Rui Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rui Feng has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Bangcheng Han
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
7 shared publications Bangcheng Han
4 shared publications- Haifeng Zhang
School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China
3 shared publications - Ximing Liu
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
3 shared publications Bo Feng
Fu Foundation School of Engineering and Applied Science, Columbia University in the City of New York, New York, NY, USA
2 shared publications- Daiyong Chen
Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, Hangzhou, China
2 shared publications
Latest Publications
- 6 October 2026
- Published by Elsevier in Measurement
- Vol. 292
Non-invasive reconstruction of internal planar magnetic fields using optimized external sensor arrays and hybrid basis functions
- 6 October 2026
- Published by Elsevier in Measurement
- Vol. 292
Non-invasive reconstruction of internal planar magnetic fields using optimized external sensor arrays and hybrid basis functions
- 28 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
Two-Stage Nested Magnetic Field Control System Based on Time-Frequency Domain Collaboration for Magnetically Shielded Room
The complex electromagnetic disturbances often result in excessively high magnetic field noise. This article proposes a two-stage nested magnetic field control system based on time-frequency domain collaboration for a magnetically shielded room (MSR) to suppress the disturbance magnetic field and reduce magnetic field noise. The system creates a high-bandwidth external control system by placing external auxiliary coils and a fluxgate sensor outside the MSR, avoiding mutual interference with the internal control system. Subsequently, the system uses a self-tuning proportional-integral-derivative (PID) based on pole placement control and the gradient algorithm based on discrete Fourier transform to obtain the optimal internal noise level. This proposed method has effectively increased the control bandwidth while avoiding the design of complex two-stage decoupling strategies. Compared with the traditional only internal control system, the average noise suppression ability within the target frequency band has been improved by more than 20 $\mathbf{\%}$ .
- 28 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
Two-Stage Nested Magnetic Field Control System Based on Time-Frequency Domain Collaboration for Magnetically Shielded Room
The complex electromagnetic disturbances often result in excessively high magnetic field noise. This article proposes a two-stage nested magnetic field control system based on time-frequency domain collaboration for a magnetically shielded room (MSR) to suppress the disturbance magnetic field and reduce magnetic field noise. The system creates a high-bandwidth external control system by placing external auxiliary coils and a fluxgate sensor outside the MSR, avoiding mutual interference with the internal control system. Subsequently, the system uses a self-tuning proportional-integral-derivative (PID) based on pole placement control and the gradient algorithm based on discrete Fourier transform to obtain the optimal internal noise level. This proposed method has effectively increased the control bandwidth while avoiding the design of complex two-stage decoupling strategies. Compared with the traditional only internal control system, the average noise suppression ability within the target frequency band has been improved by more than 20 $\mathbf{\%}$ .
- 30 April 2026
- Published by Elsevier in Measurement
- Vol. 278
Compact power stabilization approach for amplified lasers based on a dual-loop ADRC strategy
- 30 April 2026
- Published by Elsevier in Measurement
- Vol. 278
Compact power stabilization approach for amplified lasers based on a dual-loop ADRC strategy
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
Design of Uniform-Field Coils With Adjustable Coil Constant for Calibration of Triaxial Magnetometers Across Different Magnetic Field Ranges
The calibration of a tri-axial magnetometer (TAM) relies on a high-precision reference magnetic source that provides a known magnetic field, and its accuracy directly determines the final calibration precision. To address the challenge of calibrating TAMs across widely varying measurement ranges found in diverse applications, this paper proposes a coil design method featuring an adjustable coil constant (ACC). By integrating the target field method (TFM) and the non-dominated sorting genetic algorithm II with adaptive penalties (AP-NSGA-II), the coil structure is optimized to generate controllable magnetic fields spanning multiple orders of magnitude. This design enables the generation of a highly uniform magnetic field over a large central volume without relying on current sources with multiple output ranges. Experimental results demonstrate that the maximum magnetic field non-uniformity is 0.433% across different ACC settings, aligning well with design expectations. Furthermore, by combining the proposed system with the differential evolution (DE) algorithm, TAM calibration was performed at magnetic field intensities of 30,000 nT and 100 nT, achieving post-calibration residuals of 2.32 nT and 1.97 nT, respectively. Experiments verify that the coils designed with this method can provide high-precision, uniform reference magnetic fields for calibrating different types of TAMs across wide measurement ranges.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
