Ahmad Razani Haron
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ahmad Razani Haron has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Chai Chang Yii
High Voltage Power Energy Research, Faculty of Engineering, Universiti Malaysia Sabah, Jalan UMS, Kota Kinabalu, 88400 Sabah, Malaysia
3 shared publications - Herwansyah Lago
High Voltage Power Energy Research, Faculty of Engineering, Universiti Malaysia Sabah, Jalan UMS, Kota Kinabalu, 88400 Sabah, Malaysia
3 shared publications - Markus Diantoro
Department of Physics Faculty of Mathematics and Natural Sciences Universitas Negeri Malang Malang Indonesia
3 shared publications - Megat Muhammad Ikhsan Megat Hasnan
Universiti Malaysia Sabah
2 shared publications - Nur Aqilah Mohamad
Universiti Teknologi Malaysia UTM
2 shared publications - Pungut Ibrahim
High Voltage Power Energy Research, Faculty of Engineering, Universiti Malaysia Sabah, Jalan UMS, Kota Kinabalu, 88400 Sabah, Malaysia
2 shared publications
Latest Publications
- Open Access
- 30 October 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 126 (1) , 178-187
Brain Tumor Detection and Size Estimation using Microwave Imaging
This project focuses on developing an antenna that utilising microwave imaging technology for visualising, detecting, and estimating the size of human tumors using simulation approach. A rectangular microstrip patch antenna is chosen for its advantages of low cost, convenience, efficiency, and compactness, offering a non-ionised alternative. To meet the antenna specifications, rectangular slots are incorporated into the design. The antenna performs effectively at 7.5 GHz, exhibiting a return loss of -24.20383 dB, well below the -10 dB threshold. Placing the antenna 15 mm away from the human brain model results in a specific absorption rate (SAR) value of 0.2 W/kg for 10g, indicating its safety for brain imaging. By scanning a human head phantom with and without a tumor, the antenna captures reflected signals from different locations, enabling the generation of tumour images. A 10-mm-radius tumor is introduced to the phantom, and the unique reflected signal serves as an indicator for tumor detection, using the signal without a tumor as a reference. MATLAB software is employed for image processing, allowing the generation of tumour images and the estimation of tumor size. The simulation results demonstrate 63% accuracy in tumor size estimation. In conclusion, the antenna proves to be a safe and effective brain imaging system for tumor detection.
- 30 October 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 126 (1) , 178-187
Open AccessBrain Tumor Detection and Size Estimation using Microwave Imaging
This project focuses on developing an antenna that utilising microwave imaging technology for visualising, detecting, and estimating the size of human tumors using simulation approach. A rectangular microstrip patch antenna is chosen for its advantages of low cost, convenience, efficiency, and compactness, offering a non-ionised alternative. To meet the antenna specifications, rectangular slots are incorporated into the design. The antenna performs effectively at 7.5 GHz, exhibiting a return loss of -24.20383 dB, well below the -10 dB threshold. Placing the antenna 15 mm away from the human brain model results in a specific absorption rate (SAR) value of 0.2 W/kg for 10g, indicating its safety for brain imaging. By scanning a human head phantom with and without a tumor, the antenna captures reflected signals from different locations, enabling the generation of tumour images. A 10-mm-radius tumor is introduced to the phantom, and the unique reflected signal serves as an indicator for tumor detection, using the signal without a tumor as a reference. MATLAB software is employed for image processing, allowing the generation of tumour images and the estimation of tumor size. The simulation results demonstrate 63% accuracy in tumor size estimation. In conclusion, the antenna proves to be a safe and effective brain imaging system for tumor detection.
