Zoe Bolton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zoe Bolton has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Layne Murphy
Nanometrology Section, National Measurement Institute Australia, 36 Bradfield Road, Lindfield, NSW 2070, Sydney, Australia
1 shared publication - Malcolm A. Lawn
National Measurement Institute of Australia (Australia)
1 shared publication - Samuel Gartner
Nanometrology Section, National Measurement Institute Australia, 36 Bradfield Road, Lindfield, NSW 2070, Sydney, Australia
1 shared publication - Victoria Anne Coleman
Nanometrology Section, National Measurement Institute Australia, Lindfield, NSW, Australia
1 shared publication - Yechan Oh
Nanometrology Section, National Measurement Institute Australia, 36 Bradfield Road, Lindfield, NSW 2070, Sydney, Australia
1 shared publication
Latest Publications
- Open Access
- 12 July 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (10) , 105018
Step height measurement of monoatomic silicon crystal lattice steps with a commercial atomic force microscope
Precise control of advanced materials relies on accurate dimensional metrology at the sub-nanometre scale. At this scale, the accuracy of scanning probe microscopy (SPM) has been limited by the lack of traceable transfer standard artefacts with calibration structures of suitable dimensions. With the adoption in 2019 of the silicon crystal lattice spacing as a secondary realization of the metre in the International System of Units (SI), SPM users have direct access to a realization of the SI metre at the sub-nanometre level by means of the step height of self-assembled monatomic lattice steps that can form on the surface of silicon crystals. A key challenge of successfully adopting this pathway is establishing protocols to minimize measurement errors and artefacts in routine laboratory use. In this study, step height measurements of monoatomic lattice steps in an ordinal/staircase structure on a Si(111) crystal surface have been derived from images acquired with a commercially available, research-level atomic force microscope (AFM). Measurement results derived from AFM images using three different SPM image processing and analysis software packages are compared. Significant sources of measurement uncertainty are identified, principally the contribution from the dependence on scan direction. The calibration of the AFM derived from this measurement was used to traceably measure the sub-nanometre lattice steps on a silicon carbide crystal surface to demonstrate the viability of this calibration pathway.
- 12 July 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (10) , 105018
Open AccessStep height measurement of monoatomic silicon crystal lattice steps with a commercial atomic force microscope
Precise control of advanced materials relies on accurate dimensional metrology at the sub-nanometre scale. At this scale, the accuracy of scanning probe microscopy (SPM) has been limited by the lack of traceable transfer standard artefacts with calibration structures of suitable dimensions. With the adoption in 2019 of the silicon crystal lattice spacing as a secondary realization of the metre in the International System of Units (SI), SPM users have direct access to a realization of the SI metre at the sub-nanometre level by means of the step height of self-assembled monatomic lattice steps that can form on the surface of silicon crystals. A key challenge of successfully adopting this pathway is establishing protocols to minimize measurement errors and artefacts in routine laboratory use. In this study, step height measurements of monoatomic lattice steps in an ordinal/staircase structure on a Si(111) crystal surface have been derived from images acquired with a commercially available, research-level atomic force microscope (AFM). Measurement results derived from AFM images using three different SPM image processing and analysis software packages are compared. Significant sources of measurement uncertainty are identified, principally the contribution from the dependence on scan direction. The calibration of the AFM derived from this measurement was used to traceably measure the sub-nanometre lattice steps on a silicon carbide crystal surface to demonstrate the viability of this calibration pathway.