Safet Hadžimusić
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Safet Hadžimusić has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Nusret Salkica
Klinika za nuklearnu medicinu, Klinički centar Univerziteta u Sarajevu, Sarajevo, Bosna i Hercegovina; Univerzitet u Sarajevu, Fakultet zdravstvenih studija, Sarajevo, Bosna i Hercegovina
5 shared publications - Amra Skopljak-Beganović
Clinical Centre of Sarajevo University
3 shared publications - Halil Ćorović
Clinical Centre University of Sarajevo, Sarajevo, Bosnia and Herzegovina
3 shared publications Amela Begić
Department for PET/CT, Nuclear Medicine Clinic, Clinical Center of Sarajevo University, Sarajevo, Bosnia and Herzegovina; Department of Radiology Technologies, Faculty of Health Studies, University of Sarajevo, Sarajevo, Bosnia and Herzegovina
2 shared publications- Enis Tinjak
Univerzitet u Sarajevu, Fakultet zdravstvenih studija, Sarajevo, Bosna i Hercegovina; Klinika za Onkologiju, Klinički centar Univerziteta u Sarajevu, Sarajevo, Bosna i Hercegovina
2 shared publications - Šejla Cerić
Klinika za nuklearnu medicinu, Klinički centar Univerziteta u Sarajevu, Sarajevo, Bosna i Hercegovina
2 shared publications
Latest Publications
- 18 October 2026
- Published by University of Sarajevo Faculty of Health Sciences in Konferencija radioloških tehnoogija s međunarodnim učešćem - CORT
- Vol. 2 (1) , 13
UTICAJ REKONSTRUKCIONIH PARAMETARA NA KVALITET SLIKE I KVANTIFIKACIJU U PET/CT SNIMANJU KORIŠTENJEM FANTOMA SA PČELINJIM VOSKOM
Uvod: Tjelesna masa značajno utiče na vrijednosti standardizovanog preuzimanja radiofarmaka (SUV) u PET/CT dijagnostici, zbog čega postoji potreba za preciznijim metodama kvantifikacije. U ovom istraživanju razvijen je dodatni modul od pčelinjeg voska koji je postavljen na standardni NEMA IQ fantom s ciljem simulacije povećane tjelesne mase pacijenata. Pčelinji vosak je odabran zbog svojih fizičkih i radioloških karakteristika koje su slične masnom tkivu. Metode: PET/CT snimanja provedena su korištenjem standardnog fantoma, kao i fantoma obloženog slojem pčelinjeg voska, uz primjenu identičnih niskodoznih protokola snimanja. Rekonstrukcija podataka izvršena je primjenom tri različite rekonstrukcione metode. Kvantitativna analiza bila je usmjerena na preuzimanje ¹⁸F-FDG u četiri „vruće“ sfere promjera od 10 do 37 mm. Posebna pažnja posvećena je parametrima SUVmax i SUVmean kako bi se procijenio uticaj modula od pčelinjeg voska na tačnost i ponovljivost mjerenja. Rezultati: Uočene su značajne razlike u SUV vrijednostima između standardnog fantoma i fantoma sa dodatnim slojem pčelinjeg voska, naročito pri primjeni različitih rekonstrukcionih parametara. Dobijeni rezultati potvrđuju da modul od pčelinjeg voska predstavlja pouzdan model za simulaciju povećane tjelesne mase te ukazuju na njegov potencijal u optimizaciji PET/CT protokola kod pacijenata sa povećanom tjelesnom težinom i gojaznošću. Zaključak: Vrijednosti SUVmean bile su više kod fantoma sa dodatkom pčelinjeg voska, što ukazuje na uticaj povećane tjelesne mase na kvantifikaciju PET signala. Međutim, korekcija na nemasnu tjelesnu masu (SUVlbm) značajno je smanjila ove razlike, potvrđujući da se uočen efekat prvenstveno odnosi na način izračuna SUV vrijednosti, a ne na stvarnu koncentraciju radiofarmaka. Rezultati naglašavaju važnost primjene odgovarajućih korekcija SUV parametara te podržavaju razvoj preciznijih PET/CT protokola prilagođenih promjenama tjelesne kompozicije, posebno u praćenju onkoloških pacijenata. Modul od pčelinjeg voska pokazao se kao jednostavan i praktičan alat za unapređenje kvantifikacije PET/CT nalaza kod različitih kategorija pacijenata.
