Nur Aqilah Mohamad
Nur Aqilah Mohamad has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Razani Haron
High Voltage Power Energy Research, Faculty of Engineering, Universiti Malaysia Sabah, Jalan UMS, Kota Kinabalu, 88400 Sabah, Malaysia
2 shared publications - Chai Chang Yii
High Voltage Power Energy Research, Faculty of Engineering, Universiti Malaysia Sabah, Jalan UMS, Kota Kinabalu, 88400 Sabah, Malaysia
2 shared publications - Herwansyah Lago
High Voltage Power Energy Research, Faculty of Engineering, Universiti Malaysia Sabah, Jalan UMS, Kota Kinabalu, 88400 Sabah, Malaysia
2 shared publications - Markus Diantoro
Department of Physics Faculty of Mathematics and Natural Sciences Universitas Negeri Malang Malang Indonesia
2 shared publications - Megat Muhammad Ikhsan Megat Hasnan
Universiti Malaysia Sabah
2 shared publications - Pungut Ibrahim
High Voltage Power Energy Research, Faculty of Engineering, Universiti Malaysia Sabah, Jalan UMS, Kota Kinabalu, 88400 Sabah, Malaysia
2 shared publications
Latest Publications
- Open Access
- 29 August 2025
- Published by Penerbit UTM Press in ELEKTRIKA- Journal of Electrical Engineering
- Vol. 24 (2) , 149-156
Dielectric Performance of Vegetable Oil Based Silicone Dioxide and Copper Oxide Under High Temperature Ageing
This experimental study aims to ascertain the characterization of Vegetable Oil (VO) based nanofluid with SiO2 and CuO nanoparticles, the AC breakdown voltages and the partial discharge (PD) activities of mineral oil (MO) and VO based SiO2 and CuO nanofluids under high-temperature ageing. Various concentrations range of SiO2 and CuO dispersed in oil samples varied from base to 0.05%. In total, one sample of refined, bleached and deodorized palm oil (PO) and one sample of MO were measured for PD. The AC breakdown voltages measurement for all samples were carried out. Maximum PD amplitude measurements were conducted with a gap distance of 25 mm and by using needle-sphere electrode configuration for this study. The formation of SiO2 and CuO in Refined Bleached and Deodorized Palm Oil (RBDPO) is proven through the characterization using the FTIR. Then, the SiO2 and CuO nanoparticles are confirmed by using the X-ray Diffraction (XRD) and by comparing the experimental data with the Material Project software. SiO2 and CuO could improve the performance of AC breakdown voltage of MO and RBDPO for 14 and 28 days of ageing. The most significant improvements in PD activities are observed at 28 days of ageing where the maximum PD amplitude shows the highest decrement for MO based SiO2 and CuO nanofluids with 71.7% and 80.1% respectively. For RBDPO based SiO2 and CuO nanofluids provide the highest decrement at 14 days with 34.2% and 28 days with 49.5% respectively.
- 29 August 2025
- Published by Penerbit UTM Press in ELEKTRIKA- Journal of Electrical Engineering
- Vol. 24 (2) , 149-156
Open AccessDielectric Performance of Vegetable Oil Based Silicone Dioxide and Copper Oxide Under High Temperature Ageing
This experimental study aims to ascertain the characterization of Vegetable Oil (VO) based nanofluid with SiO2 and CuO nanoparticles, the AC breakdown voltages and the partial discharge (PD) activities of mineral oil (MO) and VO based SiO2 and CuO nanofluids under high-temperature ageing. Various concentrations range of SiO2 and CuO dispersed in oil samples varied from base to 0.05%. In total, one sample of refined, bleached and deodorized palm oil (PO) and one sample of MO were measured for PD. The AC breakdown voltages measurement for all samples were carried out. Maximum PD amplitude measurements were conducted with a gap distance of 25 mm and by using needle-sphere electrode configuration for this study. The formation of SiO2 and CuO in Refined Bleached and Deodorized Palm Oil (RBDPO) is proven through the characterization using the FTIR. Then, the SiO2 and CuO nanoparticles are confirmed by using the X-ray Diffraction (XRD) and by comparing the experimental data with the Material Project software. SiO2 and CuO could improve the performance of AC breakdown voltage of MO and RBDPO for 14 and 28 days of ageing. The most significant improvements in PD activities are observed at 28 days of ageing where the maximum PD amplitude shows the highest decrement for MO based SiO2 and CuO nanofluids with 71.7% and 80.1% respectively. For RBDPO based SiO2 and CuO nanofluids provide the highest decrement at 14 days with 34.2% and 28 days with 49.5% respectively.
