Qi Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qi Wang has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Bin Yang
Shanghai Jiao Tong University
4 shared publications - Jingquan Liu
National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University 1 , Shanghai 200240
4 shared publications - Jinshi Zhao
School of Integrated Circuit Science and Engineering, Engineering Research Center of Optoelectronic Devices and Communication Technology, Ministry of Education, State Key Laboratory of Crystal Materials, Tianjin University of Technology, Tianjin 300384, People’s Republic of China
4 shared publications - Tao Ruan
Shanghai Jiao Tong University
3 shared publications Zhiyong Hu
National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Department of Micro/Nano Electronics, Shanghai Jiao Tong university, Shanghai 200240, People’s Republic of China
3 shared publications- Zhiyong Hu
Shanghai Jiao Tong University
3 shared publications
Latest Publications
- 3 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. PP (10577157) , 1-8
Hexagonal Array Piezoelectric MEMS Acoustic Sensor With High Sensitivity and Omnidirectionality
To enhance low-frequency detection sensitivity and achieve omnidirectionality in underwater acoustic sensors, this paper reports a hexagonal array piezoelectric MEMS acoustic sensor (HAAS). The HAAS comprises six identical triangular cantilever beams symmetrically arranged in a regular hexagon. This array configuration enables signal superposition to boost sensitivity, while the multi-degree-of-freedom vibrating membrane promotes omnidirectionality in underwater acoustic detection. The distinctive hexagonal array structure imparts exceptionally high sensitivity in the frequency range of 630Hz to 1.6kHz (−161.2 dB at fixed 1.6kHz,ref.1 V/ $\upmu $ Pa) and superior omnidirectional directivity, with nonuniformities of ±0.5 dB in the horizontal plane and ±0.3 dB in the vertical plane at 2 kHz. Experimental results demonstrate the substantial potential of the HAAS for applications in underwater biological activity monitoring, communication, and resource exploration.[2025-0191]
- 3 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. PP (10577157) , 1-8
Hexagonal Array Piezoelectric MEMS Acoustic Sensor With High Sensitivity and Omnidirectionality
To enhance low-frequency detection sensitivity and achieve omnidirectionality in underwater acoustic sensors, this paper reports a hexagonal array piezoelectric MEMS acoustic sensor (HAAS). The HAAS comprises six identical triangular cantilever beams symmetrically arranged in a regular hexagon. This array configuration enables signal superposition to boost sensitivity, while the multi-degree-of-freedom vibrating membrane promotes omnidirectionality in underwater acoustic detection. The distinctive hexagonal array structure imparts exceptionally high sensitivity in the frequency range of 630Hz to 1.6kHz (−161.2 dB at fixed 1.6kHz,ref.1 V/ $\upmu $ Pa) and superior omnidirectional directivity, with nonuniformities of ±0.5 dB in the horizontal plane and ±0.3 dB in the vertical plane at 2 kHz. Experimental results demonstrate the substantial potential of the HAAS for applications in underwater biological activity monitoring, communication, and resource exploration.[2025-0191]
- 1 April 2026
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 36 (4) , 045015
A nested cantilever piezoelectric MEMS speaker
To enhance the sound pressure level (SPL) and reduce the total harmonic distortion (THD) of piezoelectric micro-electro-mechanical system (MEMS) speakers, a nested cantilever piezoelectric MEMS speaker is proposed. It primarily consists of a PZT functional layer and a mica supporting layer. Measurements of the packaged device demonstrate that, compared with many reported piezoelectric MEMS speakers, the proposed nested cantilever piezoelectric MEMS speaker exhibits higher SPL in the mid-frequency range and lower THD within a continuous wider frequency range. When the driving voltage is 1 V rms , the SPL exceeds 89 dB in the frequency range of 4.3 kHz–14.1 kHz, demonstrating its potential in improving the SPL. The THD of the device remains below 1.4% within 160 Hz–20 kHz frequency range, demonstrating it features a wide applicable frequency range. The proposed piezoelectric MEMS speaker shows excellent resistance to fracture and fatigue by dropping from 5 m and playing music for 5 h. This study provides new insights into further improving SPL and reducing THD in piezoelectric MEMS speakers.
