Martina Bastianon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Martina Bastianon has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Davide Esposito
Department of Surgical and Integrated Diagnostic Sciences, University of Genoa, 16132 Genoa, Italy
8 shared publications Giovanni Pratesi
Department of Surgical and Integrated Diagnostic Sciences, University of Genoa, Genoa, Italy
6 shared publicationsCaterina Melani
3 shared publications- Caterina Melani
Clinic of Vascular and Endovascular Surgery, IRCCS Ospedale Policlinico San Martino, Genoa, Italy
3 shared publications Enrica Bosisio
University of Genoa
3 shared publicationsFabio Grimaldi
University of Genoa
3 shared publications
Latest Publications
- 20 April 2026
- Published by SAGE Publications in Journal of Endovascular Therapy
Patient Selection and Technical Considerations for Electrocautery Septotomy in the Management of Aortic Dissection
Objective: Electrocautery septotomy has been proposed as an adjunctive technique during endovascular repair of aortic dissection with the aim of overcoming technical challenges associated with the presence of dual lumen. Methods: We retrospectively analyzed the outcomes of patients treated with electrocautery septotomy, at a single institution, between July 2023 and November 2024. Early outcomes included septotomy technical success, procedural technical success, 30-day mortality, and 30-day major adverse events. Late outcomes included overall survival, positive aortic remodeling, freedom from aortic-related reintervention, and freedom from target vessel instability. Results: Between July 2023 and November 2024, 15 consecutive patients were treated with electrocautery septotomy at a single center. The underlying disease was chronic dissection in 13 patients (86.6%), subacute residual aortic dissection in 1 patient (6.7%), and acute type B dissection in 1 patient (6.7%). The primary indication for treatment was a maximum aortic diameter ≥5.5 cm in 8 patients (53.3%) and urgent repair in 7 patients (46.7%) due to pain in 4 patients (26.6%), malperfusion in 2 patients (13.3%), and aortic rupture in 1 patient (6.7%). Septotomy technical success was obtained in all the patients (100%), with full expansion of the true lumen. No aortic lesions, target vessels occlusion, or distal embolization were reported. Procedural technical success was 86.7%. Peri-operative major adverse events occurred in 3 patients (20%), with 1 death (6.7%). During follow-up, 1 additional non-aorta-related death was registered, and 2 reinterventions were performed. Positive aortic remodeling was observed in 78.6% of patients. Conclusions: Electrocautery septotomy results in being valuable technique to address technical challenges in the endovascular treatment of postdissection thoracoabdominal aneurysms. Careful patient selection and tailored technical adjustments can further enhance the procedure success. Clinical Impact: This study contributes to the growing body of evidence supporting electrocautery septotomy as a effective adjuntive technique during endovascular repair of post-dissection thoraco-abdominal aneurysm. However, it also underscores the limitations related to patient selection, highlighting the importance of careful pre-procedural evaluation to identify appropriate candidates and optimize clinical outcomes.
