DBDavid Bloomquist

David Bloomquist

*This is an algorithmically generated author record based on publicly available information.

David Bloomquist has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dual Tip Penetrometer—A New In Situ Approach to Identify Cemented Sand

    by Zhihong Hu, Michael C. Mcvay, David Bloomquist, David Horhota

    The dual tip penetrometer (DTP), a novel in situ test, was developed at the University of Florida (UF) to help identify cemented sands. Pairs of DTP and standard cone penetration (CPT) tests were performed at multiple Florida Department of Transportation (FDOT) project sites in Florida. These sites included the West Bay Bridge, and the Port Orange Relief Bridge. Cemented sand layers were present at different depths at these sites. Both DTP and CPT results were analyzed to screen cemented sand identifiers (tip resistance qc, friction ratio Rf, and the ratio between the second and first resistances T2/T1). The ratio T2/T1 was determined to be best identifier for identifying cemented sand. Based on the above test results and analyses, it appears that the DTP could be an efficient tool to identify cemented sand and better predict pile capacity.

  • Measured and Predicted Response of a New Jetted and Grouted Precast Pile with Membranes in Cohesionless Soils

    by Sudheesh Thiyyakkandi, Michael McVay, David Bloomquist, Peter Lai

    With increased urbanization, deep foundation (bridges, signage, walls, etc.) selection is moving toward the minimization of disturbance and installation time, as well as addressing quality control and assurance issues. Unfortunately, many types of deep foundations involve noise and vibration during installation (e.g., driven piles) or integrity and reduced resistance issues (e.g., drilled shafts, both conventional and post grouted tip, continuous flight auger piles). This paper presents a new foundation type, a jetted and grouted precast pile, which uses the advantages of several proven deep foundation installation techniques. The installation of the new pile is comprised of three distinct phases: (1) pressurized water-jetting of a precast pile into the ground; (2) side grouting of the pile; and (3) tip grouting. The pile has two separate side grouting zones, each with its own grout delivery system. Each grout zone is covered with a semirigid membrane, which results in radial expansion of the soil...


  • Evaluation of LRFD Resistance Factors and Risk for Mechanically Stabilized Earth Walls

    by S. Wasman, M. McVay, D. Bloomquist, M. Harrison, P. Lai

    The use of Mechanically Stabilized Earth (MSE) walls is very common in congested urban areas. AASHTO's current LRFD resistance values were established from Allowable Stress Design Factors of Safety. Variability of soil friction angle, unit weight, cohesion, etc. is not considered. This study investigates the influence of soil property variability on MSE wall sliding and bearing stability and compares Capacity Demand Ratio (CDR) distributions from conventional analytical approaches with laboratory centrifuge model results. Next, the probability of failures (CDR < 1.0) and associated variability is applied in risk assessment of two MSE walls used in existing transportation infrastructure subsystems. The risk assessment was used to develop recommended probability of failures in design to meet the associated cost of repair if catastrophic failures of the walls are to occur.

  • An Innovative Prefabricated Pile Installation Method Utilizing Jetting and Pressure Grouting

    by Peter Lai, Michael McVay, David Bloomquist, Heath Forbes

    The majority of Florida Department of Transportation (FDOT) highway structures (e.g., bridges, signage, etc.) are founded on deep foundations, i.e., driven piles and drilled shafts. In the past, the most commonly used foundation type was driven piles. With increased urbanization, the noise and vibrations associated with pile driving has resulted in more drilled shaft usage due to its less intrusive characteristics. Unfortunately, due to horizontal soil stress relief during installation, drilled shafts suffer reduced axial and torsional resistance when compared to similar sized driven piles. Additionally, as-built drilled shaft integrity is generally more questionable than precast piles. To address these concerns, FDOT investigated post grouted drilled shaft tips, which not only increases the end bearing, but also proof tests every shaft. However, the issues of quality control (i.e., the structural integrity of the cast-in-place shaft) and the reduction in side friction due to horizontal stress relaxation still remained. Thus, the FDOT funded a research project to develop an innovative new deep foundation type which ensures both the quality control of a precast member with the lateral stress increase similar to a driven pile but with the minimum intrusion of a drilled shaft. It is referred to as a jet-grouted precast pile or jet-grout pile. The research was conducted in FDOT's new cylindrical 3.66 by 10.67 meter in-ground geotechnical test chamber, which is capable of monitoring soil stresses and deformations. The first trials involved jetting precast concrete piles with multiple sets of embedded grout delivery pipes. The early tests revealed higher horizontal versus vertical distribution of the compaction grout, as well as poor bonding between the grout and pile. Subsequently, the grout delivery system was re-designed; a new colloidal grout mix was developed along with the introduction of grout membranes on the outside of the pile. Small scale testing showed complete envelopment of the pile with excellent grout bond to the pile. Finally, a full scale (0.406m x 0.406m x 6 m) pile was jetted and subsequently grouted along its length in two stages with no tip grouting. The pile was then torque tested to 610 kN-m with 15° of rotation, resulting in a unit torsional side resistance of 77 kPa. Next, the tip of the pile was grouted and a top down compression test yielded 1,335 kN of resistance at 0.25 mm of vertical pile head movement that exceeded the resistance of a traditional similar size driven pile.


  • Axial Pile Capacity of Large Diameter Cylinder Piles

    by Peter Lai, Michael McVay, David Bloomquist, Dhuruva Badri

    This paper reports on the behavior of large diameter cylinder piles under both driving and static conditions. Of special interest is the understanding of the tip resistance and the associated soil column within the pile under static and dynamic conditions. An analysis of driving forces, shows that inertia on the soil plug rapidly exceeds the static skin friction between the pile and soil on the inside of the cylinder. The analysis of the soil column for static conditions was undertaken with an Eulerian finite element viscous analysis, ADINA-F. The static analysis revealed that even when the cylinder "cookie cut" under driving it behaved "plugged" under static conditions for a multitude of soil strengths and wall thicknesses. Next, based on a database of 35 load tests (22 concrete & 13 steel) unit side shear and end bearing for cylinder piles as a function of pile material (i.e., steel and concrete) and insitu SPT N were developed and compared successfully to Schmertmann's original values for small diameter piles. Finally, LRFD resistance factors, φ, for the proposed cylinder pile design were determined.