- 1 April 2026
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 36 (4) , 045015
A nested cantilever piezoelectric MEMS speaker
To enhance the sound pressure level (SPL) and reduce the total harmonic distortion (THD) of piezoelectric micro-electro-mechanical system (MEMS) speakers, a nested cantilever piezoelectric MEMS speaker is proposed. It primarily consists of a PZT functional layer and a mica supporting layer. Measurements of the packaged device demonstrate that, compared with many reported piezoelectric MEMS speakers, the proposed nested cantilever piezoelectric MEMS speaker exhibits higher SPL in the mid-frequency range and lower THD within a continuous wider frequency range. When the driving voltage is 1 V rms , the SPL exceeds 89 dB in the frequency range of 4.3 kHz–14.1 kHz, demonstrating its potential in improving the SPL. The THD of the device remains below 1.4% within 160 Hz–20 kHz frequency range, demonstrating it features a wide applicable frequency range. The proposed piezoelectric MEMS speaker shows excellent resistance to fracture and fatigue by dropping from 5 m and playing music for 5 h. This study provides new insights into further improving SPL and reducing THD in piezoelectric MEMS speakers.
- Open Access
- 5 February 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (2) , 215
A Fixed-End Beam–Cantilever Piezoelectric MEMS Speaker with Flexible Supporting Layer
Conventionally designed piezoelectric micro-electro-mechanical systems (MEMS) speakers with thin-film-type, piston-type, and cantilever-type vibration membranes still adopt a Si supporting layer, which not only hinders the improvement of sound pressure level (SPL) but also lacks characterization of reliability. In this paper, we propose a fixed-end beam–cantilever piezoelectric MEMS speaker with a flexible supporting layer, achieving an SPL comparable to that of traditional three types of piezoelectric MEMS speakers with a Si supporting layer, and displaying good reliability. The measured results performed on encapsulated prototypes mounted to an acoustic test adaptor demonstrate that under a driving voltage of 1 Vrms, the SPL exceeds 51.6 dB in the human audible frequency range of 20 Hz–20 kHz, the total harmonic distortion (THD) remains below 3.4% above 430 Hz, satisfying the basic requirements for human auditory perception. Moreover, further experiments also prove its reliability by revealing no abnormal sound output, no fracture after being dropped from heights of 1 to 5 m, and the retention of over 92% SPL following 100 h of continuous music playback. This fixed-end beam–cantilever piezoelectric MEMS speakers with a flexible supporting layer provide researchers and enterprises with brand-new design ideas and a fresh perspective, which may potentially promote their development and practical application.
- 5 February 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (2) , 215
Open AccessA Fixed-End Beam–Cantilever Piezoelectric MEMS Speaker with Flexible Supporting Layer
Conventionally designed piezoelectric micro-electro-mechanical systems (MEMS) speakers with thin-film-type, piston-type, and cantilever-type vibration membranes still adopt a Si supporting layer, which not only hinders the improvement of sound pressure level (SPL) but also lacks characterization of reliability. In this paper, we propose a fixed-end beam–cantilever piezoelectric MEMS speaker with a flexible supporting layer, achieving an SPL comparable to that of traditional three types of piezoelectric MEMS speakers with a Si supporting layer, and displaying good reliability. The measured results performed on encapsulated prototypes mounted to an acoustic test adaptor demonstrate that under a driving voltage of 1 Vrms, the SPL exceeds 51.6 dB in the human audible frequency range of 20 Hz–20 kHz, the total harmonic distortion (THD) remains below 3.4% above 430 Hz, satisfying the basic requirements for human auditory perception. Moreover, further experiments also prove its reliability by revealing no abnormal sound output, no fracture after being dropped from heights of 1 to 5 m, and the retention of over 92% SPL following 100 h of continuous music playback. This fixed-end beam–cantilever piezoelectric MEMS speakers with a flexible supporting layer provide researchers and enterprises with brand-new design ideas and a fresh perspective, which may potentially promote their development and practical application.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 35 (2) , 209-217
A Center-Bound Type Piezoelectric MEMS Speaker With Flexible Supporting Layer
