Tansu Özel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tansu Özel has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Carsten Cremers
Fraunhofer Institute for Chemical Technology (ICT)
3 shared publications - Stefan Bürger
Fraunhofer Institute for Chemical Technology (ICT)
2 shared publications Samuel Kraft
Fraunhofer Institute for Chemical Technology (ICT)
1 shared publication
Latest Publications
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (46) , 3272
Investigation of the Effect of Ammonia As Ambient Air Contaminant on PEM Fuel Cell Stack Performance and Degradation Using EIS, Thda and Different Gas Analysis Methods
The negative effects of airborne contaminants on polymer electrolyte membrane fuel cell (PEMFC) have already been shown in several publications. [1] Among these contaminants, ammonia (NH3) with its multistep reversible and irreversible effects is particularly significant. Recent studies on air quality in urban areas have revealed a notable increase in ammonia levels within a span of two years. [2] This rapid increase can be attributed to the growing prevalence of EURO-6 diesel vehicles equipped with selective catalytic reduction (SCR) cats, which results in ammonia slip during the nitrogen oxide reduction process in diesel engines. [2] Ambient air is the most common used oxidant gas in mobile and stationary PEM fuel cell systems. The performance of fuel cell can suffer beyond the oxygen gain from airborne contaminants, which also have the potential to accelerate degradation. To prevent that airborne contaminants reach the fuel cell cathode, air filter systems consisting of particle filter and specially for fuel cell requirements developed filter are installed at the cathode inlet. Despite the installation of an air filter system, airborne contaminants can still reach the fuel cell cathode. The focus of this investigation is on the effects of ammonia in PEM fuel cell stacks. In contrast to single cell operation, stack operation can introduce additional effects such as cell-to-cell inhomogeneities and varying degrees of ammonia-induced degradation among cells. For the investigation, experiments with a PEMFC stack are going to be done on a fuel cell testbed equipped with an impedance analyzer. Ammonia is going to be mixed into the cathode air in the ppb range. Its effects on PEMFC stack performance are going to be investigated with electrochemical impedance spectroscopy (EIS) and total harmonic distortion analysis (THDA). The cathode exhaust gas is also going to be analyzed by gas analyzers such as FTIR gas analyzer and mass spectrometry. It is planned to test the PEMFC stack under different operating conditions like temperature, relative humidity and pressure of inlet gases, with various parameters and different cathode gas mix ratios while monitoring possible conversion of impurities via FTIR and the stack state of health using THDA and conventional technologies to understand the link between the effect of ammonia on fuel cell stack performance, on its lifetime and to determine possible early indicators. References [1] Misz, U., Talke, A., Heinzel, A., and Konrad, G. 2016. Sensitivity Analyses on the Impact of Air Contaminants on Automotive Fuel Cells. Fuel Cells 16, 4, 444–462. [2] R. Wegener, U. Javed, R. Dubus, and D. Klemp. 2024. Investigations of Air Quality Aspects with the Urban Climate Model PALM4U.
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (46) , 3272
Investigation of the Effect of Ammonia As Ambient Air Contaminant on PEM Fuel Cell Stack Performance and Degradation Using EIS, Thda and Different Gas Analysis Methods
The negative effects of airborne contaminants on polymer electrolyte membrane fuel cell (PEMFC) have already been shown in several publications. [1] Among these contaminants, ammonia (NH3) with its multistep reversible and irreversible effects is particularly significant. Recent studies on air quality in urban areas have revealed a notable increase in ammonia levels within a span of two years. [2] This rapid increase can be attributed to the growing prevalence of EURO-6 diesel vehicles equipped with selective catalytic reduction (SCR) cats, which results in ammonia slip during the nitrogen oxide reduction process in diesel engines. [2] Ambient air is the most common used oxidant gas in mobile and stationary PEM fuel cell systems. The performance of fuel cell can suffer beyond the oxygen gain from airborne contaminants, which also have the potential to accelerate degradation. To prevent that airborne contaminants reach the fuel cell cathode, air filter systems consisting of particle filter and specially for fuel cell requirements developed filter are installed at the cathode inlet. Despite the installation of an air filter system, airborne contaminants can still reach the fuel cell cathode. The focus of this investigation is on the effects of ammonia in PEM fuel cell stacks. In contrast to single cell operation, stack operation can introduce additional effects such as cell-to-cell inhomogeneities and varying degrees of ammonia-induced degradation among cells. For the investigation, experiments with a PEMFC stack are going to be done on a fuel cell testbed equipped with an impedance analyzer. Ammonia is going to be mixed into the cathode air in the ppb range. Its effects on PEMFC stack performance are going to be investigated with electrochemical impedance spectroscopy (EIS) and total harmonic distortion analysis (THDA). The cathode exhaust gas is also going to be analyzed by gas analyzers such as FTIR gas analyzer and mass spectrometry. It is planned to test the PEMFC stack under different operating conditions like temperature, relative humidity and pressure of inlet gases, with various parameters and different cathode gas mix ratios while monitoring possible conversion of impurities via FTIR and the stack state of health using THDA and conventional technologies to understand the link between the effect of ammonia on fuel cell stack performance, on its lifetime and to determine possible early indicators. References [1] Misz, U., Talke, A., Heinzel, A., and Konrad, G. 2016. Sensitivity Analyses on the Impact of Air Contaminants on Automotive Fuel Cells. Fuel Cells 16, 4, 444–462. [2] R. Wegener, U. Javed, R. Dubus, and D. Klemp. 2024. Investigations of Air Quality Aspects with the Urban Climate Model PALM4U.
