Troy N. Tully
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Troy N. Tully has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jacob A. George
Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT, USA
3 shared publications - Caleb J. Thomson
Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
2 shared publications - David J. Warren
Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT, USA
2 shared publications - Gregory A. Clark
Biomedical Engineering, University of Utah, 36 S Wasatch Dr, Salt Lake City, Utah, 84112, UNITED STATES
2 shared publications Amelia E. Nelson
Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT, USA
1 shared publication- Christian Morrell
Institute of Biomedical Engineering, University of New Brunswick Institute of Biomedical Engineering, New Brunswick, Fredericton, New Brunswick, E3B 5A3, CANADA
1 shared publication
Latest Publications
- Open Access
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 3784-3792
Training Movement Velocity Significantly Affects the Performance of Myoelectric Control
Our native hands are uniquely capable of operating across a wide range of speeds and forces. In contrast, most commercial myoelectric prostheses typically provide limited speed and force output. One approach to endow myoelectric prostheses with variable speed and/or force output is to use continuous kinematic positions of the prosthesis based on electromyography (EMG). Within the field of machine learning, it is well established that homogeneous training data can lead to bias that negatively impacts the run-time performance of the algorithm. Yet, most continuous decoders are trained on a homogeneous dataset involving only a single kinematic speed. To this end, we systematically investigated how different training speeds influence myoelectric control with two common continuous decoders on multiple performance metrics. We compared a Kalman filter (KF) and Convolutional Long Short-Term Memory (C-LSTM) neural network trained on slow, medium, fast, and mixed-speed datasets, evaluating their performance in offline analyses and in two real-time online tasks with the user actively in the loop. We found that training speed significantly affected algorithm performance, but effects were often algorithm dependent. Linear algorithms, like the KF, are likely to exhibit lower unintended movement errors and smoother control when trained on slow-speed data but will also struggle to generalize to higher movement speeds. In contrast, nonlinear algorithms like the C-LSTM can likely provide greater adaptability, with mixed-speed training leading to improved accuracy and task success rates across conditions. Although an often-overlooked implicit parameter, these findings explicitly demonstrate that a lack of diverse training speeds in existing myoelectric control training paradigms leads to worse decoder performance. By incorporating a range of movement speeds into training protocols or decoder design, myoelectric continuous decoders could achieve more dexterous and robust control, potentially improving prosthetic usability and retention.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 3784-3792
Open AccessTraining Movement Velocity Significantly Affects the Performance of Myoelectric Control
Our native hands are uniquely capable of operating across a wide range of speeds and forces. In contrast, most commercial myoelectric prostheses typically provide limited speed and force output. One approach to endow myoelectric prostheses with variable speed and/or force output is to use continuous kinematic positions of the prosthesis based on electromyography (EMG). Within the field of machine learning, it is well established that homogeneous training data can lead to bias that negatively impacts the run-time performance of the algorithm. Yet, most continuous decoders are trained on a homogeneous dataset involving only a single kinematic speed. To this end, we systematically investigated how different training speeds influence myoelectric control with two common continuous decoders on multiple performance metrics. We compared a Kalman filter (KF) and Convolutional Long Short-Term Memory (C-LSTM) neural network trained on slow, medium, fast, and mixed-speed datasets, evaluating their performance in offline analyses and in two real-time online tasks with the user actively in the loop. We found that training speed significantly affected algorithm performance, but effects were often algorithm dependent. Linear algorithms, like the KF, are likely to exhibit lower unintended movement errors and smoother control when trained on slow-speed data but will also struggle to generalize to higher movement speeds. In contrast, nonlinear algorithms like the C-LSTM can likely provide greater adaptability, with mixed-speed training leading to improved accuracy and task success rates across conditions. Although an often-overlooked implicit parameter, these findings explicitly demonstrate that a lack of diverse training speeds in existing myoelectric control training paradigms leads to worse decoder performance. By incorporating a range of movement speeds into training protocols or decoder design, myoelectric continuous decoders could achieve more dexterous and robust control, potentially improving prosthetic usability and retention.
