Markus Wick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Markus Wick has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Anh Chu
Institute of Smart Sensors, Universität Stuttgart, 70569 Stuttgart, Germany
1 shared publication - Boris Naydenov
Helmholtz-Zentrum Berlin für Materialien und Energie
1 shared publication - Jens Anders
University of Stuttgart
1 shared publication - Joseph E. McPeak
University of Copenhagen
1 shared publication - Klaus Lips
Helmholtz-Zentrum Berlin für Materialien und Energie GmbH , Hahn-Meitner Platz 1
1 shared publication - Klaus-Peter Dinse
Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin, Germany
1 shared publication
Latest Publications
- Open Access
- 16 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (33) , eado5467
Microwave field mapping for EPR-on-a-chip experiments
Electron paramagnetic resonance–on-a-chip (EPRoC) devices use small voltage-controlled oscillators (VCOs) for both the excitation and detection of the EPR signal, allowing access to unique sample environments by lifting the restrictions imposed by resonator-based EPR techniques. EPRoC devices have been successfully used at multiple frequencies (7 to 360 gigahertz) and have demonstrated their utility in producing high-resolution spectra in a variety of spin centers. To enable quantitative measurements using EPRoC devices, the spatial distribution of the B 1 field produced by the VCOs must be known. As an example, the field distribution of a 12-coil VCO array EPRoC operating at 14 gigahertz is described in this study. The frequency modulation–recorded EPR spectra of a “point”-like and a thin-film sample were investigated while varying the position of both samples in three directions. The results were compared to COMSOL simulations of the B 1 -field intensity. The EPRoC array sensitive volume was determined to be ~19 nanoliters. Implications for possible EPR applications are discussed.
- 16 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (33) , eado5467
Open AccessMicrowave field mapping for EPR-on-a-chip experiments
Electron paramagnetic resonance–on-a-chip (EPRoC) devices use small voltage-controlled oscillators (VCOs) for both the excitation and detection of the EPR signal, allowing access to unique sample environments by lifting the restrictions imposed by resonator-based EPR techniques. EPRoC devices have been successfully used at multiple frequencies (7 to 360 gigahertz) and have demonstrated their utility in producing high-resolution spectra in a variety of spin centers. To enable quantitative measurements using EPRoC devices, the spatial distribution of the B 1 field produced by the VCOs must be known. As an example, the field distribution of a 12-coil VCO array EPRoC operating at 14 gigahertz is described in this study. The frequency modulation–recorded EPR spectra of a “point”-like and a thin-film sample were investigated while varying the position of both samples in three directions. The results were compared to COMSOL simulations of the B 1 -field intensity. The EPRoC array sensitive volume was determined to be ~19 nanoliters. Implications for possible EPR applications are discussed.