SBStefan Bürger

Stefan Bürger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stefan Bürger has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Investigation of the Effect of Ammonia As Ambient Air Contaminant on PEM Fuel Cell Stack Performance and Degradation Using EIS, Thda and Different Gas Analysis Methods

    by Tansu Özel, Stefan Bürger, Carsten Cremers

    The negative effects of airborne contaminants on polymer electrolyte membrane fuel cell (PEMFC) have already been shown in several publications. [1] Among these contaminants, ammonia (NH3) with its multistep reversible and irreversible effects is particularly significant. Recent studies on air quality in urban areas have revealed a notable increase in ammonia levels within a span of two years. [2] This rapid increase can be attributed to the growing prevalence of EURO-6 diesel vehicles equipped with selective catalytic reduction (SCR) cats, which results in ammonia slip during the nitrogen oxide reduction process in diesel engines. [2] Ambient air is the most common used oxidant gas in mobile and stationary PEM fuel cell systems. The performance of fuel cell can suffer beyond the oxygen gain from airborne contaminants, which also have the potential to accelerate degradation. To prevent that airborne contaminants reach the fuel cell cathode, air filter systems consisting of particle filter and specially for fuel cell requirements developed filter are installed at the cathode inlet. Despite the installation of an air filter system, airborne contaminants can still reach the fuel cell cathode. The focus of this investigation is on the effects of ammonia in PEM fuel cell stacks. In contrast to single cell operation, stack operation can introduce additional effects such as cell-to-cell inhomogeneities and varying degrees of ammonia-induced degradation among cells. For the investigation, experiments with a PEMFC stack are going to be done on a fuel cell testbed equipped with an impedance analyzer. Ammonia is going to be mixed into the cathode air in the ppb range. Its effects on PEMFC stack performance are going to be investigated with electrochemical impedance spectroscopy (EIS) and total harmonic distortion analysis (THDA). The cathode exhaust gas is also going to be analyzed by gas analyzers such as FTIR gas analyzer and mass spectrometry. It is planned to test the PEMFC stack under different operating conditions like temperature, relative humidity and pressure of inlet gases, with various parameters and different cathode gas mix ratios while monitoring possible conversion of impurities via FTIR and the stack state of health using THDA and conventional technologies to understand the link between the effect of ammonia on fuel cell stack performance, on its lifetime and to determine possible early indicators. References [1] Misz, U., Talke, A., Heinzel, A., and Konrad, G. 2016. Sensitivity Analyses on the Impact of Air Contaminants on Automotive Fuel Cells. Fuel Cells 16, 4, 444–462. [2] R. Wegener, U. Javed, R. Dubus, and D. Klemp. 2024. Investigations of Air Quality Aspects with the Urban Climate Model PALM4U.

  • Characterizing Reversible and Irreversible Degradation Effects of PEM Water Electrolyzer Stacks

