CMCaterina Melani

Caterina Melani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Caterina Melani has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Zero Iodine Contrast Endovascular Aortic Repair Using Carbon Dioxide Angiography is Associated with Lower Rates of Renal Deterioration: A Multicentre, Prospective, Propensity Matched Study

    by Emiliano Chisci, Simone Quaglino, Elda Chiara Colacchio, Luca Mezzetto, Roberto Falso, Gioele Simonte, Mauro Gargiulo, Caterina Melani, Tommaso Lazzarotto, Stefano Michelagnoli, et al.

  • Patient Selection and Technical Considerations for Electrocautery Septotomy in the Management of Aortic Dissection

    by Martina Bastianon, Caterina Melani, Davide Esposito, Andrea Sebastiano Savio, Jorge Miguel Mena Vera, Giovanni Pratesi

    Objective: Electrocautery septotomy has been proposed as an adjunctive technique during endovascular repair of aortic dissection with the aim of overcoming technical challenges associated with the presence of dual lumen. Methods: We retrospectively analyzed the outcomes of patients treated with electrocautery septotomy, at a single institution, between July 2023 and November 2024. Early outcomes included septotomy technical success, procedural technical success, 30-day mortality, and 30-day major adverse events. Late outcomes included overall survival, positive aortic remodeling, freedom from aortic-related reintervention, and freedom from target vessel instability. Results: Between July 2023 and November 2024, 15 consecutive patients were treated with electrocautery septotomy at a single center. The underlying disease was chronic dissection in 13 patients (86.6%), subacute residual aortic dissection in 1 patient (6.7%), and acute type B dissection in 1 patient (6.7%). The primary indication for treatment was a maximum aortic diameter ≥5.5 cm in 8 patients (53.3%) and urgent repair in 7 patients (46.7%) due to pain in 4 patients (26.6%), malperfusion in 2 patients (13.3%), and aortic rupture in 1 patient (6.7%). Septotomy technical success was obtained in all the patients (100%), with full expansion of the true lumen. No aortic lesions, target vessels occlusion, or distal embolization were reported. Procedural technical success was 86.7%. Peri-operative major adverse events occurred in 3 patients (20%), with 1 death (6.7%). During follow-up, 1 additional non-aorta-related death was registered, and 2 reinterventions were performed. Positive aortic remodeling was observed in 78.6% of patients. Conclusions: Electrocautery septotomy results in being valuable technique to address technical challenges in the endovascular treatment of postdissection thoracoabdominal aneurysms. Careful patient selection and tailored technical adjustments can further enhance the procedure success. Clinical Impact: This study contributes to the growing body of evidence supporting electrocautery septotomy as a effective adjuntive technique during endovascular repair of post-dissection thoraco-abdominal aneurysm. However, it also underscores the limitations related to patient selection, highlighting the importance of careful pre-procedural evaluation to identify appropriate candidates and optimize clinical outcomes.


  • Utilizing CO 2 Cone Beam Computed Tomography for Post-Procedure Completion Control Following Fenestrated Endovascular Repair of Complex Aortic Aneurysm With a Standardized CO 2 Protocol

    by Davide Esposito, Martina Bastianon, Caterina Melani, Gaddiel Mozzetta, Endri Sila, Fabio Grimaldi, Enrica Bosisio, Andrea Savio, Giuseppe Baldino, Giovanni Pratesi

    Purpose: To assess the feasibility and efficacy of a standardized CO 2 protocol and CO 2 cone beam computed tomography (CBCT) for procedural completion in fenestrated endovascular aneurysm repair (FEVAR) of complex aortic aneurysms in patients with chronic kidney disease (CKD). Materials and Methods: Ten patients with complex aortic aneurysms and CKD (estimated glomerular filtration rate 2 as the primary contrast agent. Procedures were conducted in a hybrid operating room following a standardized CO 2 protocol with optimized injection parameters and visualization techniques to maximize CO 2 imaging efficacy. CO 2 CBCT was performed intraoperatively to verify stent graft deployment, bridging stent positioning, target vessel patency, and the presence of potential endoleaks. Results: All 10 procedures were completed successfully without intraoperative complications or CO 2 -related adverse effects. Completion CO 2 CBCT provided clear visualization of visceral and renal vessels, and no significant endoleaks were detected. One procedure was entirely iodine contrast-free, while minimal iodine contrast was used in others to address diagnostic uncertainties. Postoperative renal function remained stable across all patients. Conclusion: CO 2 CBCT is a feasible and effective alternative for completion imaging in complex FEVAR procedures for patients with CKD, potentially reducing the need for iodine contrast and the associated risk of nephropathy. A standardized CO 2 protocol can enhance procedural safety. Further research with larger cohorts is needed to confirm these findings. Clinical Impact: CO 2 serves as the preferred contrast medium for the endovascular treatment of patients with iodine contrast allergies or those afflicted with chronic kidney disease (CKD) to preserve further renal deterioration. Ensuring protection from potentially harmful substances is paramount during endovascular repair in such patients. Equally crucial is performing the procedure safely through a standardized protocol and confirming its accuracy upon completion. Nevertheless, the possibility of employing CO 2 for cone beam computed tomography provides invaluable insights into procedural efficacy, thereby enhancing outcomes for CKD patients undergoing complex endovascular repair.


  • Electrosurgical In Situ Fenestration of Aortic Endograft

    by Martina Bastianon, Davide Esposito, Caterina Melani, Endri Sila, Giuseppe Baldino, Giovanni Pratesi

    Purpose: Endovascular interventions have become the primary choice for treating complex aortic pathologies, particularly with the use of fenestrated and branched endografts. However, limitations, such as manufacturing time have restricted their applicability in urgent situations. This has led to explore alternative off-the-shelf solutions, including in situ fenestration. Within this technical note, we describe technical aspects of in situ fenestration using electrosurgical guidewire, in both antegrade and retrograde approaches, explaining advantages and limitation compared with other in situ fenestration techniques. Technique: The technique involves standard main body endograft deployment followed by targeted in situ fenestration using an electrified guidewire. Two illustrative cases are presented to demonstrate the technical aspects and clinical outcomes of this procedure. Conclusion: Electrosurgical in situ fenestration emerges as an effective technique for urgent treatment of complex aortic diseases. Further research is warranted to validate its safety and durability in larger patient cohorts. Clinical Impact: Electrosurgical in situ fenestration allows to expand the feasibility of complex endovascular repairs in emegency settings. Electrosurgical in situ fenestration combines the benefits of thermal methods, offering broad availability and lower costs. Compared to other in situ fenestration techniques, the proposed technology allows for the creation of extremely small fenestrations with minimal and precise tissue disruption.