Conventionally designed edge-bound type piezoelectric Micro Electro Mechanical Systems (MEMS) speakers with Si supporting layer still suffer from the problem of low sound pressure level (SPL) and high total harmonic distortion (THD). In this paper, we demonstrate a center-bound type piezoelectric MEMS speaker based on flexible supporting layer, which meets the minimum SPL requirement for human hearing, and achieves a lower THD over a wider continuous frequency band compared with the reported state-of-the-art works, and demonstrates good reliability and durability. Test results in an acoustics test adaptor show that at a driving voltage of 1 V ${}_{\mathbf {rms}}$ , greater than 52dB SPLs are obtained in the human audible range of 20Hz-20kHz, basically meeting the minimum auditory requirements for human beings. The applicable working frequency range for THD of this device spans the medium and high frequency band of 500 Hz-20 kHz. Compared with state-of-the-art reported works, it achieves a THD of $\le 5$ % over a significantly wider continuous frequency range. Moreover, this speaker produces no abnormal sound, shows no fracture after dropping from a height of 5meters, and maintain at least 90% of the SPLs after playing music continuously for 100 hours. The proposed center-bound type piezoelectric MEMS speaker with flexible supporting layer is expected to drive its own development and practical application by offering new perspectives and design concepts to researchers and enterprises. [2025-0116]
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 35 (2) , 209-217
A Center-Bound Type Piezoelectric MEMS Speaker With Flexible Supporting Layer
Conventionally designed edge-bound type piezoelectric Micro Electro Mechanical Systems (MEMS) speakers with Si supporting layer still suffer from the problem of low sound pressure level (SPL) and high total harmonic distortion (THD). In this paper, we demonstrate a center-bound type piezoelectric MEMS speaker based on flexible supporting layer, which meets the minimum SPL requirement for human hearing, and achieves a lower THD over a wider continuous frequency band compared with the reported state-of-the-art works, and demonstrates good reliability and durability. Test results in an acoustics test adaptor show that at a driving voltage of 1 V ${}_{\mathbf {rms}}$ , greater than 52dB SPLs are obtained in the human audible range of 20Hz-20kHz, basically meeting the minimum auditory requirements for human beings. The applicable working frequency range for THD of this device spans the medium and high frequency band of 500 Hz-20 kHz. Compared with state-of-the-art reported works, it achieves a THD of $\le 5$ % over a significantly wider continuous frequency range. Moreover, this speaker produces no abnormal sound, shows no fracture after dropping from a height of 5meters, and maintain at least 90% of the SPLs after playing music continuously for 100 hours. The proposed center-bound type piezoelectric MEMS speaker with flexible supporting layer is expected to drive its own development and practical application by offering new perspectives and design concepts to researchers and enterprises. [2025-0116]
- 9 January 2026
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 36 (1)
A flexible supporting layer-based cross beam-cantilever type piezoelectric MEMS speaker with reliability
The rapid progression of micro electro mechanical systems (MEMS) technology has made it possible for piezoelectric MEMS speakers to replace traditional ones. However, the traditional thin film-type, piston-type and cantilever-type piezoelectric MEMS speakers with Si supporting layer still suffer from the key problem of small sound pressure level (SPL) and reliability. In this paper, a flexible supporting layer-based cross beam-cantilever type piezoelectric MEMS speaker with reliability is proposed, which four trapezoidal cantilevers symmetrically distributed along the cross beam within a square with a side length of 4 mm, realizing a comparable SPL compared with the aforementioned traditional three types of piezoelectric MEMS ones based on Si supporting layer, and achieving good reliability. The measurement results in acoustics test adaptor show that under a driving voltage of 1 Vrms, within the range of human hearing spans from 20 Hz to 20 kHz, the SPL exceeds 50.3 dB, meeting the basic requirements for human hearing. The multiple tests also exhibit relatively consistent SPL curves, and the total harmonic distortion (THD) is less than 3.8% when the frequency is greater than 430 Hz. Furthermore, the experiments also reveal that the device does not exhibit any significant change in SPL when dropped from a height of 3 meters or when playing music continuously for 3 hours, further demonstrating its reliability. The designed cross beam-cantilever piezoelectric MEMS speaker offers fresh perspectives for researchers and enterprises, with the potential to speed up their development and practical implementation.