- 20 April 2026
- Published by SAGE Publications in Journal of Endovascular Therapy
Patient Selection and Technical Considerations for Electrocautery Septotomy in the Management of Aortic Dissection
Objective: Electrocautery septotomy has been proposed as an adjunctive technique during endovascular repair of aortic dissection with the aim of overcoming technical challenges associated with the presence of dual lumen. Methods: We retrospectively analyzed the outcomes of patients treated with electrocautery septotomy, at a single institution, between July 2023 and November 2024. Early outcomes included septotomy technical success, procedural technical success, 30-day mortality, and 30-day major adverse events. Late outcomes included overall survival, positive aortic remodeling, freedom from aortic-related reintervention, and freedom from target vessel instability. Results: Between July 2023 and November 2024, 15 consecutive patients were treated with electrocautery septotomy at a single center. The underlying disease was chronic dissection in 13 patients (86.6%), subacute residual aortic dissection in 1 patient (6.7%), and acute type B dissection in 1 patient (6.7%). The primary indication for treatment was a maximum aortic diameter ≥5.5 cm in 8 patients (53.3%) and urgent repair in 7 patients (46.7%) due to pain in 4 patients (26.6%), malperfusion in 2 patients (13.3%), and aortic rupture in 1 patient (6.7%). Septotomy technical success was obtained in all the patients (100%), with full expansion of the true lumen. No aortic lesions, target vessels occlusion, or distal embolization were reported. Procedural technical success was 86.7%. Peri-operative major adverse events occurred in 3 patients (20%), with 1 death (6.7%). During follow-up, 1 additional non-aorta-related death was registered, and 2 reinterventions were performed. Positive aortic remodeling was observed in 78.6% of patients. Conclusions: Electrocautery septotomy results in being valuable technique to address technical challenges in the endovascular treatment of postdissection thoracoabdominal aneurysms. Careful patient selection and tailored technical adjustments can further enhance the procedure success. Clinical Impact: This study contributes to the growing body of evidence supporting electrocautery septotomy as a effective adjuntive technique during endovascular repair of post-dissection thoraco-abdominal aneurysm. However, it also underscores the limitations related to patient selection, highlighting the importance of careful pre-procedural evaluation to identify appropriate candidates and optimize clinical outcomes.
- 23 March 2026
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 34 (4) , 355-362
Endovascular aortic repair with the custom-made cook fenestrated device for the treatment of complex abdominal aortic aneurysms
Background: Fenestrated endovascular aneurysm repair (FEVAR) has become an essential option for the treatment of complex abdominal aortic aneurysms (AAA). While technological advances and growing operator experience have expanded its applicability, outcomes remain heterogeneous across centers and patient subsets. Evaluating real-world results is crucial to better define the effectiveness, safety, and durability of FEVAR in current practice. Methods: This is a single-center, retrospective, observational study. Consecutive patients treated with FEVAR for complex AAA with a custom-made Cook device from January 2015 to October 2025 were included. Outcomes accessed included technical success, early major systemic complications, overall survival, freedom from reinterventions, target vessel instability, endoleaks, and sac expansion. Results: Sixty-four consecutive patients were treated with FEVAR Cook, of which 23 (35.9%) for juxtarenal AAA, 35 (54.7%) pararenal AAA and 6 (9.4%) thoraco-abdominal type IV aortic aneurysm. All but three patients were treated electively (95.3%). Two hundred twenty-two target vessels were successfully cannulated and treated with a bridging stent. Technical success was 98.4%. Early major systemic complications rate was 14.1%. Median follow-up was 29.5 months (IQR 47). Overall survival estimates at 1 and 4 years were 86.9% and 71.3%, respectively. Estimates at 4 years of freedom from reinterventions and target vessel instability were 90.9% and 93.8%, respectively. Freedom from type I/Ic and III/IIIc endoleak was 95.3% at 4 years. Sac regression, stability, and expansion at follow-up occurred in 29.5%, 63.9%, and 6.6%, respectively. Conclusions: FEVAR emerges as an appropriate and effective treatment option for complex aortic aneurysms. In our experience, the procedure provides high technical success and durable target-vessel preservation, with very satisfactory outcomes even at mid- to long-term follow-up.