    by Felix Dittmar, Stefan Bürger, Carsten Cremers

    Polymer electrolyte membrane water electrolyzers (PEMEL) have been identified as a key component in a decarbonized large-scale energy system, as they can produce high-purity hydrogen from renewable electricity sources for the chemical industry or energy storage. However, the long-term durability and performance of PEM electrolyzers remain a major challenge, with degradation being a critical factor that limits their lifespan and efficiency. Recent studies have focused on developing accelerated stress test (AST) protocols for PEM electrolyzers to better understand the conditions and mechanisms that lead to degradation.1, 2 Especially the reversible rise in cell potential, which in the literature is often regarded as apparent or reversible degradation, must be further investigated to find mitigation strategies for operation.3, 4 We present our research on the development of two testing protocols (static, dynamic) characterizing reversible and irreversible degradation effects for PEMEL stacks in different operation modes. Our aim is to gain a better understanding of the variance of these phenomena in general and the recovery of reversible effects across PEMEL stacks. The measurements are carried out on a commercialized Greenlight E400 test bench equipped with a 7kW 8 cell PEMEL stack (Hydrogen Innovation GmbH). The potential of all cells will be monitored during testing. The measurements include repeated electrochemical characterization protocols measuring i/E-curves, HFR and impedance spectroscopy (EIS) of the PEMEL stack and if possible, every single cell. These protocols include the introduction of low potential regeneration phases before every characterization during the test protocol to distinguish between reversible effects and the irreversible cell degradation. This was seen to be effective for potential recovery by Suermann et al. 2019 for single PEMEL cells.4 The results consist of a description of the two testing procedures and the used equipment. Due to the duration of each test protocol (3000 h) only results of the static test protocol can be presented. The contribution of the presented research is threefold. Firstly, we break down the degradation across a whole stack. Giving valuable insights regarding the distribution of cell efficiency and degradation effects. Secondly, the presented test protocols characterize and account for the reversible rise in cell/stack potential. Thirdly, the characterization of the recovery time of the cell potential across the stack will have implications for the operation of stacks to mitigate or recover these performance losses. We address both static and dynamic operation modes aiming to simulate the application of PEMEL stacks for a constant production of hydrogen used in downstream processes and the volatile operation due to a direct coupling with renewable energy sources. This publication is to be seen as presentation of first results in our ongoing research to find test protocols for short stack systems to develop operation strategies, which can be applied to large scale electrolyzer systems. Furthermore, we try to deepen the understanding of the reversible cell potential rise as well as standardize the general testing of PEMEL stacks. This work is funded by the Federal Ministry of Education and Research (BMBF) in the project “hyBit” under the grant 03SF0687E. The authors declare that the opinions expressed in this submission are their own and are based on a thorough review of existing scientific literature. Sources 1. G. Tsotridis and A. Pilenga, EU harmonized protocols for testing of low temperature water electrolysis, Publications Office of the European Union, Luxembourg (2021). 2. A. Voronova, H.-J. Kim, J. H. Jang, H.-Y. Park and B. Seo, International Journal of Energy Research, 46 (2022) 11867. 3. C. Rakousky, U. Reimer, K. Wippermann, S. Kuhri, M. Carmo, W. Lueke and D. Stolten, Journal of Power Sources, 342 (2017) 38. 4. M. Suermann, B. Bensmann and R. Hanke-Rauschenbach, Journal of The Electrochemical Society, 166 (2019) F645-F652.


  • Design and Construction of a LT-PEM Fuel Cell System for Aviation Application

    by Stefan Bürger, Carsten Cremers, Niels Urban

    Fuel cell technology has gained considerable attention as an alternative power source for mobility applications. Fuel cell systems are already integrated in ground applications like trucks, cars, and busses. One reason is, that they have the potential to provide an environmentally friendly power supply solution compared to traditional combustion engines. Moreover, fuel cell drive trains offer several potential benefits, such as improved energy efficiency, noise reduction and no local emissions and even zero CO2 emission if they are fueled with green hydrogen. On the other hand, there are several key challenges associated with the integration of fuel cell technology into mobility applications, such as safety, durability, weight, and cost. These challenges become even more difficult when flight applications are considered, due to the higher . We present our research of a fuel cell system design, which is constructed to power a one seat airplane, the Antares E2. This system will utilize compressed Hydrogen as fuel to power up to six electronic motors via an electric bus. The airplane needs 90 kW of power mainly for its electric propulsion and can be operated up to a ceiling altitude of 6500 m (21,300 ft). For redundancy and safety, it is necessary to split the power output to at least two systems. Therefore, each system must have a power output of 45 kW. The fuel cell system's design takes various factors into account, such as lightweight and compact components as well as safety analysis to ensure the operation in flight. To reach aviation standards a full FMEA analysis is conducted, to calculate the risks of operating the systems on an airplane. The goal is to have a fuel cell system which is eligible for operating an aircraft. We want to present first results of our research, consisting of first design to ground operation and include some simulations for flight conditions. A successful development and certification of this fuel cell system would represent a significant milestone in the pursuit of sustainable aviation technologies, since it would be one of the first system which features approved airworthiness. This technology has the potential to reduce emissions and noise pollution associated with traditional combustion engines. Further research and development efforts are required to optimize the performance and reduce the cost of this fuel cell system. This work is funded by the Federal Ministry for Digital and Transport (BMDV) in the project “H2GA” under the grant 03B10707. The authors declare that the opinions expressed in this submission are their own and are based on a thorough review of existing scientific literature.