- 9 January 2026
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 36 (1)
A flexible supporting layer-based cross beam-cantilever type piezoelectric MEMS speaker with reliability
The rapid progression of micro electro mechanical systems (MEMS) technology has made it possible for piezoelectric MEMS speakers to replace traditional ones. However, the traditional thin film-type, piston-type and cantilever-type piezoelectric MEMS speakers with Si supporting layer still suffer from the key problem of small sound pressure level (SPL) and reliability. In this paper, a flexible supporting layer-based cross beam-cantilever type piezoelectric MEMS speaker with reliability is proposed, which four trapezoidal cantilevers symmetrically distributed along the cross beam within a square with a side length of 4 mm, realizing a comparable SPL compared with the aforementioned traditional three types of piezoelectric MEMS ones based on Si supporting layer, and achieving good reliability. The measurement results in acoustics test adaptor show that under a driving voltage of 1 Vrms, within the range of human hearing spans from 20 Hz to 20 kHz, the SPL exceeds 50.3 dB, meeting the basic requirements for human hearing. The multiple tests also exhibit relatively consistent SPL curves, and the total harmonic distortion (THD) is less than 3.8% when the frequency is greater than 430 Hz. Furthermore, the experiments also reveal that the device does not exhibit any significant change in SPL when dropped from a height of 3 meters or when playing music continuously for 3 hours, further demonstrating its reliability. The designed cross beam-cantilever piezoelectric MEMS speaker offers fresh perspectives for researchers and enterprises, with the potential to speed up their development and practical implementation.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
An Axisymmetric Bionic Seal Whisker-Type Piezoelectric MEMS Vector Hydrophone
MEMS vector hydrophones are poised to become the core devices of miniaturized underwater acoustic sensing. However, existing MEMS vector hydrophones suffer from low sensitivity and shallow concave point depth, which hinders long-range detection. In this work, we present an axisymmetric bionic seal whisker–type piezoelectric MEMS vector hydrophone (ASWVH) that leverages bioinspired geometries and stress-concentration regions to amplify piezoelectric output, yielding enhanced directivity and high sensitivity. The optimal microstructure dimensions for ASWVH were determined using COMSOL 5.6 simulations. The biomimetic seal whisker structure not only ensures an operational frequency bandwidth of 20–2000 Hz but also expands the effective acoustic reception area, thereby further enhancing sensitivity. The unique wavy bionic sealing whisker shape provides high sensitivity, and the measured X-axis and Y-axis sensitivities are -171.7 dB and -173.2 dB@2 kHz (re. 1 V/μPa), respectively. Moreover, the device exhibits an exceptional “8”-shaped directivity pattern with concave point depth exceeding 40 dB in both channels, rendering it well-suited for high-precision passive underwater detection.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
An Axisymmetric Bionic Seal Whisker-Type Piezoelectric MEMS Vector Hydrophone
MEMS vector hydrophones are poised to become the core devices of miniaturized underwater acoustic sensing. However, existing MEMS vector hydrophones suffer from low sensitivity and shallow concave point depth, which hinders long-range detection. In this work, we present an axisymmetric bionic seal whisker–type piezoelectric MEMS vector hydrophone (ASWVH) that leverages bioinspired geometries and stress-concentration regions to amplify piezoelectric output, yielding enhanced directivity and high sensitivity. The optimal microstructure dimensions for ASWVH were determined using COMSOL 5.6 simulations. The biomimetic seal whisker structure not only ensures an operational frequency bandwidth of 20–2000 Hz but also expands the effective acoustic reception area, thereby further enhancing sensitivity. The unique wavy bionic sealing whisker shape provides high sensitivity, and the measured X-axis and Y-axis sensitivities are -171.7 dB and -173.2 dB@2 kHz (re. 1 V/μPa), respectively. Moreover, the device exhibits an exceptional “8”-shaped directivity pattern with concave point depth exceeding 40 dB in both channels, rendering it well-suited for high-precision passive underwater detection.
- 1 May 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (5) , 055022
Unveiling intrinsic superconductivity in HfNbZrTi medium-entropy alloy single crystals
Medium and high entropy alloys (MEAs and HEAs) have emerged as promising materials in materials science and engineering, offering exceptional mechanical properties and intriguing low-temperature physical characteristics. In the study of superconducting mechanisms, high-quality, large single crystals are essential for obtaining reliable experimental data. Here, we report the first successful growth of high-quality MEA HfNbZrTi single crystals using the Floating Zone Method and present a comprehensive investigation of their superconducting properties, vortex dynamics, and specific heat. Notably, the specific heat jump extracted from experimental data yields ΔC/γT c = 1.43, while the superconducting gap Δ(0) is 0.92 meV, precisely matching the theoretical prediction of the weak-coupling Bardeen–Cooper–Schrieffer model. Furthermore, we report the first investigation of magnetic relaxation in MEA single crystals, revealing an exceptionally low relaxation rate (S < 0.02 at 2 K). These findings not only provide strong experimental evidence supporting the application of MEAs and HEAs superconductors but also open new avenues for the development of superconductors with ultralow magnetic relaxation rates.
- 1 May 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (5) , 055022
Unveiling intrinsic superconductivity in HfNbZrTi medium-entropy alloy single crystals
Medium and high entropy alloys (MEAs and HEAs) have emerged as promising materials in materials science and engineering, offering exceptional mechanical properties and intriguing low-temperature physical characteristics. In the study of superconducting mechanisms, high-quality, large single crystals are essential for obtaining reliable experimental data. Here, we report the first successful growth of high-quality MEA HfNbZrTi single crystals using the Floating Zone Method and present a comprehensive investigation of their superconducting properties, vortex dynamics, and specific heat. Notably, the specific heat jump extracted from experimental data yields ΔC/γT c = 1.43, while the superconducting gap Δ(0) is 0.92 meV, precisely matching the theoretical prediction of the weak-coupling Bardeen–Cooper–Schrieffer model. Furthermore, we report the first investigation of magnetic relaxation in MEA single crystals, revealing an exceptionally low relaxation rate (S < 0.02 at 2 K). These findings not only provide strong experimental evidence supporting the application of MEAs and HEAs superconductors but also open new avenues for the development of superconductors with ultralow magnetic relaxation rates.
