Jia Yi Fong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jia Yi Fong has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jerald Yoo
Department of Electrical and Computer Engineering, Seoul National University, Seoul, South Korea
3 shared publications Jiamin Li
School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, China
2 shared publications- Longyang Lin
Southern University of Science and Technology
2 shared publications - Astrid Rusly
Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117583, Singapore
1 shared publication - Benjamin Ho Yin Lee
Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117583, Singapore
1 shared publication - Donghan Kim
Department of Electrical and Computer Engineering, Seoul National University, Seoul 08826, Korea
1 shared publication
Latest Publications
- Open Access
- 1 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (18) , eaec9803
SkinECG: An orthogonal remote powering wearable skin-like sensor
The Internet of Things (IoT) era witnessed a surge in wearable devices for the human body, each requiring a power source that supports long-term operation. However, batteries are depletable and require replacement, while the effectiveness of energy-harvesting techniques is location specific. We developed the SkinECG system, an orthogonal remote powering skin-like electrocardiogram (ECG) sensor. It is powered by body-coupled powering (BCP) using power acquired optimally via suitable energy harvesters at different locations on the human body, solving the location mismatch between the energy-harvesting source and sensor. The remote Orthogonal Energy Harvesting Network (O-EHN) effectively transfers power from multiple energy-harvesting sources without internode interference and cancellation. We demonstrated the 0.71-mm-thin, flexible SkinECG system that conforms to the human chest and detects ECG signals without any cumbersome batteries or directly connected power for long-term health monitoring.
- 1 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (18) , eaec9803
Open AccessSkinECG: An orthogonal remote powering wearable skin-like sensor
The Internet of Things (IoT) era witnessed a surge in wearable devices for the human body, each requiring a power source that supports long-term operation. However, batteries are depletable and require replacement, while the effectiveness of energy-harvesting techniques is location specific. We developed the SkinECG system, an orthogonal remote powering skin-like electrocardiogram (ECG) sensor. It is powered by body-coupled powering (BCP) using power acquired optimally via suitable energy harvesters at different locations on the human body, solving the location mismatch between the energy-harvesting source and sensor. The remote Orthogonal Energy Harvesting Network (O-EHN) effectively transfers power from multiple energy-harvesting sources without internode interference and cancellation. We demonstrated the 0.71-mm-thin, flexible SkinECG system that conforms to the human chest and detects ECG signals without any cumbersome batteries or directly connected power for long-term health monitoring.
- Open Access
- 13 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59 (4) , 1006-1016
Concurrent Body-Coupled Powering and Communication ICs With a Single Electrode
Body-coupled powering (BCP) and body-coupled communication (BCC) utilize the human body channel as the wireless transmission medium, which shows less path loss around the body area. However, integrating both BCP and BCC requires multiple electrodes or alternating the uplink and downlink in the time domain, due to signal interferences and backflow between different paths. To address this issue, we propose a base station (BS) IC and a sensor node (SN) IC with BCP and BCC concurrency. At the BS, the adaptive self-interference cancellation (SI-C) structure suppresses the output signals that are coupled at the data receiver, enabling the concurrent uplink data recovery and downlink power delivery. At the SN, the ground domain of the uplink data path is separated from that of the downlink power/data path to suppress leakage between the paths. For regulated power supply in different ground domains, the cross-ground-domain power converter is designed with 89.1% efficiency. The ICs are implemented in a 40-nm 1P8M standard CMOS process, and BCC $+$ BCP concurrent operations are successfully validated.
- 13 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59 (4) , 1006-1016
Open AccessConcurrent Body-Coupled Powering and Communication ICs With a Single Electrode
Body-coupled powering (BCP) and body-coupled communication (BCC) utilize the human body channel as the wireless transmission medium, which shows less path loss around the body area. However, integrating both BCP and BCC requires multiple electrodes or alternating the uplink and downlink in the time domain, due to signal interferences and backflow between different paths. To address this issue, we propose a base station (BS) IC and a sensor node (SN) IC with BCP and BCC concurrency. At the BS, the adaptive self-interference cancellation (SI-C) structure suppresses the output signals that are coupled at the data receiver, enabling the concurrent uplink data recovery and downlink power delivery. At the SN, the ground domain of the uplink data path is separated from that of the downlink power/data path to suppress leakage between the paths. For regulated power supply in different ground domains, the cross-ground-domain power converter is designed with 89.1% efficiency. The ICs are implemented in a 40-nm 1P8M standard CMOS process, and BCC $+$ BCP concurrent operations are successfully validated.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Biomedical System-on-Chip Design with Integrated Body-Coupled Powering
Capacitive Body-Coupled Powering (BCP) has been demonstrated as an effective power delivery solution for wearable biomedical system-on-chips (SoC), thanks to its improved path loss compared to the RF-based transmission in the body area, and its insusceptibility to the body shadowing effect. Integrating BCP with biomedical SoCs could unlock potentials for a power-sustainable and long-lasting system design. In this paper, starting from the motivation for BCP, we will identify the challenges in the integration of BCP with other building blocks of the SoC (e.g., sensing front-end, transceiver). After reviewing and analyzing the existing techniques for BCP and a BCP-compatible SoC design, the design considerations and optimizations will be discussed.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Biomedical System-on-Chip Design with Integrated Body-Coupled Powering
Capacitive Body-Coupled Powering (BCP) has been demonstrated as an effective power delivery solution for wearable biomedical system-on-chips (SoC), thanks to its improved path loss compared to the RF-based transmission in the body area, and its insusceptibility to the body shadowing effect. Integrating BCP with biomedical SoCs could unlock potentials for a power-sustainable and long-lasting system design. In this paper, starting from the motivation for BCP, we will identify the challenges in the integration of BCP with other building blocks of the SoC (e.g., sensing front-end, transceiver). After reviewing and analyzing the existing techniques for BCP and a BCP-compatible SoC design, the design considerations and optimizations will be discussed.