- 18 October 2026
- Published by University of Sarajevo Faculty of Health Sciences in Konferencija radioloških tehnoogija s međunarodnim učešćem - CORT
- Vol. 2 (1) , 13
UTICAJ REKONSTRUKCIONIH PARAMETARA NA KVALITET SLIKE I KVANTIFIKACIJU U PET/CT SNIMANJU KORIŠTENJEM FANTOMA SA PČELINJIM VOSKOM
Uvod: Tjelesna masa značajno utiče na vrijednosti standardizovanog preuzimanja radiofarmaka (SUV) u PET/CT dijagnostici, zbog čega postoji potreba za preciznijim metodama kvantifikacije. U ovom istraživanju razvijen je dodatni modul od pčelinjeg voska koji je postavljen na standardni NEMA IQ fantom s ciljem simulacije povećane tjelesne mase pacijenata. Pčelinji vosak je odabran zbog svojih fizičkih i radioloških karakteristika koje su slične masnom tkivu. Metode: PET/CT snimanja provedena su korištenjem standardnog fantoma, kao i fantoma obloženog slojem pčelinjeg voska, uz primjenu identičnih niskodoznih protokola snimanja. Rekonstrukcija podataka izvršena je primjenom tri različite rekonstrukcione metode. Kvantitativna analiza bila je usmjerena na preuzimanje ¹⁸F-FDG u četiri „vruće“ sfere promjera od 10 do 37 mm. Posebna pažnja posvećena je parametrima SUVmax i SUVmean kako bi se procijenio uticaj modula od pčelinjeg voska na tačnost i ponovljivost mjerenja. Rezultati: Uočene su značajne razlike u SUV vrijednostima između standardnog fantoma i fantoma sa dodatnim slojem pčelinjeg voska, naročito pri primjeni različitih rekonstrukcionih parametara. Dobijeni rezultati potvrđuju da modul od pčelinjeg voska predstavlja pouzdan model za simulaciju povećane tjelesne mase te ukazuju na njegov potencijal u optimizaciji PET/CT protokola kod pacijenata sa povećanom tjelesnom težinom i gojaznošću. Zaključak: Vrijednosti SUVmean bile su više kod fantoma sa dodatkom pčelinjeg voska, što ukazuje na uticaj povećane tjelesne mase na kvantifikaciju PET signala. Međutim, korekcija na nemasnu tjelesnu masu (SUVlbm) značajno je smanjila ove razlike, potvrđujući da se uočen efekat prvenstveno odnosi na način izračuna SUV vrijednosti, a ne na stvarnu koncentraciju radiofarmaka. Rezultati naglašavaju važnost primjene odgovarajućih korekcija SUV parametara te podržavaju razvoj preciznijih PET/CT protokola prilagođenih promjenama tjelesne kompozicije, posebno u praćenju onkoloških pacijenata. Modul od pčelinjeg voska pokazao se kao jednostavan i praktičan alat za unapređenje kvantifikacije PET/CT nalaza kod različitih kategorija pacijenata.
