Arik Subhana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Arik Subhana has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Frank Mauseth
Department of Electric Energy, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
3 shared publications - Marte Gammelsæter
SINTEF Energy Research, Trondheim, Norway
3 shared publications - Nina Sasaki Støa-Aanensen
SINTEF Energy Research, Trondheim, Norway
3 shared publications - Cedric Lesaint
SINTEF Energy Research, Trondheim, Norway
2 shared publications - A. H. M. Kamal
Department of Computer Science and Engineering, Jatiya Kabi Kazi Nazrul Islam University, Mymensingh, Bangladesh
1 shared publication Celia Shahnaz
Bangladesh University of Engineering and Technology,Department of Electrical and Electronic Engineering,Dhaka,1205
1 shared publication
Latest Publications
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (1) , 342-351
Aging of Environmentally Friendly Insulation Gases by Free-Burning Arcs: 7.5% C5-Fluoroketone With Technical Air
This paper explores how ageing by free-burning arcs affects the dielectric properties and decomposition of a mixture of 7.5% C5-fluoroketone (C5-FK) with 92.5% technical air (79% N2, 21% O2) at a pressure of 1.3 bar absolute. The gas is aged by exposure to consecutive arcs with a cumulative energy ∼315 kJ, a level relevant to medium voltage load break switches (LBS). To assess the long-term insulation performance, lightning impulse (LI) and AC breakdown tests are performed in a rod-plane electrode configuration before and after the ageing process. Additionally, gas decomposition is examined using gas chromatography and mass spectrometry. The results suggest that the LI breakdown voltage of the C5-FK/air mixture may decrease after ageing, likely due to C5-FK decomposition. Calculation of electron transport coefficients shows reduced attachment with C5-FK dissociation, which may decrease the discharge time delay. However, the discharge delay effects might not be observed in case of a slowly changing field, explaining why the AC breakdown voltage appears to be unaffected by ageing.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (1) , 342-351
Aging of Environmentally Friendly Insulation Gases by Free-Burning Arcs: 7.5% C5-Fluoroketone With Technical Air
This paper explores how ageing by free-burning arcs affects the dielectric properties and decomposition of a mixture of 7.5% C5-fluoroketone (C5-FK) with 92.5% technical air (79% N2, 21% O2) at a pressure of 1.3 bar absolute. The gas is aged by exposure to consecutive arcs with a cumulative energy ∼315 kJ, a level relevant to medium voltage load break switches (LBS). To assess the long-term insulation performance, lightning impulse (LI) and AC breakdown tests are performed in a rod-plane electrode configuration before and after the ageing process. Additionally, gas decomposition is examined using gas chromatography and mass spectrometry. The results suggest that the LI breakdown voltage of the C5-FK/air mixture may decrease after ageing, likely due to C5-FK decomposition. Calculation of electron transport coefficients shows reduced attachment with C5-FK dissociation, which may decrease the discharge time delay. However, the discharge delay effects might not be observed in case of a slowly changing field, explaining why the AC breakdown voltage appears to be unaffected by ageing.
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1528-1538
Aging of Environmentally Friendly Insulation Gases by Free-Burning Arcs: Technical Air
This paper investigates the effect of ageing due to free-burning arcs on the dielectric performance and the chemical composition of technical air (79% N2, 21% O2) at 1.3 bar absolute pressure. The ageing is performed by exposing the gas to a series of arcs dissipating an accumulated energy of more than 300 kJ, a level corresponding to relevant arcing energies for medium voltage load break switches. To evaluate the long-term dielectric performance, lightning impulse (LI) and power frequency AC breakdown tests are conducted in a 10 mm rod-plane gap before and after ageing. Gas decomposition is also investigated with gas chromatography coupled with mass-spectrometry. Results indicate that the LI breakdown voltage of air may enhance temporarily after arcing. This is probably due to the formation of short-lived air by-products (e.g., NO, NO2, NO3 and O3) which may reduce initial electron generation. However, changes in AC breakdown voltage might not be that significant as the presence of primary electrons is presumably guaranteed in the latter case.
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1528-1538
Aging of Environmentally Friendly Insulation Gases by Free-Burning Arcs: Technical Air
This paper investigates the effect of ageing due to free-burning arcs on the dielectric performance and the chemical composition of technical air (79% N2, 21% O2) at 1.3 bar absolute pressure. The ageing is performed by exposing the gas to a series of arcs dissipating an accumulated energy of more than 300 kJ, a level corresponding to relevant arcing energies for medium voltage load break switches. To evaluate the long-term dielectric performance, lightning impulse (LI) and power frequency AC breakdown tests are conducted in a 10 mm rod-plane gap before and after ageing. Gas decomposition is also investigated with gas chromatography coupled with mass-spectrometry. Results indicate that the LI breakdown voltage of air may enhance temporarily after arcing. This is probably due to the formation of short-lived air by-products (e.g., NO, NO2, NO3 and O3) which may reduce initial electron generation. However, changes in AC breakdown voltage might not be that significant as the presence of primary electrons is presumably guaranteed in the latter case.
