  • The Effect of Implant Angle and Ti-Base Abutment Height on Monolithic Zirconia Crown Retention

    by Ceren Kendirli, Hamiyet Güngör, Mehmet Ali Kılıçarslan, Lale Karaağaçlıoğlu

    ObjectiveThis study aimed to investigate the effect of using different ti-base heights on retention in implants placed at 0 degrees and 15 degrees. Material and methods Implant analogs were placed in acrylic blocks at two different angles: 0 degrees and 15 degrees. A total of 60 monolithic zirconia crown specimens were produced, with 15 specimens in each group for 30 specimens with a 5.5 mm ti-base support and 30 specimens with a 3.5 mm ti-base support. After the specimens were cemented to the ti-base supports, they were placed in a universal testing machine for a pull-out test. The maximum force used during cementation failure was recorded in newtons (N). Statistical analysis was performed using Welch's ANOVA test to test for a statistically significant difference in Maximum Load (N) between the four different groups, and the Tamhane T2 post-hoc test analysis was used since variance homogeneity was not achieved. Results There was no statistically significant difference between the straight and angled configurations in the abutment groups with a 3.5 mm Ti-base length (p > 0.05). Apart from the comparison of these two groups, the retention force showed a significant difference between the other group pairs. Conclusions In monolithic zirconia restorations supported by Ti-base abutments used with angled or straight implants, groups with longer Ti-base abutment lengths significantly affected crown retention, while groups with shorter Ti-base abutment lengths did not contribute to crown retention. Considering the prosthetic field, selecting the longest Ti-base support height may minimize the risk of restoration dislodgement.

  • Open Access

    Mechanical and surface properties of resin-based materials for permanent use fabricated by subtractive, additive, and hybrid manufacturing techniques

    by Hande Gultekin, Zeynep Sahin, Lale Karaagaclıoglu

    This in vitro study evaluated the flexural strength, elastic modulus, microhardness, and surface roughness of restorative materials fabricated using subtractive (SM, CAD/CAM milled control), additive (AM-DLP and AM-LCD), and hybrid (HM-LCD) manufacturing approaches. Grandio Disc was used as the reference baseline for the SM group, whereas VarseoSmile TriniQ was used for the AM and HM groups. Additive manufacturing groups included both DLP and LCD technologies to evaluate the influence of printing system. Standardized bar-shaped specimens (25 × 2 × 2 mm) were prepared according to ISO 4049:2019 for flexural testing, while disk-shaped specimens (15 mm in diameter × 1 mm in thickness) were used for Vickers microhardness measurements. Flexural strength, elastic modulus, and microhardness were measured, and surface roughness (Ra, Rz) was assessed. Manufacturing method significantly affected flexural strength, elastic modulus, and microhardness ( p < 0.001), with the SM CAD/CAM control group exhibiting the highest values, followed by AM-LCD and AM-DLP, while the HM-LCD group showed the lowest values. Microhardness was highest in SM, with AM and HM groups showing similar values. Surface roughness (Ra) was higher in the additive groups (AM-DLP: 0.36 ± 0.07 μm; AM-LCD: 0.36 ± 0.01 μm) compared with the SM (0.27 ± 0.04 μm) and HM-LCD (0.29 ± 0.04 μm) groups. For Rz, the additive manufacturing groups showed higher values than the HM-LCD group ( p < 0.05), whereas no significant differences were observed between the SM group and either the additive or hybrid groups. Both manufacturing method and material-related factors influenced the mechanical and surface properties of resin-based restorative materials. The SM group served as a clinically relevant reference baseline, while the inclusion of two different printing technologies allowed a comprehensive comparison of vat-photopolymerization systems.

  • Open Access

    Üç Farklı Yöntemle Üretilen Okluzal Splint Materyallerinin Kırılma Dayanımlarının Karşılaştırılması: İn-Vitro Çalışma

    by Şeyma Yavuz, Elif Tuba Akçin, Lale Karaağaçlıoğlu

    Amaç: Bu çalışmanın amacı, üç farklı üretim yöntemiyle hazırlanan oklüzal splint materyallerinin kırılma dayanımlarını karşılaştırmaktır. Gereç ve Yöntem: Dijital ortamda tasarlanan 10×10×2 mm boyutlarındaki örnekler; konvansiyonel (manuel olarak otopolimerizan akrilik ile), eksiltmeli (frezelenmiş PMMA bloklarla) ve eklemeli (DLP teknolojisiyle fotopolimer reçinelerden) yöntemlerle üretilmiştir (n=25). Her üretim sürecinde destek yapılar uzaklaştırılmış, yüzey işlemleri standart hale getirilmiştir. Kırılma dayanımı testleri, 3 mm çapındaki paslanmaz çelik düz kompresyon başlığı ve 1 mm/dk hızla çalışan universal test cihazı kullanılarak yapılmıştır. Tüm testler aynı operatör tarafından, sabit çevresel koşullarda gerçekleştirilmiştir. Maksimum kırılma kuvveti Newton cinsinden kaydedilmiştir. Veriler Shapiro-Wilk testi ile değerlendirilmiş, gruplar arası farklar Kruskal-Wallis testi ve Bonferroni düzeltmeleriyle analiz edilmiştir. Bulgular: Eksiltmeli üretim yöntemi en yüksek kırılma dayanımını göstermiş, bunu eklemeli ve konvansiyonel yöntem izlemiştir (P