- 23 March 2026
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 34 (4) , 355-362
Endovascular aortic repair with the custom-made cook fenestrated device for the treatment of complex abdominal aortic aneurysms
Background: Fenestrated endovascular aneurysm repair (FEVAR) has become an essential option for the treatment of complex abdominal aortic aneurysms (AAA). While technological advances and growing operator experience have expanded its applicability, outcomes remain heterogeneous across centers and patient subsets. Evaluating real-world results is crucial to better define the effectiveness, safety, and durability of FEVAR in current practice. Methods: This is a single-center, retrospective, observational study. Consecutive patients treated with FEVAR for complex AAA with a custom-made Cook device from January 2015 to October 2025 were included. Outcomes accessed included technical success, early major systemic complications, overall survival, freedom from reinterventions, target vessel instability, endoleaks, and sac expansion. Results: Sixty-four consecutive patients were treated with FEVAR Cook, of which 23 (35.9%) for juxtarenal AAA, 35 (54.7%) pararenal AAA and 6 (9.4%) thoraco-abdominal type IV aortic aneurysm. All but three patients were treated electively (95.3%). Two hundred twenty-two target vessels were successfully cannulated and treated with a bridging stent. Technical success was 98.4%. Early major systemic complications rate was 14.1%. Median follow-up was 29.5 months (IQR 47). Overall survival estimates at 1 and 4 years were 86.9% and 71.3%, respectively. Estimates at 4 years of freedom from reinterventions and target vessel instability were 90.9% and 93.8%, respectively. Freedom from type I/Ic and III/IIIc endoleak was 95.3% at 4 years. Sac regression, stability, and expansion at follow-up occurred in 29.5%, 63.9%, and 6.6%, respectively. Conclusions: FEVAR emerges as an appropriate and effective treatment option for complex aortic aneurysms. In our experience, the procedure provides high technical success and durable target-vessel preservation, with very satisfactory outcomes even at mid- to long-term follow-up.
- Open Access
- 16 July 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (6)
Physician-modified and in situ fenestration for visceral aorta repair: Combine techniques to overcome challenges
- 16 July 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (6)
Open AccessPhysician-modified and in situ fenestration for visceral aorta repair: Combine techniques to overcome challenges
- 3 June 2025
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 67 (6)
Complex endovascular arch repair using fenestrated and branched devices: a single-centre experience
OBJECTIVES: Endovascular arch repair is a reasonable alternative for patients at high risk for open surgery. Despite a reduction in procedural invasiveness, complications remain, particularly in elderly and urgent cases. This study aimed to evaluate our institutional experience at a high-volume aortic center. METHODS: Retrospective, single-center study of endovascular arch repair, along with subgroup analyses for urgent settings, octogenarian patients and graft design. Primary outcomes were technical success, 30-day mortality and morbidity. During follow-up, survival estimation, cumulative incidence of reintervention, endoleak and target vessels instability were evaluated. RESULTS: The study included 74 patients (mean age 72 ± 9 years) treated, between September 2018 and April 2024, with custom-made fenestrated/branched endograft. Technical success was achieved in 93.2% of the patients. Thirty-day mortality in elective setting was 5.4%, and 44.4% in urgent repairs. Major stroke occurred in 6.8% of patients. Urgent repairs showed higher rates of technical failure (22.2 vs 1.8% P < 0.01), 30-day mortality (44.4 vs 5.4%; P < 0.001) and major strokes compared to elective repairs (22.2 vs 1.8%; P < 0.01). Octogenarians had significantly higher 30-day mortality but no difference in major adverse events compared to younger patients (P < 0.01). Branched endografts had higher rates of type Ia endoleaks and reinterventions than fenestrated endografts. At 24 months, the estimated rates were as follows: survival 79% (standard error—SE 0.09), cumulative incidence of reintervention 24% (SE 0.074), endoleak 9% (SE 0.037) and target vessel instability 9% (SE 0.04). CONCLUSIONS: Endovascular arch repair is feasible and yields satisfactory outcomes in high-risk populations, particularly in elective settings. Urgent and elderly patients remain challenging, underscoring the importance of careful patient selection.
