BZBingnan Zhan

Bingnan Zhan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bingnan Zhan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Novel Angle Standard Using Time Grating With an Accuracy of ±0.005${}^{\prime\prime}$

    by Bingnan Zhan, Chong Chen, Zhicheng Yu, Xiaokang Liu, Peiyu Yu, Changliang Wu

    Angle, as a fundamental physical quantity, has been jointly proposed by several countries as the eighth fundamental unit in the International System of Units (SIs). However, angle standard for metrological traceability and traceback has stagnated in terms of resolution and uncertainty for 20 years. To address this, we proposed a novel associated constraint sensing principle featuring two concentric, coaxial time gratings within a common plane, replacing traditional dual optical gratings to eliminate concentricity variation during relative rotation. Building on this, a self-calibration and accuracy iterative evolution method was introduced, capitalizing on mutual reference and cross-verification characteristics to the dual time grating configuration. This enables continuous accuracy verification and improvement without higher accuracy reference instruments. Thus, the time grating angle standard device prototype has surpassed the current highest metrology level.

  • Open Access

    Research on the Scheme of Secondary Re-Modulation Based on Time Grating

    by Bingnan Zhan, Changliang Wu, Xiaokang Liu, Pei Huang, Peiyu Yu

    This paper proposed a new type of time grating which adopts the two-stage secondary re-modulation scheme, where the output signals from the first-stage induction electrodes are applied as the excitation signals to the second-stage excitation electrodes, so that the second stage induction electrodes generate the traveling wave output signals with effective measurement period. The measurement period over the full measurement range of the sensor is increased from N to 2N, and the resolution of the sensor is doubled. The second level induction electrode adopts a differential structure design, which can effectively reduce common mode interference, improve the anti-interference ability and measurement accuracy of the sensor, and achieve high-resolution and high-precision angular displacement measurement. Experimental results have shown that this scheme can achieve high-precision displacement measurement.

  • An integrated high precision absolute angular displacement sensor

    by Bingnan Zhan, Changliang Wu, Xiaokang Liu, Pei Huang, Peiyu Yu

    This paper proposed a high precision absolute angular displacement time grating sensor, and was assembled into an integrated encoder. This absolute angle sensor contains two incremental sensors with N 1 and N 2 measurement period, respectively. N 1 and N 2 are mutually prime, and N 1 > N 2. The induction electrodes of the fine measurement component adopt differential design to minimize the effects of external electromagnetic interference and common mode interference between different sensing units so as to achieve high precision displacement measurement, the phase difference between two incremental sensor is used for absolute positioning. This absolute positioning method reduces the installation requirements and enhances their absolute positioning capability, enhancing adaptability and application prospects. The reflecting ring design simplifies the structure of the encoder and facilitates sensor integration. The induction output signals of different components are cross connected through lead wires to the reflecting ring far away from the measurement component to the first harmonic error during the measurement period. The reading heads adopt a round, uniformly distributed design scheme, and the average effect of the whole circumference closed ring sampling scheme is beneficial for improving measurement accuracy, reduce the influence of edge effects and parasitic capacitance on nonlinear errors within the measurement period and eliminating harmonic errors. A sensor prototype with a diameter of 83 mm was manufactured and assembled into an integrated encoder. Experimental results show that the sensor achieve a precision of 12″ over a full 360° measurement range and a resolution of 0.5″, and it can realize absolute positioning.


  • A Novel Self-Calibration Method for Ultrahigh-Precision Angular Displacement Measurement

    by Bingnan Zhan, Pei Huang, Xiaokang Liu, Jianhua Liu, Changliang Wu

    This paper proposes a new self-calibration method for ultra-high precision angular displacement measurement, called the association constrained relative rotation self-calibration method. The combined sensor applied in this method consists of two independent sensors, one serves as reference benchmark and the other performs association constrained relative rotation. The method is achieved by controlling two sensors with a double-bearing turntable for multiple interlocking rotations and relative rotations. Two sensors are concentric and coaxial, and the axis center will not be inconsistent due to the shaft rotation in the operation condition. The reading heads have a round, uniformly distributed design on the rotor substrate, satisfy the circular closure principle, and without accumulated error. All reading heads can be processed and formed at one time on the substrate face by manufacturing methods. Thus, the consistency and the position accuracy of the reading heads can be guaranteed by manufacturing processes. The average effect of the whole circumference closed ring sampling scheme can improve the sensor performance and can reduce the influence of axial and radial runout errors of the rotation shaft system on the measurement results. The measurement accuracy after self-calibration is about ±0.03", which is much better than the sensor measurement accuracy before self-calibration. The comparative experiments with the polygon mirror and an autocollimator, it can be seen that the association constrained relative rotation self-calibration method is effective, and the combined sensor will also be used in the development of angle benchmarks in the future.