JKJingyi Kang

Jingyi Kang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jingyi Kang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Accessing ultrastable glass via a bulk transformation

    by Hengtong Bu, Hengwei Luan, Jingyi Kang, Jili Jia, Wenhui Guo, Yunshuai Su, Huaping Ding, Hsiang-Shun Chang, Ranbin Wang, You Wu, et al.

    As a medium to understand the nature of glass transition, ultrastable glasses have garnered increasing attention for their significance in fundamental science and technological applications. Most studies have produced ultrastable glasses through a surface-controlled process using physical vapor deposition. Here, we demonstrate an approach to accessing ultrastable glasses via the glass-to-glass transition, a bulk transformation that is inherently free from size constraints and anisotropy. The resulting ultrastable glass exhibits a significantly enhanced density (improved by 2.3%), along with high thermodynamic, kinetic, and mechanical stability. Furthermore, we propose that this method of accessing ultrastable glasses is general for metallic glasses, based on the examination of the competitive relationship between the glass-to-glass transition and crystallization. This strategy is expected to facilitate the proliferation of the ultrastable glass family, helping to resolve the instability issues of glass materials and devices and deepen our understanding of glasses and the glass transition.


  • Spring-reinforced pneumatic actuator and soft robotic applications

    by Boyu Zhang, Xiangming Gu, Jiayuan Liu, Jingyi Kang, Chengquan Hu, Hongen Liao

    Compared to rigid-structure robots, soft robots possess higher degrees of freedom and stronger environmental adaptability, which has aroused increasing attention in the robotic field. Among them, soft pneumatic robots have excellent performances in various practical applications. However, the nonlinearity and instability of pressure response of soft actuators caused by lateral expansion come to a great challenge. To address this problem, we proposed to embed a spring constraint layer around each single air chamber. Following the design concept, we obtained single-cavity and multi-DoF pneumatic actuators and evaluated their elongation and bending characteristics. Experimental results demonstrated that our proposed actuators have more linear pressure response as well as higher consistency. Eventually, through robotic applications, including soft robotic hand and gripper our proposed actuators could facilitate flexible manipulation and elaborate performance.


  • A robot-assisted tracheal intubation system based on a soft actuator

    by Jiayuan Liu, Longfei Ma, Chengquan Hu, Jingyi Kang, Boyu Zhang, Ruiyang Li, Hongen Liao

    Purpose Tracheal intubation is the gold standard of airway protection and constitutes a pivotal life-saving technique frequently employed in emergency medical interventions. Hence, in this paper, a system is designed to execute tracheal intubation tasks automatically, offering a safer and more efficient solution, thereby alleviating the burden on physicians. Methods The system comprises a tracheal tube with a bendable front end, a drive system, and a tip endoscope. The soft actuator provides two degrees of freedom for precise orientation. It is fabricated with varying-hardness silicone and reinforced with fibers and spiral steel wire for flexibility and safety. The hydraulic actuation system and tube feeding mechanism enable controlled bending and delivery. Object detection of key anatomical features guides the robotic arm and soft actuator. The control strategy involves visual servo control for coordinated robotic arm and soft actuator movements, ensuring accurate and safe tracheal intubation. Results The kinematics of the soft actuator were established using a constant curvature model, allowing simulation of its workspace. Through experiments, the actuator is capable of 90° bending as well as 20° deflection on the left and right sides. The maximum insertion force of the tube is 2 N. Autonomous tracheal intubation experiments on a training manikin were successful in all 10 trials, with an average insertion time of 45.6 s. Conclusion Experimental validation on the manikin demonstrated that the robot tracheal intubation system based on a soft actuator was able to perform safe, stable, and automated tracheal intubation. In summary, this paper proposed a safe and automated robot-assisted tracheal intubation system based on a soft actuator, showing considerable potential for clinical applications.


  • Peristaltic Pump-Based Palm-Sized Multi-Mode Pressure Supply System for Soft Robots

    by Chengquan Hu, Jingyi Kang, Jiayuan Liu, Jie Wang, Hongen Liao

    Soft robots have garnered considerable interest in recent years in terms of structure and functionality, while commercially viable pressure supply systems with various pressure supply modes for soft robots remain slow to progress. Hence, in this work, a palm-sized multi-mode pressure supply system based on a peristaltic pump is proposed for the first time, and precise pneumatic pressure control is achieved with a model reference adaptive control (MRAC) method based on the system dynamics. Further performance evaluation demonstrates that our system can deliver precise positive (mean error < 0.48 kPa for 0 $\sim$ 50 kPa) and negative pressures (mean error < 0.85 kPa for −50 $\sim$ 0 kPa) with minimal fluctuations, which outperforms the PID method. Application experiments indicate that our system can accommodate various pressure supply requirements, including controllable pressurization and depressurization, and has the potential for both pneumatic and hydraulic applications. In addition, by incorporating the MRAC method into the system, we have achieved excellent stability and high repeatability in controlling the position of a retractable soft pneumatic actuator, thus demonstrating the system's high accuracy and repeatability in pressure output. The phantom experiment of the injection soft robotic system further validates the system's diverse pressure supply capabilities for complex manipulations of soft robots.