- 18 October 2026
- Published by University of Sarajevo Faculty of Health Sciences in Konferencija radioloških tehnoogija s međunarodnim učešćem - CORT
- Vol. 2 (1) , 12
UTICAJ APLIKACIJE RADIOFARMACEUTIKA NA KVALITET NUKLEARNOMEDICINSKIH SNIMAKA
Radiofarmaci imaju ključnu ulogu u nuklearnoj medicini jer omogućavaju prikaz funkcionalnih i metaboličkih procesa u organizmu. Kvalitet nuklearnomedicinskih snimaka direktno zavisi od pravilnog izbora radiofarmaceutika, njegove pripreme i aplikacije. Faktori kao što su aplicirana aktivnost, radiohemijska čistoća, metoda aplikacije, vrijeme između aplikacije i snimanja te fiziološke karakteristike pacijenta značajno utiču na raspodjelu radiofarmaka i kvalitet dobivenih nuklearnomedicinskih slika. Pravilna aplikacija radiofarmaceutika omogućava optimalnu biodistribuciju radiofarmaka, povećava odnos signal–šum i doprinosi boljoj rezoluciji i kontrastu snimaka. Nepravilna aplikacija može dovesti do pojave artefakata, smanjene dijagnostičke tačnosti, neadekvatne kvantifikacije i/ili pogrešne interpretacije nalaza. Poseban značaj imaju ekstravazacija radiofarmaka, neadekvatna priprema pacijenta i odstupanja od standardiziranih protokola, koji negativno utiču na kvalitet nuklearnomedicinskih snimaka. Savremene nuklearnomedicinske metode, poput SPECT i PET dijagnostike, naročito zahtijevaju preciznu i standardiziranu primjenu radiofarmaceutika kako bi se osigurali pouzdani dijagnostički rezultati uz minimalnu izloženost pacijenta jonizirajućem zračenju. Cilj ovog rada je ukazati na značaj pravilne aplikacije radiofarmaka kao i analizirati faktore koji utiču na kvalitet nuklearnomedicinskih snimaka. Razumijevanje ovih faktora doprinosi unapređenju dijagnostičke tačnosti, sigurnosti pacijenata i ukupnog kvaliteta nuklearnomedicinskih procedura.
- 18 October 2026
- Published by University of Sarajevo Faculty of Health Sciences in Konferencija radioloških tehnoogija s međunarodnim učešćem - CORT
- Vol. 2 (1) , 12
UTICAJ APLIKACIJE RADIOFARMACEUTIKA NA KVALITET NUKLEARNOMEDICINSKIH SNIMAKA
Radiofarmaci imaju ključnu ulogu u nuklearnoj medicini jer omogućavaju prikaz funkcionalnih i metaboličkih procesa u organizmu. Kvalitet nuklearnomedicinskih snimaka direktno zavisi od pravilnog izbora radiofarmaceutika, njegove pripreme i aplikacije. Faktori kao što su aplicirana aktivnost, radiohemijska čistoća, metoda aplikacije, vrijeme između aplikacije i snimanja te fiziološke karakteristike pacijenta značajno utiču na raspodjelu radiofarmaka i kvalitet dobivenih nuklearnomedicinskih slika. Pravilna aplikacija radiofarmaceutika omogućava optimalnu biodistribuciju radiofarmaka, povećava odnos signal–šum i doprinosi boljoj rezoluciji i kontrastu snimaka. Nepravilna aplikacija može dovesti do pojave artefakata, smanjene dijagnostičke tačnosti, neadekvatne kvantifikacije i/ili pogrešne interpretacije nalaza. Poseban značaj imaju ekstravazacija radiofarmaka, neadekvatna priprema pacijenta i odstupanja od standardiziranih protokola, koji negativno utiču na kvalitet nuklearnomedicinskih snimaka. Savremene nuklearnomedicinske metode, poput SPECT i PET dijagnostike, naročito zahtijevaju preciznu i standardiziranu primjenu radiofarmaceutika kako bi se osigurali pouzdani dijagnostički rezultati uz minimalnu izloženost pacijenta jonizirajućem zračenju. Cilj ovog rada je ukazati na značaj pravilne aplikacije radiofarmaka kao i analizirati faktore koji utiču na kvalitet nuklearnomedicinskih snimaka. Razumijevanje ovih faktora doprinosi unapređenju dijagnostičke tačnosti, sigurnosti pacijenata i ukupnog kvaliteta nuklearnomedicinskih procedura.