- 3 June 2025
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 67 (6)
Complex endovascular arch repair using fenestrated and branched devices: a single-centre experience
OBJECTIVES: Endovascular arch repair is a reasonable alternative for patients at high risk for open surgery. Despite a reduction in procedural invasiveness, complications remain, particularly in elderly and urgent cases. This study aimed to evaluate our institutional experience at a high-volume aortic center. METHODS: Retrospective, single-center study of endovascular arch repair, along with subgroup analyses for urgent settings, octogenarian patients and graft design. Primary outcomes were technical success, 30-day mortality and morbidity. During follow-up, survival estimation, cumulative incidence of reintervention, endoleak and target vessels instability were evaluated. RESULTS: The study included 74 patients (mean age 72 ± 9 years) treated, between September 2018 and April 2024, with custom-made fenestrated/branched endograft. Technical success was achieved in 93.2% of the patients. Thirty-day mortality in elective setting was 5.4%, and 44.4% in urgent repairs. Major stroke occurred in 6.8% of patients. Urgent repairs showed higher rates of technical failure (22.2 vs 1.8% P < 0.01), 30-day mortality (44.4 vs 5.4%; P < 0.001) and major strokes compared to elective repairs (22.2 vs 1.8%; P < 0.01). Octogenarians had significantly higher 30-day mortality but no difference in major adverse events compared to younger patients (P < 0.01). Branched endografts had higher rates of type Ia endoleaks and reinterventions than fenestrated endografts. At 24 months, the estimated rates were as follows: survival 79% (standard error—SE 0.09), cumulative incidence of reintervention 24% (SE 0.074), endoleak 9% (SE 0.037) and target vessel instability 9% (SE 0.04). CONCLUSIONS: Endovascular arch repair is feasible and yields satisfactory outcomes in high-risk populations, particularly in elective settings. Urgent and elderly patients remain challenging, underscoring the importance of careful patient selection.
- Open Access
- 20 May 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (10) , e040911
AhR, IRF5, and HO‐1 Expression in Evaluating Carotid Atherosclerotic Plaque Vulnerability: A Pilot Observational Study
- 20 May 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (10) , e040911
Open AccessAhR, IRF5, and HO‐1 Expression in Evaluating Carotid Atherosclerotic Plaque Vulnerability: A Pilot Observational Study
- Open Access
- 21 April 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
Triple Arch Branch Repair Under Sedo-Analgesia
Purpose: Triple arch branch repair has emerged as a feasible option for high-risk patients unsuitable for open surgery. In high-risk patients, severe pulmonary compromise of pulmonary function due to chronic obstructive pulmonary disease (COPD) can be found. This condition is associated with a higher risk of postoperative complications after general anesthesia and intubation. Clinical Case: In this clinical case, we describe the technical aspects of triple arch branch repair under sedo-analgesia, in a patient with severe COPD, unsuitable for intubation. Precise graft deployment was obtained, and no postoperative complications occurred. Conclusion: Triple arch branch repair under sedo-analgesia emerges as a viable option for high-risk patients with severe pulmonary compromise, obviating the need for general anesthesia and intubation. This clinical case elucidates the procedure, accentuating both its advantages and limitations, while suggesting the necessity for further validation of its safety in future studies. Clinical Impact: The execution of complex endovascular aortic arch repair under sedo-analgesia allows for the expanded applicability of these techniques even in high-risk patients who, due to respiratory issues, cannot undergo general anesthesia and intubation.
- 21 April 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
Open AccessTriple Arch Branch Repair Under Sedo-Analgesia
Purpose: Triple arch branch repair has emerged as a feasible option for high-risk patients unsuitable for open surgery. In high-risk patients, severe pulmonary compromise of pulmonary function due to chronic obstructive pulmonary disease (COPD) can be found. This condition is associated with a higher risk of postoperative complications after general anesthesia and intubation. Clinical Case: In this clinical case, we describe the technical aspects of triple arch branch repair under sedo-analgesia, in a patient with severe COPD, unsuitable for intubation. Precise graft deployment was obtained, and no postoperative complications occurred. Conclusion: Triple arch branch repair under sedo-analgesia emerges as a viable option for high-risk patients with severe pulmonary compromise, obviating the need for general anesthesia and intubation. This clinical case elucidates the procedure, accentuating both its advantages and limitations, while suggesting the necessity for further validation of its safety in future studies. Clinical Impact: The execution of complex endovascular aortic arch repair under sedo-analgesia allows for the expanded applicability of these techniques even in high-risk patients who, due to respiratory issues, cannot undergo general anesthesia and intubation.
