MAMatthew Abulail

Matthew Abulail

*This is an algorithmically generated author record based on publicly available information.

Matthew Abulail has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Assessment of ammonia chemical kinetics using NH2 time histories in NH3 and N2O mixtures

    by Matthew Abulail, Matthew G. Sandberg, Olivier Mathieu, Eric L. Petersen

  • An improved endwall-injection technique for examining high-temperature ignition of lubricating oils in shock tubes

    by Matthew Abulail, Sean P. Cooper, Darryl J. Mohr, Eric L. Petersen

    Ignition of the lubricating fluid in a mechanical system is a highly undesirable and unsafe condition that can arise from the elevated temperatures and pressures to which the lubricant is subjected. It is therefore important to understand the fundamental chemistry behind its ignition to predict and prevent this condition. Lubricating oils, particularly those with a mineral oil base, are very complex mixtures of thousands of hydrocarbons. Additionally, these oils have very low vapor pressures and high viscosities. These physical characteristics present considerable barriers to examining and understanding lubricant ignition chemistry. Therefore, a novel experimental design was devised to create and introduce a lubricant aerosol into a shock-tube facility in a reliable yet relatively simple manner. In this way, the lubricant can be quasi-homogeneously introduced into the shock tube where it will be vaporized by the incident shock wave, and combustion can be observed behind the reflected shock wave. To characterize the technique and anchor it with previously established methods, n-hexadecane was chosen to be tested both with the endwall injection and the well-established, heated shock tube techniques. This comparison showed good agreement, proving the ability of the simple technique to produce reliable ignition delay time (IDT) results. From here, Jet-A was also tested with the current injection technique and compared to a previous generation of the technique to highlight the advantages of the present method. Then, IDT results for mineral oil were collected to establish a baseline IDT set to which off-the-shelf lubricants and additional mixtures can be compared. Finally, IDTs for the off-the-shelf, mineral-based lubricant Mobil DTE 732 were obtained and compared to the baseline as well as the n-hexadecane results. All experiments were conducted near atmospheric pressure and for temperatures between 1084 and 1530 K. An analysis of the system estimated the effective stoichiometry to be around ϕ = 1.15. Although no kinetics mechanisms exist for lubrication oils, preliminary model predictions made by modern chemical kinetics mechanisms for an alkane with 16 carbon atoms were then compared to the results to elucidate some of the chemistry this new method will allow the community to probe. This paper establishes the new method as a viable way to study and compare the ignition behavior of lubricating oils and other very low-vapor-pressure fuels in a shock tube.


  • Ignition of Aged Lubricants in a Shock Tube

    by Matthew Abulail, Raquel Juárez, Eric L. Petersen

    Lubricants experience harsh conditions which result in degradation of the oil. To imitate similar conditions, Mobil DTE 732, a common gas turbine lubricating oil, was subjected to high temperatures for an extended period of time, until thermal degradation occurred, indicated through the creation of coke. Samples were taken throughout this process, with the sample that was tested having been exposed for 78 h. Utilizing an endwall injector system, the samples were ignited behind reflected shock waves in the high-pressure shock tube (HPST) at Texas A&M University. The injector system utilizes the incident wave to increase the temperature of the lubricant past its vaporization temperature, thereby vaporizing the fuel prior to the arrival of the reflected shock. Using this system, the base Mobil DTE 732 and the 78-h sample produced from the coking test were tested at 1.06–1.58 atm and between 1171 and 1373 K. The ignition delay times (IDTs) of the samples were recorded utilizing pressure rise and hydroxyl chemiluminescence located in the sidewall of the shock tube. Upon the analysis of the results, there were negligible changes in the ignition behavior of the fuel, based on ignition delay time. However, changes in the combustion behavior were experienced, such as an absence of two-stage ignition and lower viscosity for the post-coke sample.


  • Evaluation of high-pressure syngas ignition under high-CO2 dilution in shock tubes

    by Matthew Abulail, Matthew Intardonato, Matthew Hay, Sean P. Cooper, Olivier Mathieu, Waruna D. Kulatilaka, Eric L. Petersen

  • Ignition of Various Lubricating Oil Compositions Using a Shock Tube

    by Matthew Abulail, Sean P. Cooper, Matthew G. Sandberg, Eric L. Petersen

    With new restrictions imposed on gas turbine efficiencies and power outputs, lubricating oils are used at higher temperatures and harsher conditions leading to potential, unintended combustion. To establish an understanding of lubricating oil's resistance to combustion, a new spray injector system was utilized in the High-Pressure Shock Tube (HPST) Facility at the TEES Turbomachinery Laboratory at Texas A&M University. Two gas turbine oils (Mobil DTE 732 and Castrol Perfecto X32), a base mineral oil, and a surrogate (n-hexadecane) were tested at postreflected shock conditions at equivalence ratios near 2.5. Castrol Perfecto X32 was also characterized at an equivalence ratio near 1.2. All of the lubricating oils displayed ignition between temperatures of 1152 and 1383 K and near atmospheric pressures. To characterize combustion, two different definitions of ignition delay time (IDT) were considered: sidewall OH* chemiluminescence and sidewall pressure. Both definitions were used to create temperature-dependent correlations for each of the lubricating oils. In general, both definitions provided similar results within the accuracy of the measurements. One trend from the data herein is that the brand-name oils (Mobil DTE 732 and Castrol Perfecto X32) provided ignition delay times that were similar to each other but slightly larger than the corresponding mineral oil and n-hexadecane results. This difference could be attributed to the additives that are present in the brand-name oils.


  • Ignition of Various Lubricating Oil Compositions Using a Shock Tube

    by Matthew Abulail, Sean P. Cooper, Matthew G. Sandberg, Eric L. Petersen

    With new restrictions imposed on gas turbine efficiencies and power outputs, lubricating oils are used at higher temperatures and harsher conditions leading to potential, unintended combustion. To establish an understanding of a lubricating oil’s resistance to combustion, a new spray injector system was utilized in the High-Pressure Shock Tube Facility at the TEES Turbomachinery Laboratory at Texas A&M University. Two gas turbine oils (Mobil DTE 732 and Castrol Perfecto X32), a base mineral oil, and a surrogate (n-hexadecane) were tested at post-reflected-shock conditions at equivalence ratios near 2.5. Castrol Perfecto X32 was also characterized at an equivalence ratio near 1.2. All of the lubricating oils displayed ignition between temperatures of 1152 and 1383 K and near atmospheric pressures. To characterize combustion, two different definitions of ignition delay time were considered: sidewall OH* chemiluminescence and sidewall pressure. Both definitions were used to create temperature-dependent correlations for each of the lubricating oils. In general, both definitions provided similar results within the accuracy of the measurements. One trend from the data herein is that the brand-name oils (Mobil DTE 732 and Castrol Perfecto X32) provided ignition delay times that were similar to each other but slightly larger than the corresponding mineral oil and n-hexadecane results. This difference could be attributed to the additives that are present in the brand-name oils.