- Open Access
- 25 February 2024
- Published by University of Sarajevo Faculty of Health Sciences in Journal of Health Sciences
- Vol. 13 (3 (Supleme) , 209-212
Optimisation of the bone single photon emission computed tomography in oncology patients
Introduction: The introduction of hybrid imaging systems such as Single Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) has completely changed the scanning procedure of conventional diagnostic nuclear medicine protocols. Modern bone scintigraphy protocols include SUV quanitification and Whole Body (WB) SPECT/CT scanning modality. The major limitation of these new technologies is relatively long scanning time. New detector systems with modern reconstruction softwares have been developed for fast scanning SPECT protocolos. These new technologies can produce images of reduced acquisition with same quality as full scanning acquisition. As a result new studies suggest that planar WB scintigraphy should be replaced with WB SPECT/CT. Methods: One hundred oncology patients performed SPECT/CT as a part as their clinical follow-up. Three different scanning and three reconstruction protocols have been evaluated. Two nuclear medicine physicians evaluated with Likert scale image sharpness, lesion visibility, and lesion background detectability. The overall image quality was determined as the sum of these three parameters. Results: In terms of scan duration reduction on image quality, Volumetrix Evolution for Bone performed during ultra-fast SPECT acquisition achieved the highest score, which is superior compared to the standard SPECT acquisition protocol. The overall image quality was the best with the Volumetrix MI Evolution for Bone protocol for ultra-fast acquisition Conclusion: The Evolution for Bone protocol for ultra-fast acquisition showed best results compared to other protocols. The adoption of new acquisition SPECT protocol may offer more comfortable exams, resulting in higher patient satisfaction. The implementation of this new protocol can lead to an improvement in SPECT sensitivity, primarily due to the reduction of SPECT motion artifacts.
- 25 February 2024
- Published by University of Sarajevo Faculty of Health Sciences in Journal of Health Sciences
- Vol. 13 (3 (Supleme) , 209-212
Open AccessOptimisation of the bone single photon emission computed tomography in oncology patients
Introduction: The introduction of hybrid imaging systems such as Single Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) has completely changed the scanning procedure of conventional diagnostic nuclear medicine protocols. Modern bone scintigraphy protocols include SUV quanitification and Whole Body (WB) SPECT/CT scanning modality. The major limitation of these new technologies is relatively long scanning time. New detector systems with modern reconstruction softwares have been developed for fast scanning SPECT protocolos. These new technologies can produce images of reduced acquisition with same quality as full scanning acquisition. As a result new studies suggest that planar WB scintigraphy should be replaced with WB SPECT/CT. Methods: One hundred oncology patients performed SPECT/CT as a part as their clinical follow-up. Three different scanning and three reconstruction protocols have been evaluated. Two nuclear medicine physicians evaluated with Likert scale image sharpness, lesion visibility, and lesion background detectability. The overall image quality was determined as the sum of these three parameters. Results: In terms of scan duration reduction on image quality, Volumetrix Evolution for Bone performed during ultra-fast SPECT acquisition achieved the highest score, which is superior compared to the standard SPECT acquisition protocol. The overall image quality was the best with the Volumetrix MI Evolution for Bone protocol for ultra-fast acquisition Conclusion: The Evolution for Bone protocol for ultra-fast acquisition showed best results compared to other protocols. The adoption of new acquisition SPECT protocol may offer more comfortable exams, resulting in higher patient satisfaction. The implementation of this new protocol can lead to an improvement in SPECT sensitivity, primarily due to the reduction of SPECT motion artifacts.
- 1 January 2022
- Published by University of Sarajevo Faculty of Health Sciences in Konferencija radioloških tehnoogija s međunarodnim učešćem - CORT
- p. 14-15
Tehnološke inovacije u nuklearnoj medicini