- 17 March 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (4) , 2072-2081
Utilizing CO 2 Cone Beam Computed Tomography for Post-Procedure Completion Control Following Fenestrated Endovascular Repair of Complex Aortic Aneurysm With a Standardized CO 2 Protocol
Purpose: To assess the feasibility and efficacy of a standardized CO 2 protocol and CO 2 cone beam computed tomography (CBCT) for procedural completion in fenestrated endovascular aneurysm repair (FEVAR) of complex aortic aneurysms in patients with chronic kidney disease (CKD). Materials and Methods: Ten patients with complex aortic aneurysms and CKD (estimated glomerular filtration rate 2 as the primary contrast agent. Procedures were conducted in a hybrid operating room following a standardized CO 2 protocol with optimized injection parameters and visualization techniques to maximize CO 2 imaging efficacy. CO 2 CBCT was performed intraoperatively to verify stent graft deployment, bridging stent positioning, target vessel patency, and the presence of potential endoleaks. Results: All 10 procedures were completed successfully without intraoperative complications or CO 2 -related adverse effects. Completion CO 2 CBCT provided clear visualization of visceral and renal vessels, and no significant endoleaks were detected. One procedure was entirely iodine contrast-free, while minimal iodine contrast was used in others to address diagnostic uncertainties. Postoperative renal function remained stable across all patients. Conclusion: CO 2 CBCT is a feasible and effective alternative for completion imaging in complex FEVAR procedures for patients with CKD, potentially reducing the need for iodine contrast and the associated risk of nephropathy. A standardized CO 2 protocol can enhance procedural safety. Further research with larger cohorts is needed to confirm these findings. Clinical Impact: CO 2 serves as the preferred contrast medium for the endovascular treatment of patients with iodine contrast allergies or those afflicted with chronic kidney disease (CKD) to preserve further renal deterioration. Ensuring protection from potentially harmful substances is paramount during endovascular repair in such patients. Equally crucial is performing the procedure safely through a standardized protocol and confirming its accuracy upon completion. Nevertheless, the possibility of employing CO 2 for cone beam computed tomography provides invaluable insights into procedural efficacy, thereby enhancing outcomes for CKD patients undergoing complex endovascular repair.
- 17 March 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (4) , 2072-2081
Utilizing CO 2 Cone Beam Computed Tomography for Post-Procedure Completion Control Following Fenestrated Endovascular Repair of Complex Aortic Aneurysm With a Standardized CO 2 Protocol
Purpose: To assess the feasibility and efficacy of a standardized CO 2 protocol and CO 2 cone beam computed tomography (CBCT) for procedural completion in fenestrated endovascular aneurysm repair (FEVAR) of complex aortic aneurysms in patients with chronic kidney disease (CKD). Materials and Methods: Ten patients with complex aortic aneurysms and CKD (estimated glomerular filtration rate 2 as the primary contrast agent. Procedures were conducted in a hybrid operating room following a standardized CO 2 protocol with optimized injection parameters and visualization techniques to maximize CO 2 imaging efficacy. CO 2 CBCT was performed intraoperatively to verify stent graft deployment, bridging stent positioning, target vessel patency, and the presence of potential endoleaks. Results: All 10 procedures were completed successfully without intraoperative complications or CO 2 -related adverse effects. Completion CO 2 CBCT provided clear visualization of visceral and renal vessels, and no significant endoleaks were detected. One procedure was entirely iodine contrast-free, while minimal iodine contrast was used in others to address diagnostic uncertainties. Postoperative renal function remained stable across all patients. Conclusion: CO 2 CBCT is a feasible and effective alternative for completion imaging in complex FEVAR procedures for patients with CKD, potentially reducing the need for iodine contrast and the associated risk of nephropathy. A standardized CO 2 protocol can enhance procedural safety. Further research with larger cohorts is needed to confirm these findings. Clinical Impact: CO 2 serves as the preferred contrast medium for the endovascular treatment of patients with iodine contrast allergies or those afflicted with chronic kidney disease (CKD) to preserve further renal deterioration. Ensuring protection from potentially harmful substances is paramount during endovascular repair in such patients. Equally crucial is performing the procedure safely through a standardized protocol and confirming its accuracy upon completion. Nevertheless, the possibility of employing CO 2 for cone beam computed tomography provides invaluable insights into procedural efficacy, thereby enhancing outcomes for CKD patients undergoing complex endovascular repair.
