Jun Lyu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jun Lyu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Hongchao Zhao
Sun Yat-sen University
2 shared publications - Jianing Wu
School of Aeronautics and Astronautics, Sun Yat-sen University, Shenzhen 518107, China
2 shared publications - Yifeng Liao
School of Aeronautics and Astronautics, Sun Yat-Sen University, Shenzhen, People’s Republic of China
2 shared publications - Yuwei Wu
School of Advanced Manufacturing, Sun Yat-Sen University, Shenzhen, People’s Republic of China
2 shared publications Guoye Chen
1 shared publicationHao Liu
Technology Innovation Institute of the Greater Bay Area, Guangzhou, Guangzhou, 510535, CHINA
1 shared publication
Latest Publications
- 24 November 2026
- Published by Elsevier in International Journal of Mechanical Sciences
Generative Inverse Design of Quasi-Zero-Stiffness Cells for Prescribed Loads
- 24 November 2026
- Published by Elsevier in International Journal of Mechanical Sciences
Generative Inverse Design of Quasi-Zero-Stiffness Cells for Prescribed Loads
- 30 December 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (2) , 025106
Flexure hinge design and optimization of a high-precision force sensor for the test mass grabbing position and release mechanism
Space-based gravitational wave detection is expected to open an observation window for gravitational wave sources in the low-frequency band. The inertial sensor is one of the key components of such detectors. To ensure that the test mass can accurately follow a geodesic trajectory, it must be precisely released within the confined vacuum chamber of the detector. This imposes specific requirements on the high integration and accuracy of contact force measurement during the grabbing and release process. This paper proposes a force sensor design employing double circular notch flexure hinges. A comparative study of single and double circular notch flexure hinge configurations reveals significant differences in terms of the distribution of maximum strain areas and the magnitude of the area-averaged strain. The double circular notch design can produce an increase in area-averaged strain of up to 351%. This study establishes a design methodology that defines a feasible range of flexure hinge parameters and their associated bonding areas. The analysis reveals that an optimal strain gauge spacing of 4–7 mm or 9-12 mm is essential for preventing bonding overlap within confined spaces. Furthermore, a force sensor calibration device was developed. Experimental characterization demonstrated that the sensor provides a full scale of 10 N, an accuracy of 0.02 N (±0.2% F.S.), a rapid response time of 12 ms, low hysteresis (0.15% F.S.) and fine repeatability (±0.2% F.S.). This study not only provides a design scheme for flexure hinge of force sensors within confined space for space-based gravitational wave detection but also presents a framework for the design of micro force sensors that satisfy the stringent requirements of aerospace and extreme industrial applications.
- 30 December 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (2) , 025106
Flexure hinge design and optimization of a high-precision force sensor for the test mass grabbing position and release mechanism
Space-based gravitational wave detection is expected to open an observation window for gravitational wave sources in the low-frequency band. The inertial sensor is one of the key components of such detectors. To ensure that the test mass can accurately follow a geodesic trajectory, it must be precisely released within the confined vacuum chamber of the detector. This imposes specific requirements on the high integration and accuracy of contact force measurement during the grabbing and release process. This paper proposes a force sensor design employing double circular notch flexure hinges. A comparative study of single and double circular notch flexure hinge configurations reveals significant differences in terms of the distribution of maximum strain areas and the magnitude of the area-averaged strain. The double circular notch design can produce an increase in area-averaged strain of up to 351%. This study establishes a design methodology that defines a feasible range of flexure hinge parameters and their associated bonding areas. The analysis reveals that an optimal strain gauge spacing of 4–7 mm or 9-12 mm is essential for preventing bonding overlap within confined spaces. Furthermore, a force sensor calibration device was developed. Experimental characterization demonstrated that the sensor provides a full scale of 10 N, an accuracy of 0.02 N (±0.2% F.S.), a rapid response time of 12 ms, low hysteresis (0.15% F.S.) and fine repeatability (±0.2% F.S.). This study not only provides a design scheme for flexure hinge of force sensors within confined space for space-based gravitational wave detection but also presents a framework for the design of micro force sensors that satisfy the stringent requirements of aerospace and extreme industrial applications.
- Open Access
- 15 April 2024
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 19 (3) , 036013
Specialized spatially-arranged non-circular fibers enhance filtration performance of African shrimp (Atya gabonensis)
African shrimp (Atya gabonensis) inhabit clear freshwaters, where the notably low concentration of food may pose a challenge to the efficacy of filter fibers on the chela for filter-feeding. Here, we investigate how the distinctive cross-sectional characteristics and spatial arrangement of the African shrimp’s non-circular fibers contribute to the enhanced filtration performance of these specialized fibers. The unilateral thickening of the wall along the long axis of the elliptical cross-section of African shrimp fibers markedly enhances the filtration performance. The staggered and twisted arrangement of the fibers optimizes the surrounding flow field, achieving a favorable balance between pressure drop and collection efficiency, consequently improving their filtration performance in collecting fine particles (diameter: 2–10 μm). Moreover, the arrangement of the fibers substantially increases the effective flow-facing filtering area of the fiber bundles, thus facilitating their efficiency in collecting larger particles (diameter > 10 μm). The unique fiber properties of the African shrimp offer novel insights for the design and optimization of new fiber-filtering robots, presenting a wide range of potential applications, such as marine in-situ resource extraction, medical filtration, and industrial filtration.
- 15 April 2024
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 19 (3) , 036013
Open AccessSpecialized spatially-arranged non-circular fibers enhance filtration performance of African shrimp (Atya gabonensis)
African shrimp (Atya gabonensis) inhabit clear freshwaters, where the notably low concentration of food may pose a challenge to the efficacy of filter fibers on the chela for filter-feeding. Here, we investigate how the distinctive cross-sectional characteristics and spatial arrangement of the African shrimp’s non-circular fibers contribute to the enhanced filtration performance of these specialized fibers. The unilateral thickening of the wall along the long axis of the elliptical cross-section of African shrimp fibers markedly enhances the filtration performance. The staggered and twisted arrangement of the fibers optimizes the surrounding flow field, achieving a favorable balance between pressure drop and collection efficiency, consequently improving their filtration performance in collecting fine particles (diameter: 2–10 μm). Moreover, the arrangement of the fibers substantially increases the effective flow-facing filtering area of the fiber bundles, thus facilitating their efficiency in collecting larger particles (diameter > 10 μm). The unique fiber properties of the African shrimp offer novel insights for the design and optimization of new fiber-filtering robots, presenting a wide range of potential applications, such as marine in-situ resource extraction, medical filtration, and industrial filtration.