Maciej Pikuliński
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maciej Pikuliński has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Zakręcki
AGH University in Krakow, Al. Mickiewicza 30, 30-059 Kraków, Poland;Łukasiewicz Research Network - Industrial Research Institute for Automation and Measurements, Poland
1 shared publication - Daniel Śliż
3rd Department of Internal Medicine and Cardiology, Medical University of Warsaw, 04-749 Warsaw, Poland
1 shared publication - Jan Oleksiuk
Łukasiewicz Research Network—Industrial Research Institute for Automation and Measurements PIAP, 02-486 Warsaw, Poland
1 shared publication - Kajetan Jeznach
Łukasiewicz Research Network–Industrial Research Institute for Automation and Measurements PIAP, 02-486 Warsaw, Poland
1 shared publication - Krzysztof Zawalski
Łukasiewicz Research Network—Industrial Research Institute for Automation and Measurements PIAP, 02-486 Warsaw, Poland
1 shared publication - Paweł Malczyk
Warsaw University of Technology
1 shared publication
Latest Publications
- Open Access
- 12 January 2026
- Published by MDPI AG in Preprints.org
Optimization-Based Design of a Lightweight Rehabilitation Exoskeleton of an Upper Extremity for Task-Oriented Treatment
Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients, neurological, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons - wearable devices mobilizing multiple joints with complex motions representing activities of daily living. To perform the kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology of decreasing the mass of the exoskeleton design with the human-in-the-loop simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all the components. The final design is being manufactured and will be used within the tests with humans, reflecting almost fully automatic passive and active therapy.
- 12 January 2026
- Published by MDPI AG in Preprints.org
Open AccessOptimization-Based Design of a Lightweight Rehabilitation Exoskeleton of an Upper Extremity for Task-Oriented Treatment
Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients, neurological, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons - wearable devices mobilizing multiple joints with complex motions representing activities of daily living. To perform the kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology of decreasing the mass of the exoskeleton design with the human-in-the-loop simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all the components. The final design is being manufactured and will be used within the tests with humans, reflecting almost fully automatic passive and active therapy.
- 5 January 2024
- Published by Springer Nature
- p. 99-109
Optimal Control of Open–Loop Multibody Systems Recovered from Data
- 5 January 2024
- Published by Springer Nature
- p. 99-109
Optimal Control of Open–Loop Multibody Systems Recovered from Data