- Open Access
- 30 October 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 126 (1) , 178-187
Brain Tumor Detection and Size Estimation using Microwave Imaging
This project focuses on developing an antenna that utilising microwave imaging technology for visualising, detecting, and estimating the size of human tumors using simulation approach. A rectangular microstrip patch antenna is chosen for its advantages of low cost, convenience, efficiency, and compactness, offering a non-ionised alternative. To meet the antenna specifications, rectangular slots are incorporated into the design. The antenna performs effectively at 7.5 GHz, exhibiting a return loss of -24.20383 dB, well below the -10 dB threshold. Placing the antenna 15 mm away from the human brain model results in a specific absorption rate (SAR) value of 0.2 W/kg for 10g, indicating its safety for brain imaging. By scanning a human head phantom with and without a tumor, the antenna captures reflected signals from different locations, enabling the generation of tumour images. A 10-mm-radius tumor is introduced to the phantom, and the unique reflected signal serves as an indicator for tumor detection, using the signal without a tumor as a reference. MATLAB software is employed for image processing, allowing the generation of tumour images and the estimation of tumor size. The simulation results demonstrate 63% accuracy in tumor size estimation. In conclusion, the antenna proves to be a safe and effective brain imaging system for tumor detection.
- 30 October 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 126 (1) , 178-187
Open AccessBrain Tumor Detection and Size Estimation using Microwave Imaging
This project focuses on developing an antenna that utilising microwave imaging technology for visualising, detecting, and estimating the size of human tumors using simulation approach. A rectangular microstrip patch antenna is chosen for its advantages of low cost, convenience, efficiency, and compactness, offering a non-ionised alternative. To meet the antenna specifications, rectangular slots are incorporated into the design. The antenna performs effectively at 7.5 GHz, exhibiting a return loss of -24.20383 dB, well below the -10 dB threshold. Placing the antenna 15 mm away from the human brain model results in a specific absorption rate (SAR) value of 0.2 W/kg for 10g, indicating its safety for brain imaging. By scanning a human head phantom with and without a tumor, the antenna captures reflected signals from different locations, enabling the generation of tumour images. A 10-mm-radius tumor is introduced to the phantom, and the unique reflected signal serves as an indicator for tumor detection, using the signal without a tumor as a reference. MATLAB software is employed for image processing, allowing the generation of tumour images and the estimation of tumor size. The simulation results demonstrate 63% accuracy in tumor size estimation. In conclusion, the antenna proves to be a safe and effective brain imaging system for tumor detection.
- Open Access
- 31 March 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 115 (1) , 131-140
Investigation Seebeck Effect of Industrial High Voltage Transformer Oil Towards Industrial Insulator Oil Condition Detection
Transformer oil serves as the main dielectric and interacts with solid insulation, encounters the environment, and conveys a lot of information. However, undesirable contamination of transformer oil like water or moisture in the transformer oil will reduce the transformer's effectiveness. This study is the first investigation of the potential of using the thermoelectric effect for transformer oil condition testing towards high voltage insulator oil condition detection. This study has found that the used oil sample with various percentages of water content produced a different Seebeck coefficient which shows the potential of using the thermoelectric effect as a simple, cheap, and versatile method to test industrial oil insulator conditions. The results of the Seebeck coefficient for each condition are 0.0003 mV/K (original), 0.0107 mV/K (4 % of water added), and 0.0131 mV/K (40 % of water added), respectively. The industrial oil shows different Seebeck magnitude between oil before and after thermal aging which show a significant decrease of Seebeck magnitude of the industrial oil insulator with an increase of thermal ageing.
- 31 March 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 115 (1) , 131-140
Open AccessInvestigation Seebeck Effect of Industrial High Voltage Transformer Oil Towards Industrial Insulator Oil Condition Detection
Transformer oil serves as the main dielectric and interacts with solid insulation, encounters the environment, and conveys a lot of information. However, undesirable contamination of transformer oil like water or moisture in the transformer oil will reduce the transformer's effectiveness. This study is the first investigation of the potential of using the thermoelectric effect for transformer oil condition testing towards high voltage insulator oil condition detection. This study has found that the used oil sample with various percentages of water content produced a different Seebeck coefficient which shows the potential of using the thermoelectric effect as a simple, cheap, and versatile method to test industrial oil insulator conditions. The results of the Seebeck coefficient for each condition are 0.0003 mV/K (original), 0.0107 mV/K (4 % of water added), and 0.0131 mV/K (40 % of water added), respectively. The industrial oil shows different Seebeck magnitude between oil before and after thermal aging which show a significant decrease of Seebeck magnitude of the industrial oil insulator with an increase of thermal ageing.