  • Investigation of the Effect of Airborne Contaminants on PEM Fuel Cell Stack Performance and Degradation Using Electrochemical Impedance Spectroscopy, AVL Thda™ and FTIR Gas Analyzer

    by Tansu Özel, Stefan Bürger, Carsten Cremers

    Air pollution is still a bitter truth in many locations in the world. In highly populated regions like metropolitan areas as well as in agricultural areas there are various airborne contaminants which can be harmful to organisms. Also fuel cells, especially PEMFC are sensitive to airborne contaminants. In most mobile and stationary PEM fuel cell systems, ambient air is used as oxidant gas at the cathode of the fuel cell. It is cost and weight saving because there is no need to install additional tank for pure oxygen and to refill it, but the performance of fuel cell can suffer beyond the oxygen gain from airborne contaminants, which also have the potential to accelerate degradation. To prevent that airborne contaminants reach the fuel cell cathode, air filter systems consisting of particle filter and additional activated carbon filter are installed at the cathode inlet. The focus here is on the investigation of the use of AVL THDAtm method to detect effects of airborne contaminants. THDA (total harmonic distortion analysis) is a patented online fuel cell monitoring method based on analyzing harmonic distortion effects of voltage drifts instead of single cell voltage measurement. So far it was successfully demonstrated for the detection of water issues like flooding and drying, and for low media supply issues on both cathode and anode side [1, 2]. For the development and validation of the method, experiments with a PEMFC stack are going to be done on a fuel cell testbed equipped with an AVL X-Ion impedance analyzer. Specific air pollutant gases ammonia (NH3), sulfur dioxide (SO2) and nitrogen oxides (NOx) are going to be mixed into the cathode air in the ppb range. Their effects on PEMFC stack performance are going to be investigated with electrochemical impedance spectroscopy (EIS) and total harmonic distortion analysis. The cathode exhaust gas is also going to be analyzed by an FTIR gas analyzer. It is planned to test the PEMFC stack under different operating conditions, with various parameters and different cathode gas mix ratios while monitoring possible conversion of impurities via FTIR and the stack state of health using THDA and conventional technologies to understand the link between the effect of airborne contaminants on fuel cell stack performance, on its lifetime and to determine possible early indicators in the THDA signals. References [1] Mitzel, J., Sanchez‐Monreal, J., Garcia‐Sanchez, D., Gazdzicki, P., Schulze, M., Häußler, F., Hunger, J., Schlumberger, G., Janicka, E., Mielniczek, M., and Gawel, L. 2020. Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis. Fuel Cells 20, 4, 403–412. [2] Ramschak, E., Peinecke, V., Prenninger, P., Schaffer, T., and Hacker, V. 2006. Detection of fuel cell critical status by stack voltage analysis. Journal of Power Sources 157, 2, 837–840.

  • Open Access

    Beam impact tests of a prototype target for the beam dump facility at CERN: Experimental setup and preliminary analysis of the online results

    by E. Lopez Sola, M. Calviani, O. Aberle, C. Ahdida, P. Avigni, M. Battistin, L. Bianchi, S. Burger, J. Busom Descarrega, J. Canhoto Espadanal, et al.

    The beam dump facility (BDF) is a project for a new facility at CERN dedicated to high intensity beam dump and fixed target experiments. Currently in its design phase, the first aim of the facility is to search for light dark matter and hidden sector models with the Search for Hidden Particles (SHiP) experiment. At the core of the facility sits a dense target/dump, whose function is to absorb safely the 400  GeV/c Super Proton Synchrotron (SPS) beam and to maximize the production of charm and beauty mesons. An average power of 300 kW will be deposited on the target, which will be subjected to unprecedented conditions in terms of temperature, structural loads and irradiation. In order to provide a representative validation of the target design, a prototype target has been designed, manufactured, and tested under the SPS fixed-target proton beam during 2018, up to an average beam power of 50 kW, corresponding to 350 kJ per pulse. The present contribution details the target prototype design and experimental setup, as well as a first evaluation of the measurements performed during beam irradiation. The analysis of the collected data suggests that a representative reproduction of the operational conditions of the beam dump facility target was achieved during the prototype tests, which will be complemented by a postirradiation examination campaign during 2020.