LQLongqing Qiu

Longqing Qiu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Longqing Qiu has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Liangliang Rong

    Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China

    4 shared publications
  • Guofeng Zhang

    Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China

    3 shared publications
  • Hui Dong

    Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China

    3 shared publications
  • Jun Wu

    Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China

    3 shared publications
  • Shu-Lin Zhang

    Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China

    2 shared publications
  • Xiaoming Xie

    Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Science, Shanghai, CHINA

    2 shared publications

Latest Publications

  • Open Access

    A Remote Two-Point Magnetic Localization Method Based on SQUID Magnetometers and Magnetic Gradient Tensor Invariants

    by Yingzi Zhang, Gaigai Liu, Chen Wang, Longqing Qiu, Hongliang Wang, Wenyi Liu

    In practical application, existing two-point magnetic gradient tensor (MGT) localization methods have a maximum detection distance of only 2.5 m, and the magnetic moment vectors of measured targets are all unknown. In order to realize remote, real-time localization, a new two-point magnetic localization method based on self-developed, ultra-sensitive superconducting quantum interference device (SQUID) magnetometers and MGT invariants is proposed. Both the magnetic moment vector and the relative position vector can be directly calculated based on the linear positioning model, and a quasi-Newton optimization algorithm is adopted to further improve the interference suppression capability. The simulation results show that the detection distance of the proposed method can reach 500 m when the superconducting MGT measurement system is used. Compared with Nara’s single-point tensor (NSPT) method and Xu’s two-point tensor (XTPT) method, the proposed method produces the smallest relative localization error (i.e., significantly less than 1% in the non-positioning blind area) without sacrificing real-time characteristics. The causes of and solutions to the positioning blind area are also analyzed. The equivalent experiments, which were conducted with a detection distance of 10 m, validate the effectiveness of the localization method, yielding a minimum relative localization error of 4.5229%.


  • A Planar Gradiometer With Discrete SQUID Current Sensor and Long-Baseline Pickup Coil

    by Zhi Ni, Guofeng Zhang, Jun Wu, Longqing Qiu, Xiaoyu Liu, Hui Dong, Liangliang Rong, Xiaoming Xie

    We have developed and fabricated a LTS SQUID gradiometer using Direct writing lithography technology. A niobium thin-film first-order pickup coil is connected to the input coil of a SQUID current sensor via superconducting niobium wire bonds. Both, the fine-scale Josephson junctions and the large-scale pickup coil, are fabricated by this technology. The SQUID is designed as a first-order gradiometer with a dual square washer configuration which was fabricated in a cross-type Josephson junction technology. The inner dimension of each pickup loop is 1.3 cm × 1.3 cm with a baseline of 6.2 cm, which results in a magnetic field gradient sensitivity of 0.3 nT/(cm·Φ 0 ). The white noise of the SQUID gradiometer is measured to be 2.6 µΦ 0 /Hz 1/2 corresponding to a magnetic field gradient noise of 99 fT/(m·Hz 1/2 ) in the white noise region. We also investigated the gradiometer performance in different environments. The performance specifications could be improved by integrating SQUID and first-order pickup coil on the same chip in the future.


  • Noise Compensation of a Mobile LTS SQUID Planar Gradiometer for Aeromagnetic Detection

    by Zhengwei Song, Yifeng Pei, Shulin Zhang, Xiaoming Xie, Haibin Dai, Liangliang Rong, Hui Dong, Jun Wu, Longqing Qiu, Guofeng Zhang, et al.

    A SQUID planar gradiometer is an extremely sensitive sensor for magnetic gradient measurements. It has been shown to have potential applications for aeromagnetic detection. The major challenge when operating an aeromagnetic SQUID system in actual environment is the motion noise, including the inherent response resulting from gradiometer imbalance and from magnetic interferences. Three orthogonal reference magnetometers are usually adopted to improve the gradiometer balance. However, magnetic interference coming from the system itself also needs to be compensated. In this paper, a mathematical model of the motion noise picked up by the gradiometer is derived from the traditional magnetic total field compensation method. Based on the model, the signals from the triaxial magnetometer can also be used to compensate the eddy current contribution to the magnetic interference. To verify the compensation method, a SQUID planar gradiometer system was set up and used for flight trials. The gradient field noise and imbalance of our homemade gradiometer were measured to be 100 fT/m/rt(Hz) and 2E-4 in the lab. In flight, the motion-induced peak-to-peak output of the gradiometer was reduced from 170 nT/m to about 0.1 nT/m, so that a magnetic anomaly signal of about 2 nT/m from a cargo ship was clearly recognized.


  • High-Performance Dual-Channel Squid-Based TEM System and Its Application

    by Liangliang Rong, Su Xin Bao, Jun Wu, Guofeng Zhang, Longqing Qiu, Shulin Zhang, Yongliang Wang, Hui Dong, Yi Feng Pei, Xiaoming Xie

    Transient Electromagnetic Method (TEM) is an effective way for mineral resource prospecting if an induction coil is used as the traditional sensor. Superconducting Quantum Inter-ference Device (SQUID) obtains excellent sensitivity at low fre-quency compared to coil. Thus the exploration depth and accura-cy of TEM can be greatly improved. However, ultra high slew rate (>10mT/s) is needed for transient primary field recording, which is a great challenge for a single high-sensitivity SQUID re-ceiver. In this paper, two SQUIDs with different sensitivities (1.5nT/ $\Phi_0$ & 99nT/ $\Phi_0$ ) are employed to record the whole TEM decaying signal. The high-sensitivity SQUID (1.5nT/ $\Phi_0$ ) is in reset status when transmitting and becomes locked after tens of μs af-ter transmitting has been cut off. The low-sensitivity SQUID (99 nT/ $\Phi_0$ ) remains locked during the whole procedure with high slew rate (~198mT/s) to record the fast-switching transmitting field. The two channel SQUID outputs are combined together to form a complete decaying curve. A field test was carried out. The decaying curve with noise level of 100fT@DC-25kHz and a fast-switching field of ~630nT cutting off in tens of μs (slew rate up to ~56mT/s) was recorded after stacking. This dual-channel SQUID based TEM system obtains high stability, which is useful for small transmitting loop (<50m) configuration.


  • Open Access

    Initial Results from SQUID Sensor: Analysis and Modeling for the ELF/VLF Atmospheric Noise

    by Huan Hao, Huali Wang, Liang Chen, Jun Wu, Longqing Qiu, Liangliang Rong

    In this paper, the amplitude probability density (APD) of the wideband extremely low frequency (ELF) and very low frequency (VLF) atmospheric noise is studied. The electromagnetic signals from the atmosphere, referred to herein as atmospheric noise, was recorded by a mobile low-temperature superconducting quantum interference device (SQUID) receiver under magnetically unshielded conditions. In order to eliminate the adverse effect brought by the geomagnetic activities and powerline, the measured field data was preprocessed to suppress the baseline wandering and harmonics by symmetric wavelet transform and least square methods firstly. Then statistical analysis was performed for the atmospheric noise on different time and frequency scales. Finally, the wideband ELF/VLF atmospheric noise was analyzed and modeled separately. Experimental results show that, Gaussian model is appropriate to depict preprocessed ELF atmospheric noise by a hole puncher operator. While for VLF atmospheric noise, symmetric α-stable (SαS) distribution is more accurate to fit the heavy-tail of the envelope probability density function (pdf).