Design of Uniform-Field Coils With Adjustable Coil Constant for Calibration of Triaxial Magnetometers Across Different Magnetic Field Ranges
The calibration of a tri-axial magnetometer (TAM) relies on a high-precision reference magnetic source that provides a known magnetic field, and its accuracy directly determines the final calibration precision. To address the challenge of calibrating TAMs across widely varying measurement ranges found in diverse applications, this paper proposes a coil design method featuring an adjustable coil constant (ACC). By integrating the target field method (TFM) and the non-dominated sorting genetic algorithm II with adaptive penalties (AP-NSGA-II), the coil structure is optimized to generate controllable magnetic fields spanning multiple orders of magnitude. This design enables the generation of a highly uniform magnetic field over a large central volume without relying on current sources with multiple output ranges. Experimental results demonstrate that the maximum magnetic field non-uniformity is 0.433% across different ACC settings, aligning well with design expectations. Furthermore, by combining the proposed system with the differential evolution (DE) algorithm, TAM calibration was performed at magnetic field intensities of 30,000 nT and 100 nT, achieving post-calibration residuals of 2.32 nT and 1.97 nT, respectively. Experiments verify that the coils designed with this method can provide high-precision, uniform reference magnetic fields for calibrating different types of TAMs across wide measurement ranges.
- 25 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (8) , 12313-12325
Adaptive Active Disturbance Rejection Control for Suppressing Multiple Uncertain Periodic Magnetic Field Disturbances
In complex magnetic environments, accurately estimating and suppressing multiple uncertain periodic and aperiodic disturbances is critical for magnetocardiography (MCG) imaging. This article proposes an adaptive active disturbance rejection controller (ADRC) with a multiresonator and a variable-step multifrequency estimator for the active magnetic field control (AMFC) system. The core innovation is the variable-step multifrequency estimator that enables real-time, precise, and adaptive tracking of multiple disturbance frequencies. Integrated with the multiresonator extended state observer (ESO), the tracked frequencies are dynamically allocated to the corresponding resonant center frequencies, allowing simultaneous observation and suppression of both multiple periodic and aperiodic magnetic disturbances. Experimental validation within a magnetically shielded room (MSR) demonstrates that the proposed method significantly outperforms conventional fixed-step methods, achieving: 1) a 21.2% faster convergence time and a 56.3% lower frequency estimation error compared to fixed-step estimators; 2) a 73.3% higher disturbance suppression ratio; and 3) a 10.2% improvement in the signal-to-noise ratio (SNR) of MCG signals. These results highlight the superior performance of the proposed method in precise magnetic field control for MCG.
- 25 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (8) , 12313-12325
Adaptive Active Disturbance Rejection Control for Suppressing Multiple Uncertain Periodic Magnetic Field Disturbances
In complex magnetic environments, accurately estimating and suppressing multiple uncertain periodic and aperiodic disturbances is critical for magnetocardiography (MCG) imaging. This article proposes an adaptive active disturbance rejection controller (ADRC) with a multiresonator and a variable-step multifrequency estimator for the active magnetic field control (AMFC) system. The core innovation is the variable-step multifrequency estimator that enables real-time, precise, and adaptive tracking of multiple disturbance frequencies. Integrated with the multiresonator extended state observer (ESO), the tracked frequencies are dynamically allocated to the corresponding resonant center frequencies, allowing simultaneous observation and suppression of both multiple periodic and aperiodic magnetic disturbances. Experimental validation within a magnetically shielded room (MSR) demonstrates that the proposed method significantly outperforms conventional fixed-step methods, achieving: 1) a 21.2% faster convergence time and a 56.3% lower frequency estimation error compared to fixed-step estimators; 2) a 73.3% higher disturbance suppression ratio; and 3) a 10.2% improvement in the signal-to-noise ratio (SNR) of MCG signals. These results highlight the superior performance of the proposed method in precise magnetic field control for MCG.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (8) , 12464-12476