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (38) , 1863
Investigation of the Effect of Graphite Bipolar Plate Flow Channel Inhomogeneities and Faults on HT-PEM Fuel Cell Stack Performance
Bipolar plates are a key component of fuel cell stacks. Bipolar plates have multiple functions. They connect the single cells of the stack electrically and must be therefore electrically conductive. They separate oxidant and fuel gases and distribute them on each side over the membrane-electrode-assembly (MEA). Bipolar plates separate coolant liquid too. Fuel cell stack is cooled by coolant liquid which is flowing through the cooling flow channels in the middle of bipolar plates. Especially the bipolar plates for HT-PEM must endure a low pH environment, continuous electrical potential, and higher temperatures up to 200°C. The focus here is on investigations of anode and cathode side flow channels of graphite bipolar plates. Inhomogeneities and faults of flow channels are examined and their effects on fuel cell stack performance are analyzed. The analyses are based on optical scan data of flow channel geometry and measurement data of a HT-PEM fuel cell full stack consisting of 120 cells operated on a testbed under different variations. Inlet pressure and stoichiometry of both anode and cathode were varied, anode was fed with pure hydrogen and with different reformate gas compositions consisting of hydrogen, nitrogen, carbon dioxide and carbon monoxide. For each variation point, polarization curves between 0 A/cm2 – 0,55 A/cm2 in step of 0,05 A/cm2 were recorded. With an on testbed installed cell voltage monitoring (CVM) system voltages of every cell were measured and logged. Enormous amount of optical scan data consisting of width and depth information of flow channels was merged to certain statistical data for anode and cathode bipolar plates. Correlations between statistical data and cell voltages are still being investigated. It is planned to repeat the measurements with another 120 cells HT-PEM fuel cell full stack and compare the results.
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (38) , 1863
Investigation of the Effect of Graphite Bipolar Plate Flow Channel Inhomogeneities and Faults on HT-PEM Fuel Cell Stack Performance
Bipolar plates are a key component of fuel cell stacks. Bipolar plates have multiple functions. They connect the single cells of the stack electrically and must be therefore electrically conductive. They separate oxidant and fuel gases and distribute them on each side over the membrane-electrode-assembly (MEA). Bipolar plates separate coolant liquid too. Fuel cell stack is cooled by coolant liquid which is flowing through the cooling flow channels in the middle of bipolar plates. Especially the bipolar plates for HT-PEM must endure a low pH environment, continuous electrical potential, and higher temperatures up to 200°C. The focus here is on investigations of anode and cathode side flow channels of graphite bipolar plates. Inhomogeneities and faults of flow channels are examined and their effects on fuel cell stack performance are analyzed. The analyses are based on optical scan data of flow channel geometry and measurement data of a HT-PEM fuel cell full stack consisting of 120 cells operated on a testbed under different variations. Inlet pressure and stoichiometry of both anode and cathode were varied, anode was fed with pure hydrogen and with different reformate gas compositions consisting of hydrogen, nitrogen, carbon dioxide and carbon monoxide. For each variation point, polarization curves between 0 A/cm2 – 0,55 A/cm2 in step of 0,05 A/cm2 were recorded. With an on testbed installed cell voltage monitoring (CVM) system voltages of every cell were measured and logged. Enormous amount of optical scan data consisting of width and depth information of flow channels was merged to certain statistical data for anode and cathode bipolar plates. Correlations between statistical data and cell voltages are still being investigated. It is planned to repeat the measurements with another 120 cells HT-PEM fuel cell full stack and compare the results.