  • Open Access

    Implant Body Fracture Due to Fatigue in a Maxillary Implant‐Retained Overdenture Treatment

    by Hakan Terzioğlu, Can Hakan Sarıkaya, Rıza Gürbüz, Lale Karaağaçlıoğlu

    The aim of this study was to determine the causes of fatigue and implant failures in an implant‐retained overdenture case. One out of four implants portrayed inadequate osseointegration during healing abutment placement, and one was fractured from the middle to the apical third after 1 year of denture use. Various aspects, such as insufficient cooling while implant socket preparation, incorrect prosthodontic planning, and erroneous design of the denture, were evaluated. Macroscopic and microscopic inspections of the fractured implant body were assessed by scanning electron microscopy (SEM) and optical microscopy. Consequently, metallic fatigue along with secondary cracks and beach marks were evident. It was deduced that the failed and fractured implants depicted substandard osseointegration; thus, they were susceptible to the wear out effect of the occlusal forces. Unfavorable osseointegration caused the fulcrum axis to move apically instead of forming on the neck part of the implant, and micromovements around the fulcrum axis mustered the fracture.

  • Open Access

    The impact of different surface treatments on repair bond strength of conventionally, subtractive‐, and additive‐manufactured denture bases

    by Zeynep Sahin, Nazire Esra Ozer, Tamer Akan, Mehmet Ali Kılıcarslan, Lale Karaagaclıoglu

    Objective This study aimed to examine the shear bond strength (SBS) of repair material to conventionally, subtractive-, and additive-manufactured denture bases after different surface treatments. Materials and Methods Disk-shaped test specimens (N = 300) were prepared from denture base materials produced by one conventional (Procryla), one subtractive (Yamahachi), and one additive (Curo Denture) method. The test specimens were randomly divided into five groups (n = 10) and exposed to a variety of surface treatments-Group A: no surface treatment; Group B: grinding with silicon carbide paper; Group C: sandblasting; Group D: erbium: yttrium-aluminum-garnet laser; and Group E: plasma. Repair was performed with autopolymerizing acrylic resin (Meliodent). Surface roughness analyses were performed with a profilometer. Scanning electron microscopy was used to examine one specimen from each subgroup. SBS was evaluated on a universal testing machine. Failure types were observed under a stereomicroscope. Results Surface roughness values were significantly higher in all test materials in Group D than in the other groups (p < 0.001). For conventional resin, the SBS values were higher in Group C than in Groups A, D, and E (p < 0.001). For CAD/CAM material, Groups B and C had significantly greater SBS increases compared with Group E (p < 0.001). For 3D material, Group D showed higher SBS than all groups except Group C (p < 0.001). Conclusions For SBS, sandblasting was most effective in the conventional group, whereas laser treatment was the most effective in the additive-manufactured group. For the subtractive group, surface treatments other than plasma exhibited similar SBS. Clinical Significance In repairing fractured prostheses, any degree of roughening suitable for the material content may provide an SBS benefit.


  • The effect of various surface treatments on the repair bond strength of denture bases produced by digital and conventional methods

    by Zeynep Sahin, Nazire Esra Ozer, Tamer Akan, Mehmet Ali Kılıcarslan, Lale Karaagaclıoglu

    There is limited information on the repairability of prostheses produced with digital technology. This study aims to evaluate various surface treatments on flexural bond strength of repaired dentured base resins produced by digital and conventional methods. A total of 360 samples were prepared from one heat-polymerized, one CAD/CAM milled and one 3D printed denture base materials. All of the test samples were subjected to thermocycling (5–55 °C, 5000 cycles) before and after repair with auto-polymerizing acrylic resin. The test samples were divided into five subgroups according to the surface treatment: grinding with silicon carbide (SC), sandblasting with Al2O3 (SB), Er:YAG laser (L), plasma (P) and negative control (NC) group (no treatment). In addition, the positive control (PC) group consisted of intact samples for the flexural strength test. Surface roughness measurements were performed with a profilometer. After repairing the test samples, a universal test device determined the flexural strength values. Both the surface topography and the fractured surfaces of samples were examined by SEM analysis. The elemental composition of the tested samples was analyzed by EDS. Kruskal–Wallis and Mann–Whitney U tests were performed for statistical analysis of data. SB and L surface treatments statistically significantly increased the surface roughness values of all three materials compared to NC subgroups (p < 0.001). The flexural strength values of the PC groups in all three test materials were significantly higher than those of the other groups (p < 0.001). The repair flexural strength values were statistically different between the SC–SB, L–SB, and NC–SB subgroups for the CAD/CAM groups, and the L–SC and L–NC subgroups for the 3D groups (p < 0.001). The surface treatments applied to the CAD/CAM and heat-polymerized groups did not result in a statistically significant difference in the repair flexural strength values compared to the NC groups (p > 0.05). Laser surface treatment has been the most powerful repair method for 3D printing technique. Surface treatments led to similar repair flexural strengths to untreated groups for CAD/CAM milled and heat-polymerized test samples.