- Open Access
- 29 November 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (6) , 066020
Enhancing neuroprosthesis calibration: the advantage of integrating prior training over exclusive use of new data
Objective. Neuroprostheses typically operate under supervised learning, in which a machine-learning algorithm is trained to correlate neural or myoelectric activity with an individual’s motor intent. Due to the stochastic nature of neuromyoelectric signals, algorithm performance decays over time. This decay is accelerated when attempting to regress proportional control of multiple joints in parallel, compared with the more typical classification-based pattern recognition control. To overcome this degradation, neuroprostheses and commercial myoelectric prostheses are often recalibrated and retrained frequently so that only the most recent, up-to-date data influences the algorithm performance. Here, we introduce and validate an alternative training paradigm in which training data from past calibrations is aggregated and reused in future calibrations for regression control. Approach. Using a cohort of four transradial amputees implanted with intramuscular electromyographic recording leads, we demonstrate that aggregating prior datasets improves prosthetic regression-based control in offline analyses and an online human-in-the-loop task. In offline analyses, we compared the performance of a convolutional neural network (CNN) and a modified Kalman filter (MKF) to simultaneously regress the kinematics of an eight-degree-of-freedom prosthesis. Both algorithms were trained under the traditional paradigm using a single dataset, as well as under the new paradigm using aggregated datasets from the past five or ten trainings. Main results. Dataset aggregation reduced the root-mean-squared error (RMSE) of algorithm estimates for both the CNN and MKF, although the CNN saw a greater reduction in error. Further offline analyses revealed that dataset aggregation improved CNN robustness when reusing the same algorithm on subsequent test days, as indicated by a smaller increase in RMSE per day. Finally, data from an online virtual-target-touching task with one amputee showed significantly better real-time prosthetic control when using aggregated training data from just two prior datasets. Significance. Altogether, these results demonstrate that training data from past calibrations should not be discarded but, rather, should be reused in an aggregated training dataset such that the increased amount and diversity of data improve algorithm performance. More broadly, this work supports a paradigm shift for the field of neuroprostheses away from daily data recalibration for linear classification models and towards daily data aggregation for non-linear regression models.
- 29 November 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (6) , 066020
Open AccessEnhancing neuroprosthesis calibration: the advantage of integrating prior training over exclusive use of new data
Objective. Neuroprostheses typically operate under supervised learning, in which a machine-learning algorithm is trained to correlate neural or myoelectric activity with an individual’s motor intent. Due to the stochastic nature of neuromyoelectric signals, algorithm performance decays over time. This decay is accelerated when attempting to regress proportional control of multiple joints in parallel, compared with the more typical classification-based pattern recognition control. To overcome this degradation, neuroprostheses and commercial myoelectric prostheses are often recalibrated and retrained frequently so that only the most recent, up-to-date data influences the algorithm performance. Here, we introduce and validate an alternative training paradigm in which training data from past calibrations is aggregated and reused in future calibrations for regression control. Approach. Using a cohort of four transradial amputees implanted with intramuscular electromyographic recording leads, we demonstrate that aggregating prior datasets improves prosthetic regression-based control in offline analyses and an online human-in-the-loop task. In offline analyses, we compared the performance of a convolutional neural network (CNN) and a modified Kalman filter (MKF) to simultaneously regress the kinematics of an eight-degree-of-freedom prosthesis. Both algorithms were trained under the traditional paradigm using a single dataset, as well as under the new paradigm using aggregated datasets from the past five or ten trainings. Main results. Dataset aggregation reduced the root-mean-squared error (RMSE) of algorithm estimates for both the CNN and MKF, although the CNN saw a greater reduction in error. Further offline analyses revealed that dataset aggregation improved CNN robustness when reusing the same algorithm on subsequent test days, as indicated by a smaller increase in RMSE per day. Finally, data from an online virtual-target-touching task with one amputee showed significantly better real-time prosthetic control when using aggregated training data from just two prior datasets. Significance. Altogether, these results demonstrate that training data from past calibrations should not be discarded but, rather, should be reused in an aggregated training dataset such that the increased amount and diversity of data improve algorithm performance. More broadly, this work supports a paradigm shift for the field of neuroprostheses away from daily data recalibration for linear classification models and towards daily data aggregation for non-linear regression models.
- Open Access
- 3 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 2124-2133
A Multimodal Assistive-Robotic-Arm Control System to Increase Independence After Tetraplegia
Following tetraplegia, independence for completing essential daily tasks, such as opening doors and eating, significantly declines. Assistive robotic manipulators (ARMs) could restore independence, but typically input devices for these manipulators require functional use of the hands. We created and validated a hands-free multimodal input system for controlling an ARM in virtual reality using combinations of a gyroscope, eye-tracking, and heterologous surface electromyography (sEMG). These input modalities are mapped to ARM functions based on the user’s preferences and to maximize the utility of their residual volitional capabilities following tetraplegia. The two participants in this study with tetraplegia preferred to use the control mapping with sEMG button functions and disliked winking commands. Non-disabled participants were more varied in their preferences and performance, further suggesting that customizability is an advantageous component of the control system. Replacing buttons from a traditional handheld controller with sEMG did not substantively reduce performance. The system provided adequate control to all participants to complete functional tasks in virtual reality such as opening door handles, turning stove dials, eating, and drinking, all of which enable independence and improved quality of life for these individuals.
