Peiyu Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peiyu Yu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bingnan Zhan
School of Mechanical Engineering, Beijing Institute of Technology, Beijing, China
2 shared publications - Changliang Wu
School of Mechanical Engineering, Beijing Institute of Technology, Beijing, China
2 shared publications - Xiaokang Liu
Engineering Research Center of Mechanical Testing Technology and Equipment (Ministry of Education), Chongqing University of Technology, Chongqing 400054, China
2 shared publications - Chong Chen
Engineering Research Center of Mechanical Testing Technology and Equipment (Ministry of Education), Chongqing University of Technology, Chongqing, China
1 shared publication - Jianhua Liu
School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, P. R. China
1 shared publication - Pei Huang
School of Mechanical Engineering, Beijing Institute of Technology, Beijing, China
1 shared publication
Latest Publications
- 17 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-11
A Novel Angle Standard Using Time Grating With an Accuracy of ±0.005${}^{\prime\prime}$
Angle, as a fundamental physical quantity, has been jointly proposed by several countries as the eighth fundamental unit in the International System of Units (SIs). However, angle standard for metrological traceability and traceback has stagnated in terms of resolution and uncertainty for 20 years. To address this, we proposed a novel associated constraint sensing principle featuring two concentric, coaxial time gratings within a common plane, replacing traditional dual optical gratings to eliminate concentricity variation during relative rotation. Building on this, a self-calibration and accuracy iterative evolution method was introduced, capitalizing on mutual reference and cross-verification characteristics to the dual time grating configuration. This enables continuous accuracy verification and improvement without higher accuracy reference instruments. Thus, the time grating angle standard device prototype has surpassed the current highest metrology level.
- 17 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-11
A Novel Angle Standard Using Time Grating With an Accuracy of ±0.005${}^{\prime\prime}$
Angle, as a fundamental physical quantity, has been jointly proposed by several countries as the eighth fundamental unit in the International System of Units (SIs). However, angle standard for metrological traceability and traceback has stagnated in terms of resolution and uncertainty for 20 years. To address this, we proposed a novel associated constraint sensing principle featuring two concentric, coaxial time gratings within a common plane, replacing traditional dual optical gratings to eliminate concentricity variation during relative rotation. Building on this, a self-calibration and accuracy iterative evolution method was introduced, capitalizing on mutual reference and cross-verification characteristics to the dual time grating configuration. This enables continuous accuracy verification and improvement without higher accuracy reference instruments. Thus, the time grating angle standard device prototype has surpassed the current highest metrology level.