with appropriate tissue-mimicking optical properties.ApproachWe used the stable copolymer-in-oil base material to create physical anthropomorphic structures and optimized dyes to mimic the optical absorption of blood across a wide spectral range. Using 3D-printed phantom molds generated from a magnetic resonance image of a human forearm, we molded the material into an anthropomorphic shape. Using both reflectance hyperspectral imaging (HSI) and photoacoustic tomography (PAT), we acquired images of the forearm phantoms and evaluated the performance of linear spectral unmixing (LSU).ResultsBased on 10 fabricated forearm phantoms with vessel-like structures featuring five distinct sO2 levels (between 0 and 100%), we showed that the measured absorption spectra of the material correlated well with HSI and PAT data with a Pearson correlation coefficient consistently above 0.8. Further, the application of LSU enabled a quantification of the mean absolute error in sO2 assessment with HSI and PAT.ConclusionsOur anthropomorphic tissue-mimicking phantoms hold potential to provide a robust tool for developing, standardising, and validating optical imaging of sO2.


  • Open Access

    Tutorial on phantoms for photoacoustic imaging applications

    by Lina Hacker, James Joseph, Ledia Lilaj, Srirang Manohar, Aoife M. Ivory, Ran Tao, Sarah E. Bohndiek

    Central to the process of successfully translating a novel medical imaging modality lies accurate characterization of device performance and standardization of measurements. For this purpose, test objects with well-defined properties are used to relate a measured imaging signal to the underlying ground-truth property. A subset of these test objects is referred to as tissue-mimicking phantoms, which are artificial objects specifically designed to mimic certain properties of real-world tissues, objects or materials for calibration, testing, and validation purposes. Phantoms are essential to establish consensus performance test methods and support future standards development in biomedical imaging, enabling quality assurance and control as well as performance comparison of different imaging equipment during development and marketing.


  • Open Access

    Tutorial on methods for estimation of optical absorption and scattering properties of tissue

    by Ran Tao, Janek Gröhl, Lina Hacker, Antonio Pifferi, Darren Roblyer, Sarah E. Bohndiek

    SignificanceThe estimation of tissue optical properties using diffuse optics has found a range of applications in disease detection, therapy monitoring, and general health care. Biomarkers derived from the estimated optical absorption and scattering coefficients can reflect the underlying progression of many biological processes in tissues.AimComplex light–tissue interactions make it challenging to disentangle the absorption and scattering coefficients, so dedicated measurement systems are required. We aim to help readers understand the measurement principles and practical considerations needed when choosing between different estimation methods based on diffuse optics.ApproachThe estimation methods can be categorized as: steady state, time domain, time frequency domain (FD), spatial domain, and spatial FD. The experimental measurements are coupled with models of light–tissue interactions, which enable inverse solutions for the absorption and scattering coefficients from the measured tissue reflectance and/or transmittance.ResultsThe estimation of tissue optical properties has been applied to characterize a variety of ex vivo and in vivo tissues, as well as tissue-mimicking phantoms. Choosing a specific estimation method for a certain application has to trade-off its advantages and limitations.ConclusionOptical absorption and scattering property estimation is an increasingly important and accessible approach for medical diagnosis and health monitoring.


  • Open Access

    Targeted multispectral filter array design for the optimization of endoscopic cancer detection in the gastrointestinal tract

    by Michaela Taylor-Williams, Ran Tao, Travis W. Sawyer, Dale J. Waterhouse, Jonghee Yoon, Sarah E. Bohndiek

    SignificanceColor differences between healthy and diseased tissue in the gastrointestinal (GI) tract are detected visually by clinicians during white light endoscopy; however, the earliest signs of cancer are often just a slightly different shade of pink compared to healthy tissue making it hard to detect. Improving contrast in endoscopy is important for early detection of disease in the GI tract during routine screening and surveillance.AimWe aim to target alternative colors for imaging to improve contrast using custom multispectral filter arrays (MSFAs) that could be deployed in an endoscopic “chip-on-tip” configuration.ApproachUsing an open-source toolbox, Opti-MSFA, we examined the optimal design of MSFAs for early cancer detection in the GI tract. The toolbox was first extended to use additional classification models (k-nearest neighbor, support vector machine, and spectral angle mapper). Using input spectral data from published clinical trials examining the esophagus and colon, we optimized the design of MSFAs with three to nine different bands.ResultsWe examined the variation of the spectral and spatial classification accuracies as a function of the number of bands. The MSFA configurations tested showed good classification accuracies when compared to the full hyperspectral data available from the clinical spectra used in these studies.ConclusionThe ability to retain good classification accuracies with a reduced number of spectral bands could enable the future deployment of multispectral imaging in an endoscopic chip-on-tip configuration using simplified MSFA hardware. Further studies using an expanded clinical dataset are needed to confirm these findings.


  • Open Access

    Effects of skin tone on photoacoustic imaging and oximetry

    by Thomas R. Else, Lina Hacker, Janek Gröhl, Ellie V. Bunce, Ran Tao, Sarah E. Bohndiek

    Photoacoustic imaging (PAI) is an emerging molecular imaging modality that provides contrast based on the absorption of light by different molecules (chromophores) in tissue. These molecules may be endogenous, such as hemoglobin, melanin, lipids and water, or exogenous, covering a range of contrast agents.1,2 PAI has the potential to recover the concentration of each of these chromophores based on their unique optical absorption spectra, by acquiring data at multiple wavelengths and subjecting the reconstructed images to multispectral processing methods.3 For example, the recovery of relative concentrations of oxy- and deoxy-hemoglobin is commonly used to derive oxygenation maps from PAI with linear spectral unmixing.4 Obtaining accurate maps of chromophore concentrations, however, is limited by spatial variations in light fluence, which are significant at depth and are highly dependent on the surrounding distribution of optical absorbers and scatterers.3 This is often referred to as ‘spectral coloring’. Several factors can affect tissue optical properties, including age,5 low blood perfusion,6 or skin tone,7 which consequently affect the ability to extract quantitative information from PAI.