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (37) , 1796
Investigation of the Effect of Airborne Contaminants on PEM Fuel Cell Stack Performance and Degradation Using Electrochemical Impedance Spectroscopy, AVL Thda™ and FTIR Gas Analyzer
Air pollution is still a bitter truth in many locations in the world. In highly populated regions like metropolitan areas as well as in agricultural areas there are various airborne contaminants which can be harmful to organisms. Also fuel cells, especially PEMFC are sensitive to airborne contaminants. In most mobile and stationary PEM fuel cell systems, ambient air is used as oxidant gas at the cathode of the fuel cell. It is cost and weight saving because there is no need to install additional tank for pure oxygen and to refill it, but the performance of fuel cell can suffer beyond the oxygen gain from airborne contaminants, which also have the potential to accelerate degradation. To prevent that airborne contaminants reach the fuel cell cathode, air filter systems consisting of particle filter and additional activated carbon filter are installed at the cathode inlet. The focus here is on the investigation of the use of AVL THDAtm method to detect effects of airborne contaminants. THDA (total harmonic distortion analysis) is a patented online fuel cell monitoring method based on analyzing harmonic distortion effects of voltage drifts instead of single cell voltage measurement. So far it was successfully demonstrated for the detection of water issues like flooding and drying, and for low media supply issues on both cathode and anode side [1, 2]. For the development and validation of the method, experiments with a PEMFC stack are going to be done on a fuel cell testbed equipped with an AVL X-Ion impedance analyzer. Specific air pollutant gases ammonia (NH3), sulfur dioxide (SO2) and nitrogen oxides (NOx) are going to be mixed into the cathode air in the ppb range. Their effects on PEMFC stack performance are going to be investigated with electrochemical impedance spectroscopy (EIS) and total harmonic distortion analysis. The cathode exhaust gas is also going to be analyzed by an FTIR gas analyzer. It is planned to test the PEMFC stack under different operating conditions, with various parameters and different cathode gas mix ratios while monitoring possible conversion of impurities via FTIR and the stack state of health using THDA and conventional technologies to understand the link between the effect of airborne contaminants on fuel cell stack performance, on its lifetime and to determine possible early indicators in the THDA signals. References [1] Mitzel, J., Sanchez‐Monreal, J., Garcia‐Sanchez, D., Gazdzicki, P., Schulze, M., Häußler, F., Hunger, J., Schlumberger, G., Janicka, E., Mielniczek, M., and Gawel, L. 2020. Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis. Fuel Cells 20, 4, 403–412. [2] Ramschak, E., Peinecke, V., Prenninger, P., Schaffer, T., and Hacker, V. 2006. Detection of fuel cell critical status by stack voltage analysis. Journal of Power Sources 157, 2, 837–840.
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (37) , 1796
Investigation of the Effect of Airborne Contaminants on PEM Fuel Cell Stack Performance and Degradation Using Electrochemical Impedance Spectroscopy, AVL Thda™ and FTIR Gas Analyzer
Air pollution is still a bitter truth in many locations in the world. In highly populated regions like metropolitan areas as well as in agricultural areas there are various airborne contaminants which can be harmful to organisms. Also fuel cells, especially PEMFC are sensitive to airborne contaminants. In most mobile and stationary PEM fuel cell systems, ambient air is used as oxidant gas at the cathode of the fuel cell. It is cost and weight saving because there is no need to install additional tank for pure oxygen and to refill it, but the performance of fuel cell can suffer beyond the oxygen gain from airborne contaminants, which also have the potential to accelerate degradation. To prevent that airborne contaminants reach the fuel cell cathode, air filter systems consisting of particle filter and additional activated carbon filter are installed at the cathode inlet. The focus here is on the investigation of the use of AVL THDAtm method to detect effects of airborne contaminants. THDA (total harmonic distortion analysis) is a patented online fuel cell monitoring method based on analyzing harmonic distortion effects of voltage drifts instead of single cell voltage measurement. So far it was successfully demonstrated for the detection of water issues like flooding and drying, and for low media supply issues on both cathode and anode side [1, 2]. For the development and validation of the method, experiments with a PEMFC stack are going to be done on a fuel cell testbed equipped with an AVL X-Ion impedance analyzer. Specific air pollutant gases ammonia (NH3), sulfur dioxide (SO2) and nitrogen oxides (NOx) are going to be mixed into the cathode air in the ppb range. Their effects on PEMFC stack performance are going to be investigated with electrochemical impedance spectroscopy (EIS) and total harmonic distortion analysis. The cathode exhaust gas is also going to be analyzed by an FTIR gas analyzer. It is planned to test the PEMFC stack under different operating conditions, with various parameters and different cathode gas mix ratios while monitoring possible conversion of impurities via FTIR and the stack state of health using THDA and conventional technologies to understand the link between the effect of airborne contaminants on fuel cell stack performance, on its lifetime and to determine possible early indicators in the THDA signals. References [1] Mitzel, J., Sanchez‐Monreal, J., Garcia‐Sanchez, D., Gazdzicki, P., Schulze, M., Häußler, F., Hunger, J., Schlumberger, G., Janicka, E., Mielniczek, M., and Gawel, L. 2020. Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis. Fuel Cells 20, 4, 403–412. [2] Ramschak, E., Peinecke, V., Prenninger, P., Schaffer, T., and Hacker, V. 2006. Detection of fuel cell critical status by stack voltage analysis. Journal of Power Sources 157, 2, 837–840.