A Two-Step Cooptimization Method for Sensor Placement and Compensation Performance of MIMO Active Magnetic Shielding System
Sensor network-based multi-input multi-output (MIMO) active magnetic shielding (AMS) is an important path toward regional magnetic field control. In this article, we propose a systematic two-step collaborative optimization method based on the theoretical mechanism of the “placement-performance decoupling.” First, we demonstrate the decoupling transition characteristics between the sensor placement and control performance and validate it by using Monte Carlo (MC) simulations. Subsequently, we optimize the geometric placement to ensure structural robustness and spatial uniformity based on the phase transition theory. Finally, we use the target field method (TFM) to enable flexible regulation of the compensated magnetic field states. The “Utopian Point” is selected to optimize the representative operating point, which significantly improves the signal-to-noise ratio (SNR) by shifting sensors away from the zero-crossing singularity. The experimental results demonstrate an 8.6% deviation in condition number (CN) and a 6.4% deviation in the average residual field over a 1 $\boldsymbol{\times}$ 1 $\boldsymbol{\times}$ 1 m3 target region. Moreover, the SNR reaches a 3.5 dB improvement for quasi-static magnetic field, verifying its advantages in both shielding efficacy and signal quality.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (8) , 12464-12476
A Two-Step Cooptimization Method for Sensor Placement and Compensation Performance of MIMO Active Magnetic Shielding System
Sensor network-based multi-input multi-output (MIMO) active magnetic shielding (AMS) is an important path toward regional magnetic field control. In this article, we propose a systematic two-step collaborative optimization method based on the theoretical mechanism of the “placement-performance decoupling.” First, we demonstrate the decoupling transition characteristics between the sensor placement and control performance and validate it by using Monte Carlo (MC) simulations. Subsequently, we optimize the geometric placement to ensure structural robustness and spatial uniformity based on the phase transition theory. Finally, we use the target field method (TFM) to enable flexible regulation of the compensated magnetic field states. The “Utopian Point” is selected to optimize the representative operating point, which significantly improves the signal-to-noise ratio (SNR) by shifting sensors away from the zero-crossing singularity. The experimental results demonstrate an 8.6% deviation in condition number (CN) and a 6.4% deviation in the average residual field over a 1 $\boldsymbol{\times}$ 1 $\boldsymbol{\times}$ 1 m3 target region. Moreover, the SNR reaches a 3.5 dB improvement for quasi-static magnetic field, verifying its advantages in both shielding efficacy and signal quality.
- 17 March 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (11) , 115002
An improved Jiles–Atherton dynamic hysteresis model with dynamic parameter adjustment and loop drift correction for variable amplitude excitation
Accurate modeling for material hysteresis is fundamental to the electromagnetic simulation and the optimization of soft magnetic material applications. Although the classical Jiles–Atherton (JA) model offers clear physical significance, the predictive capability is significantly limited under complex variable amplitude excitations, due to the neglect of minor loop distortion and loop drift. To address the demand for high-precision analog solutions in engineering applications, an improved JA dynamic hysteresis model with dynamic parameter adjustment and loop drift correction is proposed in this paper. First, the pinning coefficient and the reversible magnetization coefficient are dynamically modeled as functions of the anhysteretic magnetization intensity, thereby precisely capturing domain wall interactions at different magnetization levels. The dual scaling factor is then introduced for the irreversible magnetization component to address the minor loop shift issues under small amplitude excitations. Finally, the model parameters are identified using an adaptive grid multi-objective particle swarm optimization algorithm, and validated with experimental data from permalloy under variable amplitude excitations ranging from 0.1–60 A m −1 and 1–10 Hz. Results demonstrate that the proposed model achieves an average relative error below 5.28% for remanence and coercivity, with the normalized root mean square error below 5.91% for the entire hysteresis loop, particularly improving prediction accuracy for minor loops at small amplitude. This work provides a high-fidelity simulation tool for modeling the magnetization behavior of materials and magnetic devices under variable-amplitude excitation.
