ASAmra Skopljak-Beganović

Amra Skopljak-Beganović

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Amra Skopljak-Beganović has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • UTICAJ REKONSTRUKCIONIH PARAMETARA NA KVALITET SLIKE I KVANTIFIKACIJU U PET/CT SNIMANJU KORIŠTENJEM FANTOMA SA PČELINJIM VOSKOM

    by Safet Hadžimusić, Amela Begić, Adnan Beganović, Šejla Cerić, Amra Skopljak-Beganović, Nusret Salkica, Selma Agić-Bilalagić, Ajla Arnautović-Halimić, Belma Tukić

    Uvod: Tjelesna masa značajno utiče na vrijednosti standardizovanog preuzimanja radiofarmaka (SUV) u PET/CT dijagnostici, zbog čega postoji potreba za preciznijim metodama kvantifikacije. U ovom istraživanju razvijen je dodatni modul od pčelinjeg voska koji je postavljen na standardni NEMA IQ fantom s ciljem simulacije povećane tjelesne mase pacijenata. Pčelinji vosak je odabran zbog svojih fizičkih i radioloških karakteristika koje su slične masnom tkivu. Metode: PET/CT snimanja provedena su korištenjem standardnog fantoma, kao i fantoma obloženog slojem pčelinjeg voska, uz primjenu identičnih niskodoznih protokola snimanja. Rekonstrukcija podataka izvršena je primjenom tri različite rekonstrukcione metode. Kvantitativna analiza bila je usmjerena na preuzimanje ¹⁸F-FDG u četiri „vruće“ sfere promjera od 10 do 37 mm. Posebna pažnja posvećena je parametrima SUVmax i SUVmean kako bi se procijenio uticaj modula od pčelinjeg voska na tačnost i ponovljivost mjerenja. Rezultati: Uočene su značajne razlike u SUV vrijednostima između standardnog fantoma i fantoma sa dodatnim slojem pčelinjeg voska, naročito pri primjeni različitih rekonstrukcionih parametara. Dobijeni rezultati potvrđuju da modul od pčelinjeg voska predstavlja pouzdan model za simulaciju povećane tjelesne mase te ukazuju na njegov potencijal u optimizaciji PET/CT protokola kod pacijenata sa povećanom tjelesnom težinom i gojaznošću. Zaključak: Vrijednosti SUVmean bile su više kod fantoma sa dodatkom pčelinjeg voska, što ukazuje na uticaj povećane tjelesne mase na kvantifikaciju PET signala. Međutim, korekcija na nemasnu tjelesnu masu (SUVlbm) značajno je smanjila ove razlike, potvrđujući da se uočen efekat prvenstveno odnosi na način izračuna SUV vrijednosti, a ne na stvarnu koncentraciju radiofarmaka. Rezultati naglašavaju važnost primjene odgovarajućih korekcija SUV parametara te podržavaju razvoj preciznijih PET/CT protokola prilagođenih promjenama tjelesne kompozicije, posebno u praćenju onkoloških pacijenata. Modul od pčelinjeg voska pokazao se kao jednostavan i praktičan alat za unapređenje kvantifikacije PET/CT nalaza kod različitih kategorija pacijenata.

  • Clinical Potential of F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Radiomics in Breast Cancer: Our Experience

    by Nusret Salkica, Renata Milardović, Halil Ćorović, Safet Hadžimusić, Amra Skopljak-Beganović, Enis Tinjak, Mirjana Ristanić Beroš

  • Open Access

    Impact of age and body mass index on dual-energy X-ray absorptiometry scan results in postmenopausal women

    by Halil Ćorović, Nusret Salkica, Naida Omerović Ćorović, Šejla Cerić, Selma Agić-Bilalagić, Amra Skopljak-Beganović, Enis Tinjak

    Aim To analyse the impact of age and body mass index (BMI) on dual-energy X-ray absorptiometry (DXA) scan results in postmenopausal women. Methods The study included 100 postmenopausal women who underwent the DXA procedure, out of which 50 had a normal BMI and 50 were overweight/obese. Data that were examined included age, BMI, T-score of the lumbar region and the femoral neck, as well as bone mineral density (BMD). Correlation results were presented as Pearson’s correlation coefficient (r). Results The T2-score and BMD2 were significantly lower in older patients compared to younger ones (p=0.008 and p=0.007, respectively). Post hoc test results showed that the T2-score and BMD2 were significantly lower in patients ≥71 years of age compared to patients ≤59 years of age (p=0.006 and p=0.005, respectively). Also, T1- and T2-scores, as well as BMD1 and BMD2, were significantly higher in overweight/obese patients (p<0.001 and p=0.003; p<0.001 and p=0.002, respectively). The correlation between BMI and the T1-score was moderate (r=0.429), between BMI and the T2-score weak (r=0.348), between BMI and BMD1 moderate (r=0.431), and between BMI and BMD2 weak (r=0.344). Conclusion Our study showed that both age and BMI are important factors affecting DXA procedures and should be taken into account with each postmenopausal woman individually in everyday practice.

  • Open Access

    Optimisation of the bone single photon emission computed tomography in oncology patients

    by Nusret Salkica, Amela Begić, Adnan Beganović, Fuad Julardžija, Adnan Šehić, Halil Ćorović, Safet Hadžimusić, Amra Skopljak-Beganović

    Introduction: The introduction of hybrid imaging systems such as Single Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) has completely changed the scanning procedure of conventional diagnostic nuclear medicine protocols. Modern bone scintigraphy protocols include SUV quanitification and Whole Body (WB) SPECT/CT scanning modality. The major limitation of these new technologies is relatively long scanning time. New detector systems with modern reconstruction softwares have been developed for fast scanning SPECT protocolos. These new technologies can produce images of reduced acquisition with same quality as full scanning acquisition. As a result new studies suggest that planar WB scintigraphy should be replaced with WB SPECT/CT. Methods: One hundred oncology patients performed SPECT/CT as a part as their clinical follow-up. Three different scanning and three reconstruction protocols have been evaluated. Two nuclear medicine physicians evaluated with Likert scale image sharpness, lesion visibility, and lesion background detectability. The overall image quality was determined as the sum of these three parameters. Results: In terms of scan duration reduction on image quality, Volumetrix Evolution for Bone performed during ultra-fast SPECT acquisition achieved the highest score, which is superior compared to the standard SPECT acquisition protocol. The overall image quality was the best with the Volumetrix MI Evolution for Bone protocol for ultra-fast acquisition Conclusion: The Evolution for Bone protocol for ultra-fast acquisition showed best results compared to other protocols. The adoption of new acquisition SPECT protocol may offer more comfortable exams, resulting in higher patient satisfaction. The implementation of this new protocol can lead to an improvement in SPECT sensitivity, primarily due to the reduction of SPECT motion artifacts.

  • Radiation Exposure of Patients in Neonatal Intensive Care Unit

    by Adnan Beganović, Irmina Sefić-Pašić, Maja Gazdić-Šantić, Rahima Jašić, Amra Skopljak-Beganović, Adnan Šehić, Sandra Vegar-Zubović

  • Evaluation of Computed Tomography X-Ray Beam Dose Profiles

    by Lejla M. Čiva, Adnan Beganović, Mahira Redžić, Ivan Lasić, Maja Gazdić-Šantić, Amra Skopljak-Beganović, Rahima Jašić, Sandra Vegar-Zubović