- Open Access
- 10 October 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- p. 232-243
Towards Enhancing Power System Protection in Distribution Systems with Distributed Generation: A Graph Theory-Based Systematic Relay Placement Approach
This manuscript presents an innovative approach to optimize power system protection through strategic relay placement in distribution systems with distributed generation (DG). Traditionally, distribution systems relied on radial configurations, assuming power flow from the grid feeder to downstream networks. However, with the integration of DG technologies, the complexity of relay placement and maintenance increases. The study aims to address protection system issues associated with connecting DGs, such as tripping of production units, blinding of protection, and undesirable islanding. The proposed methodology combines graph theory, energy not supplied (ENS) values, and relay coordination strategies to achieve reliable power system operation. The algorithm is implemented in MATLAB, utilizing data from DigSilent PowerFactory. The key constraints for relay placement, including islanding operation, relay coordination, and load priorities, are considered to minimize the number of power outages and increase overall system reliability. The effectiveness of the algorithm is demonstrated using IEEE 33-bus and 69-bus test systems under different conditions. Results show consistent and reliable relay placement locations, considering DG locations and load priorities. The algorithm's speed, effectiveness, and adaptability to different network topologies make it a promising approach for power system protection planning in distribution systems with distributed generation.
- 10 October 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- p. 232-243
Open AccessTowards Enhancing Power System Protection in Distribution Systems with Distributed Generation: A Graph Theory-Based Systematic Relay Placement Approach
This manuscript presents an innovative approach to optimize power system protection through strategic relay placement in distribution systems with distributed generation (DG). Traditionally, distribution systems relied on radial configurations, assuming power flow from the grid feeder to downstream networks. However, with the integration of DG technologies, the complexity of relay placement and maintenance increases. The study aims to address protection system issues associated with connecting DGs, such as tripping of production units, blinding of protection, and undesirable islanding. The proposed methodology combines graph theory, energy not supplied (ENS) values, and relay coordination strategies to achieve reliable power system operation. The algorithm is implemented in MATLAB, utilizing data from DigSilent PowerFactory. The key constraints for relay placement, including islanding operation, relay coordination, and load priorities, are considered to minimize the number of power outages and increase overall system reliability. The effectiveness of the algorithm is demonstrated using IEEE 33-bus and 69-bus test systems under different conditions. Results show consistent and reliable relay placement locations, considering DG locations and load priorities. The algorithm's speed, effectiveness, and adaptability to different network topologies make it a promising approach for power system protection planning in distribution systems with distributed generation.
- Open Access
- 31 March 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 115 (1) , 131-140
Investigation Seebeck Effect of Industrial High Voltage Transformer Oil Towards Industrial Insulator Oil Condition Detection
Transformer oil serves as the main dielectric and interacts with solid insulation, encounters the environment, and conveys a lot of information. However, undesirable contamination of transformer oil like water or moisture in the transformer oil will reduce the transformer's effectiveness. This study is the first investigation of the potential of using the thermoelectric effect for transformer oil condition testing towards high voltage insulator oil condition detection. This study has found that the used oil sample with various percentages of water content produced a different Seebeck coefficient which shows the potential of using the thermoelectric effect as a simple, cheap, and versatile method to test industrial oil insulator conditions. The results of the Seebeck coefficient for each condition are 0.0003 mV/K (original), 0.0107 mV/K (4 % of water added), and 0.0131 mV/K (40 % of water added), respectively. The industrial oil shows different Seebeck magnitude between oil before and after thermal aging which show a significant decrease of Seebeck magnitude of the industrial oil insulator with an increase of thermal ageing.
- 31 March 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 115 (1) , 131-140
Open AccessInvestigation Seebeck Effect of Industrial High Voltage Transformer Oil Towards Industrial Insulator Oil Condition Detection
Transformer oil serves as the main dielectric and interacts with solid insulation, encounters the environment, and conveys a lot of information. However, undesirable contamination of transformer oil like water or moisture in the transformer oil will reduce the transformer's effectiveness. This study is the first investigation of the potential of using the thermoelectric effect for transformer oil condition testing towards high voltage insulator oil condition detection. This study has found that the used oil sample with various percentages of water content produced a different Seebeck coefficient which shows the potential of using the thermoelectric effect as a simple, cheap, and versatile method to test industrial oil insulator conditions. The results of the Seebeck coefficient for each condition are 0.0003 mV/K (original), 0.0107 mV/K (4 % of water added), and 0.0131 mV/K (40 % of water added), respectively. The industrial oil shows different Seebeck magnitude between oil before and after thermal aging which show a significant decrease of Seebeck magnitude of the industrial oil insulator with an increase of thermal ageing.