Nuklearna medicina je medicinska specijalnost koja koristi radiofarmaceutike za dijagnostičke i terapijske postupke. Dijagnostičke mogućnosti nuklearne medicine temelje se na snimanju funkcionalnih i molekularnih puteva kod različitih bolesti korištenjem specifičnih modaliteta snimanja kao što su: jednofotonska emisiona kompjuterska tomografija (SPECT) i pozitronska emisiona tomografija (PET). Nedavni tehnološki napredak zahtijevao je uvođenje hibridnih uređaja. Ovi hibridni uređaji su multimodalne kamere u kojima su dva različita sistema za skeniranje smještena u jednom portalu. Najčešće korišteni hibridni uređaji su SPECT/CT i PET/CT, dok je PET/MRI rezervisan za velike kliničke istraživačke centre. Hibridni skeneri su u potpunosti revolucionirali nuklearnu medicinu. Dalji razvoj medicinskih uređaja zahtijevao je nove digitalne sisteme kao što su kadmijum cink telurid (CZT SPECT) i digitalni PET detektori u obliku čvrstih silikonskih pločica. Brojanje fotona i pozitrona u ovim novim sistemima je vrlo brzo, precizno i bez elektronskog šuma koji se javlja u analognim sistemima. Nedavni razvoj softverske tehnologije doveo je do novih algoritama rekonstrukcije: modaliteti Resolution Recovery (RR) za SPECT i Time of Flight (TOF) za PET. Ovi algoritmi u kombinaciji sa novim digitalnim sistemima omogućavaju smanjenje radioaktivne doze ili vremena skeniranja uz održavanje kvaliteta slike. Drugi tehnološki napredak unapređuje nove protokole akvizicije i rekonstrukcije sa posebnim naglaskom na SPECT / CT cijelog tijela, kvantifikaciju SPECT / CT, dinamičku PET / CT studiju i Total body PET / CT metodologiju. Pored poboljšanja opreme za nuklearnu medicinu, nedavna dostignuća u radiofarmaciji PET i SPECT dovode do poboljšane osjetljivosti i specifičnosti kod raznih onkoloških i neonkoloških bolesti, uključujući neurologiju, kardiologiju i druge. Cilj rada je prikaz tehnološkog napretka u nuklearnoj medicini kroz nove smjernice za snimanje, preliminarna klinička ispitivanja ili evaluaciju potencijalnog kliničkog utjecaja modernih pristupa slikanju sa SPECT/CT, PET/CT i PET/MRI, kao i nove radioaktivne markere.
- 1 January 2022
- Published by University of Sarajevo Faculty of Health Sciences in Konferencija radioloških tehnoogija s međunarodnim učešćem - CORT
- p. 14-15
Tehnološke inovacije u nuklearnoj medicini
Nuklearna medicina je medicinska specijalnost koja koristi radiofarmaceutike za dijagnostičke i terapijske postupke. Dijagnostičke mogućnosti nuklearne medicine temelje se na snimanju funkcionalnih i molekularnih puteva kod različitih bolesti korištenjem specifičnih modaliteta snimanja kao što su: jednofotonska emisiona kompjuterska tomografija (SPECT) i pozitronska emisiona tomografija (PET). Nedavni tehnološki napredak zahtijevao je uvođenje hibridnih uređaja. Ovi hibridni uređaji su multimodalne kamere u kojima su dva različita sistema za skeniranje smještena u jednom portalu. Najčešće korišteni hibridni uređaji su SPECT/CT i PET/CT, dok je PET/MRI rezervisan za velike kliničke istraživačke centre. Hibridni skeneri su u potpunosti revolucionirali nuklearnu medicinu. Dalji razvoj medicinskih uređaja zahtijevao je nove digitalne sisteme kao što su kadmijum cink telurid (CZT SPECT) i digitalni PET detektori u obliku čvrstih silikonskih pločica. Brojanje fotona i pozitrona u ovim novim sistemima je vrlo brzo, precizno i bez elektronskog šuma koji se javlja u analognim sistemima. Nedavni razvoj softverske tehnologije doveo je do novih algoritama rekonstrukcije: modaliteti Resolution Recovery (RR) za SPECT i Time of Flight (TOF) za PET. Ovi algoritmi u kombinaciji sa novim digitalnim sistemima omogućavaju smanjenje radioaktivne doze ili vremena skeniranja uz održavanje kvaliteta slike. Drugi tehnološki napredak unapređuje nove protokole akvizicije i rekonstrukcije sa posebnim naglaskom na SPECT / CT cijelog tijela, kvantifikaciju SPECT / CT, dinamičku PET / CT studiju i Total body PET / CT metodologiju. Pored poboljšanja opreme za nuklearnu medicinu, nedavna dostignuća u radiofarmaciji PET i SPECT dovode do poboljšane osjetljivosti i specifičnosti kod raznih onkoloških i neonkoloških bolesti, uključujući neurologiju, kardiologiju i druge. Cilj rada je prikaz tehnološkog napretka u nuklearnoj medicini kroz nove smjernice za snimanje, preliminarna klinička ispitivanja ili evaluaciju potencijalnog kliničkog utjecaja modernih pristupa slikanju sa SPECT/CT, PET/CT i PET/MRI, kao i nove radioaktivne markere.