- 6 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (5) , 2485-2493
Lightning Impulse Testing in Short Air-Gaps and Memory Effect of Previous Discharges
This paper reports on an observed phenomenon of increasing breakdown voltage while performing standard up and down lightning impulse (LI) testing in short air-gaps with weakly non-uniform field in an enclosed volume. The phenomenon could occur due to accumulation of space charges in the gap, changes in the chemical composition of the insulation gas, and/or changes in electrode surface due to discharges. To investigate the effect of these factors, LI tests are carried out in a 10 mm rod-plane air gap using four different methods: 1) ion flushing by DC voltage application in between LI shots, 2) with opposite polarity LI intertwined, 3) using forced air flow by a fan during the test, and 4) a reference test without any fan or voltage application. Results indicate that the phenomenon is more likely to be caused by formation of electronegative byproducts, e.g., ozone. Ozone was also experimentally detected near the test gap followed by consecutive LI breakdowns. It was found that air circulation rapidly reduces ozone concentration, which may explain why the increasing trend is not observed when a fan is used. Calculation of electron transport coefficients indicates that lack of primary electrons might be the prime reason of the increased impulse breakdown voltage of the air gap in presence of ozone.
- 6 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (5) , 2485-2493
Lightning Impulse Testing in Short Air-Gaps and Memory Effect of Previous Discharges
This paper reports on an observed phenomenon of increasing breakdown voltage while performing standard up and down lightning impulse (LI) testing in short air-gaps with weakly non-uniform field in an enclosed volume. The phenomenon could occur due to accumulation of space charges in the gap, changes in the chemical composition of the insulation gas, and/or changes in electrode surface due to discharges. To investigate the effect of these factors, LI tests are carried out in a 10 mm rod-plane air gap using four different methods: 1) ion flushing by DC voltage application in between LI shots, 2) with opposite polarity LI intertwined, 3) using forced air flow by a fan during the test, and 4) a reference test without any fan or voltage application. Results indicate that the phenomenon is more likely to be caused by formation of electronegative byproducts, e.g., ozone. Ozone was also experimentally detected near the test gap followed by consecutive LI breakdowns. It was found that air circulation rapidly reduces ozone concentration, which may explain why the increasing trend is not observed when a fan is used. Calculation of electron transport coefficients indicates that lack of primary electrons might be the prime reason of the increased impulse breakdown voltage of the air gap in presence of ozone.
- 26 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 448-451
Estimation of Frequency Stability Considering Load Levels and Load Frequency Relief
Contingencies like a generator or an interconnection trip lead to rapid decline in system frequency. In absence of sufficient reserve, under frequency load shedding is deployed in such cases to arrest the frequency excursion. In addition, frequency dependent loads such as induction and synchronous motors also exert significant influence on the frequency response of the system. Since the power consumed by these loads is proportional to their rotational speed, the total load of the system is curtailed as the frequency declines after the contingency. As such, frequency dependence of the loads, which is typically defined as load frequency relief, helps in restoring the power balance. Frequency stability of a system is also influenced by its total load level. This paper investigates the effects of load levels and load frequency relief on power system frequency stability following a major disturbance. A tool is proposed to determine the minimum point of the frequency excursion curve, commonly known as frequency nadir, for any load level and load frequency relief. The proposed tool is applied to a 7-bus, 3-generator system and it is found that the tool can successfully predict frequency nadir.
- 26 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 448-451
Estimation of Frequency Stability Considering Load Levels and Load Frequency Relief
Contingencies like a generator or an interconnection trip lead to rapid decline in system frequency. In absence of sufficient reserve, under frequency load shedding is deployed in such cases to arrest the frequency excursion. In addition, frequency dependent loads such as induction and synchronous motors also exert significant influence on the frequency response of the system. Since the power consumed by these loads is proportional to their rotational speed, the total load of the system is curtailed as the frequency declines after the contingency. As such, frequency dependence of the loads, which is typically defined as load frequency relief, helps in restoring the power balance. Frequency stability of a system is also influenced by its total load level. This paper investigates the effects of load levels and load frequency relief on power system frequency stability following a major disturbance. A tool is proposed to determine the minimum point of the frequency excursion curve, commonly known as frequency nadir, for any load level and load frequency relief. The proposed tool is applied to a 7-bus, 3-generator system and it is found that the tool can successfully predict frequency nadir.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1638-1642
Design of Intent Recognition System in a Prosthetic Leg for Automatic Switching of Locomotion Modes
Prosthetic leg is an artificial device that replaces a missing leg, which may be lost through accident, disease, or due to a condition at birth. The development of prosthetic legs has provided a solution for the rehabilitation of the amputees so that their mobility and ability to manage daily activities can be improved. But this is only possible if a smart intent recognition system is added with it. The existing electromyography-based systems are too expensive to be afforded by the mass. In this paper, a low-cost pattern recognition-based method is proposed for locomotion mode recognition (LMR) by using a combination of angular data from multiple gyroscope sensors combined with a force sensor. Three types of locomotion activities including walking, ascending and descending staircase are identified in this work. A dataset with sufficient amount of gait cycle values for each activity is developed to create the classifier model, and train and test it. Finally, the performance is assessed through both offline and online locomotion mode detection.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1638-1642
Design of Intent Recognition System in a Prosthetic Leg for Automatic Switching of Locomotion Modes
Prosthetic leg is an artificial device that replaces a missing leg, which may be lost through accident, disease, or due to a condition at birth. The development of prosthetic legs has provided a solution for the rehabilitation of the amputees so that their mobility and ability to manage daily activities can be improved. But this is only possible if a smart intent recognition system is added with it. The existing electromyography-based systems are too expensive to be afforded by the mass. In this paper, a low-cost pattern recognition-based method is proposed for locomotion mode recognition (LMR) by using a combination of angular data from multiple gyroscope sensors combined with a force sensor. Three types of locomotion activities including walking, ascending and descending staircase are identified in this work. A dataset with sufficient amount of gait cycle values for each activity is developed to create the classifier model, and train and test it. Finally, the performance is assessed through both offline and online locomotion mode detection.