- 3 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 2124-2133
Open AccessA Multimodal Assistive-Robotic-Arm Control System to Increase Independence After Tetraplegia
Following tetraplegia, independence for completing essential daily tasks, such as opening doors and eating, significantly declines. Assistive robotic manipulators (ARMs) could restore independence, but typically input devices for these manipulators require functional use of the hands. We created and validated a hands-free multimodal input system for controlling an ARM in virtual reality using combinations of a gyroscope, eye-tracking, and heterologous surface electromyography (sEMG). These input modalities are mapped to ARM functions based on the user’s preferences and to maximize the utility of their residual volitional capabilities following tetraplegia. The two participants in this study with tetraplegia preferred to use the control mapping with sEMG button functions and disliked winking commands. Non-disabled participants were more varied in their preferences and performance, further suggesting that customizability is an advantageous component of the control system. Replacing buttons from a traditional handheld controller with sEMG did not substantively reduce performance. The system provided adequate control to all participants to complete functional tasks in virtual reality such as opening door handles, turning stove dials, eating, and drinking, all of which enable independence and improved quality of life for these individuals.
- Open Access
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 1974-1983
Validity and Impact of Methods for Collecting Training Data for Myoelectric Prosthetic Control Algorithms
Intuitive regression control of prostheses relies on training algorithms to correlate biological recordings to motor intent. The quality of the training dataset is critical to run-time regression performance, but accurately labeling intended hand kinematics after hand amputation is challenging. In this study, we quantified the accuracy and precision of labeling hand kinematics using two common training paradigms: 1) mimic training, where participants mimic predetermined motions of a prosthesis, and 2) mirror training, where participants mirror their contralateral intact hand during synchronized bilateral movements. We first explored this question in healthy non-amputee individuals where the ground-truth kinematics could be readily determined using motion capture. Kinematic data showed that mimic training fails to account for biomechanical coupling and temporal changes in hand posture. Additionally, mirror training exhibited significantly higher accuracy and precision in labeling hand kinematics. These findings suggest that the mirror training approach generates a more faithful, albeit more complex, dataset. Accordingly, mirror training resulted in significantly better offline regression performance when using a large amount of training data and a non-linear neural network. Next, we explored these different training paradigms online, with a cohort of unilateral transradial amputees actively controlling a prosthesis in real-time to complete a functional task. Overall, we found that mirror training resulted in significantly faster task completion speeds and similar subjective workload. These results demonstrate that mirror training can potentially provide more dexterous control through the utilization of task-specific, user-selected training data. Consequently, these findings serve as a valuable guide for the next generation of myoelectric and neuroprostheses leveraging machine learning to provide more dexterous and intuitive control.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 1974-1983
Open AccessValidity and Impact of Methods for Collecting Training Data for Myoelectric Prosthetic Control Algorithms
Intuitive regression control of prostheses relies on training algorithms to correlate biological recordings to motor intent. The quality of the training dataset is critical to run-time regression performance, but accurately labeling intended hand kinematics after hand amputation is challenging. In this study, we quantified the accuracy and precision of labeling hand kinematics using two common training paradigms: 1) mimic training, where participants mimic predetermined motions of a prosthesis, and 2) mirror training, where participants mirror their contralateral intact hand during synchronized bilateral movements. We first explored this question in healthy non-amputee individuals where the ground-truth kinematics could be readily determined using motion capture. Kinematic data showed that mimic training fails to account for biomechanical coupling and temporal changes in hand posture. Additionally, mirror training exhibited significantly higher accuracy and precision in labeling hand kinematics. These findings suggest that the mirror training approach generates a more faithful, albeit more complex, dataset. Accordingly, mirror training resulted in significantly better offline regression performance when using a large amount of training data and a non-linear neural network. Next, we explored these different training paradigms online, with a cohort of unilateral transradial amputees actively controlling a prosthesis in real-time to complete a functional task. Overall, we found that mirror training resulted in significantly faster task completion speeds and similar subjective workload. These results demonstrate that mirror training can potentially provide more dexterous control through the utilization of task-specific, user-selected training data. Consequently, these findings serve as a valuable guide for the next generation of myoelectric and neuroprostheses leveraging machine learning to provide more dexterous and intuitive control.