MYMahdieh Yariesbouei
Mahdieh Yariesbouei
*This is an algorithmically generated author record based on publicly available information.
Mahdieh Yariesbouei has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Joost C. Lotters
MESA+ Institute for Nanotechnology, University of Twente, 7522 NB Enschede, The Netherlands
2 shared publications - Remco John Wiegerink
MESA+ Institute, University of Twente, Enschede, The Netherlands
2 shared publications - Maarten Jan Sijmen Bonnema
MESA+ Institute, University of Twente, Enschede, The Netherlands
1 shared publication - Qihui Yu
MESA+ Institute for Nanotechnology, University of Twente, 7522 NH Enschede, The Netherlands
1 shared publication - Remco G. P. Sanders
Integrated Devices and Systems, University of Twente, 7522 NB Enschede, The Netherlands
1 shared publication
Latest Publications
- Open Access
Micro Coriolis Mass Flow Sensor with Large Channel Diameter Realized by HNA Wet Etching
This paper introduces a Coriolis mass flow and density sensor. The sensor is made using Surface Channel Technology (SCT) but with selective wet etching to create the channels. This method forms suspended microfluidic channels with a larger cross-sectional area. Because of this larger cross-sectional area, the sensor has a much higher flow range, up to 50 (for water) with a pressure drop of 1 bar, compared to the standard SCT-based Coriolis sensor, which is only 1.2 . The channel has a semi-elliptical cross-sectional area, measuring 200 micrometers wide and 70 micrometers deep. The channel wall is made of a stack of thin films with a total thickness of 2.5 . Water, isopropyl alcohol (IPA), and nitrogen (N2) are used to test and evaluate the sensor’s mass flow and density sensing performance.Open AccessMicro Coriolis Mass Flow Sensor with Large Channel Diameter Realized by HNA Wet Etching
This paper introduces a Coriolis mass flow and density sensor. The sensor is made using Surface Channel Technology (SCT) but with selective wet etching to create the channels. This method forms suspended microfluidic channels with a larger cross-sectional area. Because of this larger cross-sectional area, the sensor has a much higher flow range, up to 50 (for water) with a pressure drop of 1 bar, compared to the standard SCT-based Coriolis sensor, which is only 1.2 . The channel has a semi-elliptical cross-sectional area, measuring 200 micrometers wide and 70 micrometers deep. The channel wall is made of a stack of thin films with a total thickness of 2.5 . Water, isopropyl alcohol (IPA), and nitrogen (N2) are used to test and evaluate the sensor’s mass flow and density sensing performance. - Open Access
- 10 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 114
Compact Micro-Coriolis Mass-Flow Meter with Optical Readout
This paper presents the first nickel-plated micro-Coriolis mass-flow sensor with integrated optical readout. The sensor consists of a freely suspended tube made of electroplated nickel with a total length of 60 mm, an inner diameter of 580 µm, and a wall thickness of approximately 8 µm. The U-shaped tube is actuated by Lorentz forces. An optical readout consisting of two LEDs and two phototransistors is used to detect the tube motion. Mass-flow measurements were performed at room temperature with water and isopropyl alcohol for flows up to 200 g/h and 100 g/h, respectively. The measured resonance frequencies were 1.67 kHz and 738 Hz for water and 1.70 kHz and 752 Hz for isopropyl alcohol for the twist and swing modes, respectively. The measured phase shift between the two readout signals shows a linear response to mass flow with very similar sensitivities for water and isopropyl alcohol of and , respectively.- 10 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 114
Open AccessCompact Micro-Coriolis Mass-Flow Meter with Optical Readout
This paper presents the first nickel-plated micro-Coriolis mass-flow sensor with integrated optical readout. The sensor consists of a freely suspended tube made of electroplated nickel with a total length of 60 mm, an inner diameter of 580 µm, and a wall thickness of approximately 8 µm. The U-shaped tube is actuated by Lorentz forces. An optical readout consisting of two LEDs and two phototransistors is used to detect the tube motion. Mass-flow measurements were performed at room temperature with water and isopropyl alcohol for flows up to 200 g/h and 100 g/h, respectively. The measured resonance frequencies were 1.67 kHz and 738 Hz for water and 1.70 kHz and 752 Hz for isopropyl alcohol for the twist and swing modes, respectively. The measured phase shift between the two readout signals shows a linear response to mass flow with very similar sensitivities for water and isopropyl alcohol of and , respectively.