- 28 February 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (4) , 1737-1744
Electrosurgical In Situ Fenestration of Aortic Endograft
Purpose: Endovascular interventions have become the primary choice for treating complex aortic pathologies, particularly with the use of fenestrated and branched endografts. However, limitations, such as manufacturing time have restricted their applicability in urgent situations. This has led to explore alternative off-the-shelf solutions, including in situ fenestration. Within this technical note, we describe technical aspects of in situ fenestration using electrosurgical guidewire, in both antegrade and retrograde approaches, explaining advantages and limitation compared with other in situ fenestration techniques. Technique: The technique involves standard main body endograft deployment followed by targeted in situ fenestration using an electrified guidewire. Two illustrative cases are presented to demonstrate the technical aspects and clinical outcomes of this procedure. Conclusion: Electrosurgical in situ fenestration emerges as an effective technique for urgent treatment of complex aortic diseases. Further research is warranted to validate its safety and durability in larger patient cohorts. Clinical Impact: Electrosurgical in situ fenestration allows to expand the feasibility of complex endovascular repairs in emegency settings. Electrosurgical in situ fenestration combines the benefits of thermal methods, offering broad availability and lower costs. Compared to other in situ fenestration techniques, the proposed technology allows for the creation of extremely small fenestrations with minimal and precise tissue disruption.
- 28 February 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (4) , 1737-1744
Electrosurgical In Situ Fenestration of Aortic Endograft
Purpose: Endovascular interventions have become the primary choice for treating complex aortic pathologies, particularly with the use of fenestrated and branched endografts. However, limitations, such as manufacturing time have restricted their applicability in urgent situations. This has led to explore alternative off-the-shelf solutions, including in situ fenestration. Within this technical note, we describe technical aspects of in situ fenestration using electrosurgical guidewire, in both antegrade and retrograde approaches, explaining advantages and limitation compared with other in situ fenestration techniques. Technique: The technique involves standard main body endograft deployment followed by targeted in situ fenestration using an electrified guidewire. Two illustrative cases are presented to demonstrate the technical aspects and clinical outcomes of this procedure. Conclusion: Electrosurgical in situ fenestration emerges as an effective technique for urgent treatment of complex aortic diseases. Further research is warranted to validate its safety and durability in larger patient cohorts. Clinical Impact: Electrosurgical in situ fenestration allows to expand the feasibility of complex endovascular repairs in emegency settings. Electrosurgical in situ fenestration combines the benefits of thermal methods, offering broad availability and lower costs. Compared to other in situ fenestration techniques, the proposed technology allows for the creation of extremely small fenestrations with minimal and precise tissue disruption.
- 9 January 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 69 (3) , 405-406
Elevating Endovascular Aortic Aneurysm Repair with Carbon Dioxide: A Step Towards Iodine Free Interventions with Cautionary Advances
- 9 January 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 69 (3) , 405-406
Elevating Endovascular Aortic Aneurysm Repair with Carbon Dioxide: A Step Towards Iodine Free Interventions with Cautionary Advances