M del Mar Pérez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
M del Mar Pérez has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Georg Zechner
Bundesamt für Eich- und Vermessungswesen (BEV), Arltgasse 35, A-1160 Wien, Austria
2 shared publications - Michael Matus
Bundesamt für Eich- und Vermessungswesen (BEV), Arltgasse 35, A-1160 Wien, Austria
2 shared publications A Duță
National Institute of Metrology (INM), Sos. Vitan-Bârzesti 11, 042122 Bucuresti, Romania
1 shared publication- Alessandro Germak
INRiM, National Institute of Metrological Research, 10135 Torino, Italy
1 shared publication - Andrew J. Lancaster
JAI, Department of Physics, University of Oxford, DWB, Keble Road, Oxford, OX1 3RH, UK
1 shared publication - Andrew J. Lewis
National Physical Laboratory (NPL)
1 shared publication
Latest Publications
- 1 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1A)
Report on EURAMET supplementary comparison on measurement of a 1 mm stage micrometer
Main text: The results of the EURAMET supplementary comparison on the calibration of a 1 mm stage micrometer are reported. 13 NMIs from 4 RMOs participated in the comparison. Originally, the comparison was planned to use a single artefact. Because it was destroyed during the duration of the comparison, it was necessary to carry out the test in two loops using a new artefact. Artefact circulation started in August 2020 and was completed in September 2022. Both artefacts were the same make and kind. The two artefacts are standard stage micrometers as used in optical microscopy on a transparent, low thermal expansion substrate. The scale length is 1 mm divided in 100 parts. The distances of all 100 scale marks from the zero mark have been measured by each participant. The results with associated uncertainties of all participating NMIs were in good agreement. All En values were smaller than 1 already from the pre-draft A state on. Therefore, no separate analysis of a largest consistent subset was necessary. With 1400 values without a single outlier, it is tempting to assume that uncertainty contributions are somehow overestimated. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1A)
Report on EURAMET supplementary comparison on measurement of a 1 mm stage micrometer
Main text: The results of the EURAMET supplementary comparison on the calibration of a 1 mm stage micrometer are reported. 13 NMIs from 4 RMOs participated in the comparison. Originally, the comparison was planned to use a single artefact. Because it was destroyed during the duration of the comparison, it was necessary to carry out the test in two loops using a new artefact. Artefact circulation started in August 2020 and was completed in September 2022. Both artefacts were the same make and kind. The two artefacts are standard stage micrometers as used in optical microscopy on a transparent, low thermal expansion substrate. The scale length is 1 mm divided in 100 parts. The distances of all 100 scale marks from the zero mark have been measured by each participant. The results with associated uncertainties of all participating NMIs were in good agreement. All En values were smaller than 1 already from the pre-draft A state on. Therefore, no separate analysis of a largest consistent subset was necessary. With 1400 values without a single outlier, it is tempting to assume that uncertainty contributions are somehow overestimated. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1A)
The CCL-K11 ongoing key comparison. Final report for 2023
Main text: Six lasers from six national metrological institutes (NMIs) were compared in the year 2023 as part of the CCL-K11 ongoing key comparison, initiated by the 13th meeting of the Comité Consultative des Longueurs (CCL) in 2007. The absolute frequency of theses lasers was measured in three different node laboratories following the technical protocol for CCL-K11. All are practical realisations of the definition of the metre according to the MeP for the definition of the metre. Five standards are He-Ne-lasers stabilized on the f component of the R(127) 11-5 transitions of molecular iodine 127I2 with a wavelength of approximately 633 nm. The sixth standard is a fibre laser stabilized to the P(16) (ν1+ν3) transition of molecular acetylene 13C2H2 with a wavelength of approximately 1542 nm. The technical protocol was deliberately designed to accommodate artefacts of different wavelengths in a common framework. The results of these measurements are compiled in the present report. The comparison reports, as communicated by each participant, are included in the main document. This document constitutes the thirteenth final report for the ongoing key comparison CCL-K11. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1A)
The CCL-K11 ongoing key comparison. Final report for 2023
Main text: Six lasers from six national metrological institutes (NMIs) were compared in the year 2023 as part of the CCL-K11 ongoing key comparison, initiated by the 13th meeting of the Comité Consultative des Longueurs (CCL) in 2007. The absolute frequency of theses lasers was measured in three different node laboratories following the technical protocol for CCL-K11. All are practical realisations of the definition of the metre according to the MeP for the definition of the metre. Five standards are He-Ne-lasers stabilized on the f component of the R(127) 11-5 transitions of molecular iodine 127I2 with a wavelength of approximately 633 nm. The sixth standard is a fibre laser stabilized to the P(16) (ν1+ν3) transition of molecular acetylene 13C2H2 with a wavelength of approximately 1542 nm. The technical protocol was deliberately designed to accommodate artefacts of different wavelengths in a common framework. The results of these measurements are compiled in the present report. The comparison reports, as communicated by each participant, are included in the main document. This document constitutes the thirteenth final report for the ongoing key comparison CCL-K11. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).