Changliang Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Changliang Wu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Xiaokang Liu
Engineering Research Center of Mechanical Testing Technology and Equipment (Ministry of Education), Chongqing University of Technology, Chongqing 400054, China
3 shared publications - Bingnan Zhan
School of Mechanical Engineering, Beijing Institute of Technology, Beijing, China
2 shared publications - Peiyu Yu
School of Mechanical Engineering, Beijing Institute of Technology, Beijing, China
2 shared publications - Zhicheng Yu
Engineering Research Center of Mechanical Testing Technology and Equipment (Ministry of Education), Chongqing University of Technology, Chongqing, China
2 shared publications - Chong Chen
Engineering Research Center of Mechanical Testing Technology and Equipment (Ministry of Education), Chongqing University of Technology, Chongqing, China
1 shared publication - Jianhua Liu
School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, P. R. China
1 shared publication
Latest Publications
- 17 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-11
A Novel Angle Standard Using Time Grating With an Accuracy of ±0.005${}^{\prime\prime}$
Angle, as a fundamental physical quantity, has been jointly proposed by several countries as the eighth fundamental unit in the International System of Units (SIs). However, angle standard for metrological traceability and traceback has stagnated in terms of resolution and uncertainty for 20 years. To address this, we proposed a novel associated constraint sensing principle featuring two concentric, coaxial time gratings within a common plane, replacing traditional dual optical gratings to eliminate concentricity variation during relative rotation. Building on this, a self-calibration and accuracy iterative evolution method was introduced, capitalizing on mutual reference and cross-verification characteristics to the dual time grating configuration. This enables continuous accuracy verification and improvement without higher accuracy reference instruments. Thus, the time grating angle standard device prototype has surpassed the current highest metrology level.
- 17 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-11
A Novel Angle Standard Using Time Grating With an Accuracy of ±0.005${}^{\prime\prime}$
Angle, as a fundamental physical quantity, has been jointly proposed by several countries as the eighth fundamental unit in the International System of Units (SIs). However, angle standard for metrological traceability and traceback has stagnated in terms of resolution and uncertainty for 20 years. To address this, we proposed a novel associated constraint sensing principle featuring two concentric, coaxial time gratings within a common plane, replacing traditional dual optical gratings to eliminate concentricity variation during relative rotation. Building on this, a self-calibration and accuracy iterative evolution method was introduced, capitalizing on mutual reference and cross-verification characteristics to the dual time grating configuration. This enables continuous accuracy verification and improvement without higher accuracy reference instruments. Thus, the time grating angle standard device prototype has surpassed the current highest metrology level.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (8) , 12031-12039
A Self-Calibration Method for Angular Displacement Capacitive Time-Grating Sensors Using a Multi-Head Combination
In this paper, a self-calibration method for angular displacement capacitive time‑grating sensors based on a multi-reading-head configuration is proposed. The method employs three reading-headsets with specific arrangements—bisection (R1, R5), trisection (R1, R3, R7), and quintisection (R1, R2, R4, R6, R8)—whose average outputs serve as three distinct internal reference benchmarks. Each benchmark is used separately to perform error detection on the reading head being calibrated. Specific harmonic components are extracted from the resulting error curves via spectral analysis. These harmonic components are compensated for in the head’s output using a harmonic reconstruction algorithm, thereby achieving sensor self-calibration. All of the reading heads are monolithically integrated on a single substrate using a one-step manufacturing process. This integration ensures performance consistency and precise layout alignment among the heads while significantly mitigating the effects of installation errors and head-to-head variations. The experimental results demonstrated that the self-calibrated sensor achieved a measurement accuracy of ±0.15", which represented an improvement of approximately 99.5% over the single-head accuracy of ±30". The self-calibration outcome was consistent with the external reference-based calibration results. The proposed method requires no external high-precision data, features a simple structure and high calibration efficiency, and is thus suitable for deployment in complex industrial environments.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (8) , 12031-12039
A Self-Calibration Method for Angular Displacement Capacitive Time-Grating Sensors Using a Multi-Head Combination
In this paper, a self-calibration method for angular displacement capacitive time‑grating sensors based on a multi-reading-head configuration is proposed. The method employs three reading-headsets with specific arrangements—bisection (R1, R5), trisection (R1, R3, R7), and quintisection (R1, R2, R4, R6, R8)—whose average outputs serve as three distinct internal reference benchmarks. Each benchmark is used separately to perform error detection on the reading head being calibrated. Specific harmonic components are extracted from the resulting error curves via spectral analysis. These harmonic components are compensated for in the head’s output using a harmonic reconstruction algorithm, thereby achieving sensor self-calibration. All of the reading heads are monolithically integrated on a single substrate using a one-step manufacturing process. This integration ensures performance consistency and precise layout alignment among the heads while significantly mitigating the effects of installation errors and head-to-head variations. The experimental results demonstrated that the self-calibrated sensor achieved a measurement accuracy of ±0.15", which represented an improvement of approximately 99.5% over the single-head accuracy of ±30". The self-calibration outcome was consistent with the external reference-based calibration results. The proposed method requires no external high-precision data, features a simple structure and high calibration efficiency, and is thus suitable for deployment in complex industrial environments.