Ceren Kendirli
Research Subjects
Ceren Kendirli has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Hamiyet Güngör Erdoğan
Department of Prosthetic Dentistry Lokman Hekim University Ankara Turkey
1 shared publication - Lale Karaagaclıoglu
Department of Prosthodontics, Faculty of Dentistry, Lokman Hekim University, Ankara, Turkey
1 shared publication - Mehmet Ali Kılıçarslan
Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara 06560, Turkey
1 shared publication
Latest Publications
- 24 June 2026
- Published by Adnan Menderes University in Meandros Medical and Dental Journal
- Vol. 27 (2) , 210-218
The Effect of Implant Angle and Ti-Base Abutment Height on Monolithic Zirconia Crown Retention
ObjectiveThis study aimed to investigate the effect of using different ti-base heights on retention in implants placed at 0 degrees and 15 degrees. Material and methods Implant analogs were placed in acrylic blocks at two different angles: 0 degrees and 15 degrees. A total of 60 monolithic zirconia crown specimens were produced, with 15 specimens in each group for 30 specimens with a 5.5 mm ti-base support and 30 specimens with a 3.5 mm ti-base support. After the specimens were cemented to the ti-base supports, they were placed in a universal testing machine for a pull-out test. The maximum force used during cementation failure was recorded in newtons (N). Statistical analysis was performed using Welch's ANOVA test to test for a statistically significant difference in Maximum Load (N) between the four different groups, and the Tamhane T2 post-hoc test analysis was used since variance homogeneity was not achieved. Results There was no statistically significant difference between the straight and angled configurations in the abutment groups with a 3.5 mm Ti-base length (p > 0.05). Apart from the comparison of these two groups, the retention force showed a significant difference between the other group pairs. Conclusions In monolithic zirconia restorations supported by Ti-base abutments used with angled or straight implants, groups with longer Ti-base abutment lengths significantly affected crown retention, while groups with shorter Ti-base abutment lengths did not contribute to crown retention. Considering the prosthetic field, selecting the longest Ti-base support height may minimize the risk of restoration dislodgement.
- 24 June 2026
- Published by Adnan Menderes University in Meandros Medical and Dental Journal
- Vol. 27 (2) , 210-218
The Effect of Implant Angle and Ti-Base Abutment Height on Monolithic Zirconia Crown Retention
ObjectiveThis study aimed to investigate the effect of using different ti-base heights on retention in implants placed at 0 degrees and 15 degrees. Material and methods Implant analogs were placed in acrylic blocks at two different angles: 0 degrees and 15 degrees. A total of 60 monolithic zirconia crown specimens were produced, with 15 specimens in each group for 30 specimens with a 5.5 mm ti-base support and 30 specimens with a 3.5 mm ti-base support. After the specimens were cemented to the ti-base supports, they were placed in a universal testing machine for a pull-out test. The maximum force used during cementation failure was recorded in newtons (N). Statistical analysis was performed using Welch's ANOVA test to test for a statistically significant difference in Maximum Load (N) between the four different groups, and the Tamhane T2 post-hoc test analysis was used since variance homogeneity was not achieved. Results There was no statistically significant difference between the straight and angled configurations in the abutment groups with a 3.5 mm Ti-base length (p > 0.05). Apart from the comparison of these two groups, the retention force showed a significant difference between the other group pairs. Conclusions In monolithic zirconia restorations supported by Ti-base abutments used with angled or straight implants, groups with longer Ti-base abutment lengths significantly affected crown retention, while groups with shorter Ti-base abutment lengths did not contribute to crown retention. Considering the prosthetic field, selecting the longest Ti-base support height may minimize the risk of restoration dislodgement.