Azusa Yudo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Azusa Yudo has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Shigehiro Kagaya
Department of Environmental Applied Chemistry, Faculty of Engineering, University of Toyama, Toyama, Japan
3 shared publications - Shuji Kodama
Department of Chemistry, School of Science, Tokai University, Hiratsuka, Japan
3 shared publications - Tomoko Kemmei
Toyama Institute of Health, Imizu, Japan
3 shared publications - Yoshinori Inoue
Department of Environmental Applied Chemistry, Faculty of Engineering, University of Toyama, Toyama, Japan
3 shared publications - Atsushi Yamamoto
Department of Biological Chemistry, College of Bioscience and Biotechnology, Chubu University, Kasugai, Japan
1 shared publication - Kazuichi Hayakawa
Kanazawa University
1 shared publication
Latest Publications
- 2 October 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (12) , 1883-1892
Solid-phase extraction of ethyleneamines in river water prior to their determination by high-performance liquid chromatography with ultraviolet detection
A method based on solid-phase extraction (SPE) has been developed for the preconcentration of three kinds of ethyleneamines (EAs) [ethylenediamine (EDA), diethylenetriamine (DETA), and triethylenetetramine (TETA)] in river water for their high-performance liquid chromatographic (HPLC) determination by using on-line complexation with Cu(II) ion and ultraviolet (UV) detection. EAs, which are protonated in acidic and neutral conditions, could be concentrated by using cation-exchange SPE. However, inorganic cations and humic substances, often present in river water, interfered with this preconcentration. Inorganic cations, such as Ca and Mg ions, compete with EAs in cation-exchange processes. This interference could be reduced by masking them with ethylenediaminetetraacetic acid. Humic substances, such as humic acid and fluvic acid, seem to be due to the electrostatic interaction of EAs with them in the sample solution. This interference was reduced by passing the sample solution through an anion-exchange cartridge before the cation-exchange SPE. The interacted EAs remained in the anion-exchange cartridge; they could be eluted by washing out the anion-exchange cartridge with diluted HCl. In this washing process, although fulvic acid was eluted at the same time, it could be removed by passing the eluate through a reversed-phase cartridge connected in a series. After removing these interferences, EAs could be extraced with the cation-exchange SPE and quantitatively eluted by passing Cu(II) solution through the cartridge. The proposed method of including the HPLC–UV combined with the SPE was available for the determination of EAs in river water at concentrations as low as 0.015 µM for EDA and DETA and 0.05 µM for TETA. The high recoveries (83%–103%) and repeatabilities (RSD 1.2%–4.3%) were obtained for EAs from two river water samples spiked with two different concentrations of EAs. The proposed method was applied to analyses of river water samples taken from four rivers in Toyama Prefecture, Japan. Graphical Abstract
- 2 October 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (12) , 1883-1892
Solid-phase extraction of ethyleneamines in river water prior to their determination by high-performance liquid chromatography with ultraviolet detection
A method based on solid-phase extraction (SPE) has been developed for the preconcentration of three kinds of ethyleneamines (EAs) [ethylenediamine (EDA), diethylenetriamine (DETA), and triethylenetetramine (TETA)] in river water for their high-performance liquid chromatographic (HPLC) determination by using on-line complexation with Cu(II) ion and ultraviolet (UV) detection. EAs, which are protonated in acidic and neutral conditions, could be concentrated by using cation-exchange SPE. However, inorganic cations and humic substances, often present in river water, interfered with this preconcentration. Inorganic cations, such as Ca and Mg ions, compete with EAs in cation-exchange processes. This interference could be reduced by masking them with ethylenediaminetetraacetic acid. Humic substances, such as humic acid and fluvic acid, seem to be due to the electrostatic interaction of EAs with them in the sample solution. This interference was reduced by passing the sample solution through an anion-exchange cartridge before the cation-exchange SPE. The interacted EAs remained in the anion-exchange cartridge; they could be eluted by washing out the anion-exchange cartridge with diluted HCl. In this washing process, although fulvic acid was eluted at the same time, it could be removed by passing the eluate through a reversed-phase cartridge connected in a series. After removing these interferences, EAs could be extraced with the cation-exchange SPE and quantitatively eluted by passing Cu(II) solution through the cartridge. The proposed method of including the HPLC–UV combined with the SPE was available for the determination of EAs in river water at concentrations as low as 0.015 µM for EDA and DETA and 0.05 µM for TETA. The high recoveries (83%–103%) and repeatabilities (RSD 1.2%–4.3%) were obtained for EAs from two river water samples spiked with two different concentrations of EAs. The proposed method was applied to analyses of river water samples taken from four rivers in Toyama Prefecture, Japan. Graphical Abstract
- 23 February 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (6) , 885-890
Determination of iodide in concentrated chloride springs by reversed-phase high-performance liquid chromatography with ultraviolet detection
We developed a convenient and simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method for analysis of iodide in concentrated chloride springs. Using a C18 column, the iodide and chloride peaks were well separated. Setting the wavelength at 240 nm allows direct ultraviolet (UV) detection of iodide without any UV or Schlieren effect due to the high chloride concentration. The high ionic strength of spring samples containing high levels of sodium chloride broadens the iodide peak. Iodide was quantified based on the peak areas of standard solutions of iodide, in which 100 mM sodium chloride was added to match the saline matrixes with the samples. The detection limit of iodide at a signal-to-noise ratio of 3 was 0.0003 mM. The detector response was linear over the concentration ranges of 0.001–0.1 mM. The proposed RP-HPLC/UV method was successfully applied to determine iodide in some concentrated chloride spring samples. Graphical abstract
- 23 February 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (6) , 885-890
Determination of iodide in concentrated chloride springs by reversed-phase high-performance liquid chromatography with ultraviolet detection
We developed a convenient and simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method for analysis of iodide in concentrated chloride springs. Using a C18 column, the iodide and chloride peaks were well separated. Setting the wavelength at 240 nm allows direct ultraviolet (UV) detection of iodide without any UV or Schlieren effect due to the high chloride concentration. The high ionic strength of spring samples containing high levels of sodium chloride broadens the iodide peak. Iodide was quantified based on the peak areas of standard solutions of iodide, in which 100 mM sodium chloride was added to match the saline matrixes with the samples. The detection limit of iodide at a signal-to-noise ratio of 3 was 0.0003 mM. The detector response was linear over the concentration ranges of 0.001–0.1 mM. The proposed RP-HPLC/UV method was successfully applied to determine iodide in some concentrated chloride spring samples. Graphical abstract
- 21 June 2024
- Published by Springer Nature in Chromatographia
- Vol. 87 (7-8) , 463-470
Simultaneous Determination of Ethyleneamines by Reversed-Phase Ion-Pair Chromatography with Ultraviolet Detection Using on-Line Complexation with Copper(II) Ion
- 21 June 2024
- Published by Springer Nature in Chromatographia
- Vol. 87 (7-8) , 463-470
Simultaneous Determination of Ethyleneamines by Reversed-Phase Ion-Pair Chromatography with Ultraviolet Detection Using on-Line Complexation with Copper(II) Ion