Fouad Haddad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fouad Haddad has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Peiwen Li
Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ 85721, USA
2 shared publications - Ye Zhang
University of Arizona Department of Aerospace and Mechanical Engineering Tucson, AZ 85721
1 shared publication
Latest Publications
- 24 May 2024
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 147 (1) , 1-14
Analysis of Heat Transfer of Molten Salts Startup Flow in Cold Pipes Avoiding Freezing in Solar and Nuclear Energy Systems
Molten salts are employed as the heat transfer fluid to carry the thermal energy from a solar receiver or a nuclear reactor for delivering to thermal storage systems or thermal power plants for power generation. For the startup operation, molten salts need to be pumped to flow into the pipes which may have lower temperature than the freezing point of molten salt due to the cold ambient temperature overnight or over the suspension of operation. Preventing the freezing of molten salt in cold pipes becomes a critical issue to the safe operation of a concentrating solar thermal power plant or a molten salt nuclear power plant. This study conducted a basic heat transfer analysis of the transient heat transfer from flowing molten salt to a cold pipe to determine the length from entrance to the onset of freezing of the fluid. From our modeling and analytical solution using method of characteristics, the correlation of the location of onset of freezing of molten salt with respect to the flow velocity, heat capacities of molten salt and pipes, dimension of the pipes, and the initial temperatures of salts and pipes, have been understood clearly. The modeling and computational tool can fundamentally help engineers to design a system to avoid freezing and clogging at cold startup when molten salt is applied as a heat transfer fluid.
- 24 May 2024
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 147 (1) , 1-14
Analysis of Heat Transfer of Molten Salts Startup Flow in Cold Pipes Avoiding Freezing in Solar and Nuclear Energy Systems
Molten salts are employed as the heat transfer fluid to carry the thermal energy from a solar receiver or a nuclear reactor for delivering to thermal storage systems or thermal power plants for power generation. For the startup operation, molten salts need to be pumped to flow into the pipes which may have lower temperature than the freezing point of molten salt due to the cold ambient temperature overnight or over the suspension of operation. Preventing the freezing of molten salt in cold pipes becomes a critical issue to the safe operation of a concentrating solar thermal power plant or a molten salt nuclear power plant. This study conducted a basic heat transfer analysis of the transient heat transfer from flowing molten salt to a cold pipe to determine the length from entrance to the onset of freezing of the fluid. From our modeling and analytical solution using method of characteristics, the correlation of the location of onset of freezing of molten salt with respect to the flow velocity, heat capacities of molten salt and pipes, dimension of the pipes, and the initial temperatures of salts and pipes, have been understood clearly. The modeling and computational tool can fundamentally help engineers to design a system to avoid freezing and clogging at cold startup when molten salt is applied as a heat transfer fluid.
- 26 June 2023
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 146 (1) , 1-9
Optimization of Dimensions of Smooth and Twisted-Tape-Inserted Tubes for Heat Transfer with NaCl/KCl/MgCl2 Molten Salts by Principle of Entropy Generation Minimization
The entropy generation minimization principle is used as the criterion to optimize the flow and heat transfer of solar collectors and heat exchangers that use molten salts NaCl–KCl–MgCl2 and KCl–MgCl2. The Gnielinski correlation for the Nusselt number versus Reynolds number, as well as the Moody friction factor given by Petukhov, was used for the calculation of the convective heat transfer coefficient and pressure loss due to friction in smooth tubes. For twisted-tap-inserted tube, equations of Nu and friction factor provided by Manglik and Bergles were used. The objective function, the entropy generation rate of the heat transfer system, was expressed as the function of Reynolds number, Prandtl number, heating flux, tube diameter, etc. As a result of the analysis, the optimum Reynolds number was determined and thereby to determine the optimum Nusselt number, convective heat transfer coefficient, friction factor, and tube diameter, which also allows the calculation of optimum flow velocity. The analysis was conducted in the fluid temperature range of 500–700 °C, which covers the operation temperature for supercritical CO2 power cycles in concentrated solar power (CSP) system. Optimized results from the smooth tube and twisted-tap-inserted tube are compared, which is important to the design of solar receivers for CSP systems.
- 26 June 2023
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 146 (1) , 1-9
Optimization of Dimensions of Smooth and Twisted-Tape-Inserted Tubes for Heat Transfer with NaCl/KCl/MgCl2 Molten Salts by Principle of Entropy Generation Minimization
The entropy generation minimization principle is used as the criterion to optimize the flow and heat transfer of solar collectors and heat exchangers that use molten salts NaCl–KCl–MgCl2 and KCl–MgCl2. The Gnielinski correlation for the Nusselt number versus Reynolds number, as well as the Moody friction factor given by Petukhov, was used for the calculation of the convective heat transfer coefficient and pressure loss due to friction in smooth tubes. For twisted-tap-inserted tube, equations of Nu and friction factor provided by Manglik and Bergles were used. The objective function, the entropy generation rate of the heat transfer system, was expressed as the function of Reynolds number, Prandtl number, heating flux, tube diameter, etc. As a result of the analysis, the optimum Reynolds number was determined and thereby to determine the optimum Nusselt number, convective heat transfer coefficient, friction factor, and tube diameter, which also allows the calculation of optimum flow velocity. The analysis was conducted in the fluid temperature range of 500–700 °C, which covers the operation temperature for supercritical CO2 power cycles in concentrated solar power (CSP) system. Optimized results from the smooth tube and twisted-tap-inserted tube are compared, which is important to the design of solar receivers for CSP systems.