- 17 March 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (11) , 115002
An improved Jiles–Atherton dynamic hysteresis model with dynamic parameter adjustment and loop drift correction for variable amplitude excitation
Accurate modeling for material hysteresis is fundamental to the electromagnetic simulation and the optimization of soft magnetic material applications. Although the classical Jiles–Atherton (JA) model offers clear physical significance, the predictive capability is significantly limited under complex variable amplitude excitations, due to the neglect of minor loop distortion and loop drift. To address the demand for high-precision analog solutions in engineering applications, an improved JA dynamic hysteresis model with dynamic parameter adjustment and loop drift correction is proposed in this paper. First, the pinning coefficient and the reversible magnetization coefficient are dynamically modeled as functions of the anhysteretic magnetization intensity, thereby precisely capturing domain wall interactions at different magnetization levels. The dual scaling factor is then introduced for the irreversible magnetization component to address the minor loop shift issues under small amplitude excitations. Finally, the model parameters are identified using an adaptive grid multi-objective particle swarm optimization algorithm, and validated with experimental data from permalloy under variable amplitude excitations ranging from 0.1–60 A m −1 and 1–10 Hz. Results demonstrate that the proposed model achieves an average relative error below 5.28% for remanence and coercivity, with the normalized root mean square error below 5.91% for the entire hysteresis loop, particularly improving prediction accuracy for minor loops at small amplitude. This work provides a high-fidelity simulation tool for modeling the magnetization behavior of materials and magnetic devices under variable-amplitude excitation.
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 2956-2968
Physics-Informed Neural Network for Cross-Domain Predictive Control of Tapered Amplifier Thermal Stabilization
Thermally induced laser noise critically limits the sensitivity of quantum sensor arrays using ultra-stable amplified lasers, stemming from nonlinear gain-temperature coupling in tapered amplifiers (TAs). Existing temperature control approaches exhibit limited performance across varying laser power regimes, resulting in either measurement sensitivity degradation or demanding recalibration procedures in quantum precision measurements. This work presents an innovative architecture integrating a specialized physics-informed gated recurrent unit (PI-GRU) network with a model predictive control (MPC) strategy, achieving high stability of TA temperature across multi-power laser operations. By embedding physical soft constraints, we establish a predictive model with enhanced physical consistency that enables reliable extrapolation capability beyond trained operational scenarios. Based on the model’s accurate multi-step predictions, a hierarchical parallel MPC architecture is constructed to achieve real-time compensation of thermal instability. While trained exclusively on safe low-power samples, the proposed PI-GRU MPC demonstrates significant improvements at high-power operations, achieving an over 58.2% greater prediction accuracy and an over 50.0% better temperature stability compared to data-driven methods, as experimentally validated. The synchronization of physics-informed neural networks with MPC frameworks offers a novel solution to robustness challenges in cross-domain control under varying operating regimes.
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 2956-2968
Physics-Informed Neural Network for Cross-Domain Predictive Control of Tapered Amplifier Thermal Stabilization
Thermally induced laser noise critically limits the sensitivity of quantum sensor arrays using ultra-stable amplified lasers, stemming from nonlinear gain-temperature coupling in tapered amplifiers (TAs). Existing temperature control approaches exhibit limited performance across varying laser power regimes, resulting in either measurement sensitivity degradation or demanding recalibration procedures in quantum precision measurements. This work presents an innovative architecture integrating a specialized physics-informed gated recurrent unit (PI-GRU) network with a model predictive control (MPC) strategy, achieving high stability of TA temperature across multi-power laser operations. By embedding physical soft constraints, we establish a predictive model with enhanced physical consistency that enables reliable extrapolation capability beyond trained operational scenarios. Based on the model’s accurate multi-step predictions, a hierarchical parallel MPC architecture is constructed to achieve real-time compensation of thermal instability. While trained exclusively on safe low-power samples, the proposed PI-GRU MPC demonstrates significant improvements at high-power operations, achieving an over 58.2% greater prediction accuracy and an over 50.0% better temperature stability compared to data-driven methods, as experimentally validated. The synchronization of physics-informed neural networks with MPC frameworks offers a novel solution to robustness challenges in cross-domain control under varying operating regimes.