- 1 April 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (14)
A sandwich pMUT for the amplification of ultrasound transmission and reception
Piezoelectric micromachined ultrasound transducers (pMUTs) are essential for ultrasonic communication as well as energy harvesting and transmission. While pMUTs typically demonstrate lower energy conversion efficiency and narrower bandwidths compared to traditional sandwich ultrasound transducers, their larger counterparts often present size constraints in specific applications. This paper introduces a sandwich pMUT (SpMUT) designed to enhance ultrasound transmission and reception. The SpMUT features a silicon substrate with a scandium aluminum nitride thin film, a dual electrode layer, and a three dimensional printed horn. The horn acts as a mechanical intermediary, amplifying the mechanical strain generated by the piezoelectric layer or an external sound field. Our experiments yielded a fractional bandwidth of −6 dB at 107% with a center frequency of 421 kHz in water. By optimizing the ratio of the horn's back and front diameters, we achieved maximum amplification factors of 8.59 for transmission and 8.1 for reception. The SpMUT shows significant potential for enhanced ultrasound signal amplification in biomedical and nondestructive testing applications.
- 1 April 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (14)
A sandwich pMUT for the amplification of ultrasound transmission and reception
Piezoelectric micromachined ultrasound transducers (pMUTs) are essential for ultrasonic communication as well as energy harvesting and transmission. While pMUTs typically demonstrate lower energy conversion efficiency and narrower bandwidths compared to traditional sandwich ultrasound transducers, their larger counterparts often present size constraints in specific applications. This paper introduces a sandwich pMUT (SpMUT) designed to enhance ultrasound transmission and reception. The SpMUT features a silicon substrate with a scandium aluminum nitride thin film, a dual electrode layer, and a three dimensional printed horn. The horn acts as a mechanical intermediary, amplifying the mechanical strain generated by the piezoelectric layer or an external sound field. Our experiments yielded a fractional bandwidth of −6 dB at 107% with a center frequency of 421 kHz in water. By optimizing the ratio of the horn's back and front diameters, we achieved maximum amplification factors of 8.59 for transmission and 8.1 for reception. The SpMUT shows significant potential for enhanced ultrasound signal amplification in biomedical and nondestructive testing applications.
- 14 May 2024
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 34 (6) , 065003
Unsealed piezoelectric MEMS speaker with rigid-flexible composite membrane
In this paper, we propose an unsealed piezoelectric microelectromechanical systems (MEMS) speaker with rigid-flexible composite membrane, which can eliminate the membrane separation and the vibration displacement limitation at high driving voltage compared to that with the sealed rigid-flexible coupling membrane demonstrated in our previous work. Measurements performed on encapsulated prototypes mounted to an artificial ear simulator have revealed that in the human audible range of 20 Hz–20 kHz, higher than 68.5 dB SPLs are obtained at 2 V, and greater than 89.6 dB SPLs are achieved at 10 V. Moreover, the SPL distribution and effective SPLs at each moment when playing the same song exhibit similar characteristics to those of a commercial electromagnetic one. This piezoelectric MEMS speaker achieves high SPLs meeting the basic hearing needs of the human, and will have excellent prospects for future wearable audio electronics.
- 14 May 2024
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 34 (6) , 065003
Unsealed piezoelectric MEMS speaker with rigid-flexible composite membrane
In this paper, we propose an unsealed piezoelectric microelectromechanical systems (MEMS) speaker with rigid-flexible composite membrane, which can eliminate the membrane separation and the vibration displacement limitation at high driving voltage compared to that with the sealed rigid-flexible coupling membrane demonstrated in our previous work. Measurements performed on encapsulated prototypes mounted to an artificial ear simulator have revealed that in the human audible range of 20 Hz–20 kHz, higher than 68.5 dB SPLs are obtained at 2 V, and greater than 89.6 dB SPLs are achieved at 10 V. Moreover, the SPL distribution and effective SPLs at each moment when playing the same song exhibit similar characteristics to those of a commercial electromagnetic one. This piezoelectric MEMS speaker achieves high SPLs meeting the basic hearing needs of the human, and will have excellent prospects for future wearable audio electronics.