Wooram Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wooram Kim has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Jung-Hyung Kim
Korea Research Institute of Standards and Science 1 , Daejeon 34113
6 shared publications - Hee-Jung Yeom
Institute of Plasma Technology, Korea Institute of Fusion Energy 5 , Gunsan 54011
5 shared publications - Hyo-Chang Lee
Department of Semiconductor Science, Engineering and Technology, Korea Aerospace University 1 , Goyang 10540
5 shared publications - Min Young Yoon
Aerospace and Aviation Electronics Research Center, Korea Aerospace University, Goyang 10540, Republic of Korea
4 shared publications - Do-Yeon Hwang
Semiconductor and Display Metrology Group, Korea Research Institute of Standards and Science (KRISS) 1 , Daejeon 34113
3 shared publications - Eun-Seok Choe
Korea Research Institute of Standards and Science, Daejeon, Republic of Korea
3 shared publications
Latest Publications
- 14 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 9521109
Development of a Wafer-Embeddable Microwave Patch Antenna Sensor for Plasma Diagnostics in Semiconductor Processing
In this study, we present a microstrip-based microwave patch antenna sensor (MPAS) that can be embedded into a wafer to measure plasma on the wafer without bulky coaxial architectures. Modern high-volume manufacturing reactors employ narrow electrode–wafer gaps, and electrode-embedded diagnostics typically require redesign of electrodes that are already densely integrated with electrostatic clamping hardware, helium backside-gas delivery paths, and lift-pin through-holes. Conventional coaxial sensors further demand control of dielectric thickness, which complicates implementation in a wafer-thickness form factor. To address these constraints, the MPAS is implemented as a sub-mm flat antenna–dielectric–ground stack compatible with direct wafer integration while enabling cutoff-method-based measurement of the absolute electron density. We validate the effective sensing region on the wafer plane using electromagnetic simulations incorporating an intentionally nonuniform plasma model. Experiments show that the MPAS measures the electron density at the plasma−sheath boundary under the investigated conditions. Finally, an array-type MPAS is demonstrated to assess within-wafer uniformity, and spatially resolved electron-density distributions are compared with etch-rate trends. These results indicate that the MPAS is a promising diagnostic platform for wafer-level plasma monitoring and provides an effective foundation for developing next-generation plasma diagnostic tools.
- 14 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 9521109
Development of a Wafer-Embeddable Microwave Patch Antenna Sensor for Plasma Diagnostics in Semiconductor Processing
In this study, we present a microstrip-based microwave patch antenna sensor (MPAS) that can be embedded into a wafer to measure plasma on the wafer without bulky coaxial architectures. Modern high-volume manufacturing reactors employ narrow electrode–wafer gaps, and electrode-embedded diagnostics typically require redesign of electrodes that are already densely integrated with electrostatic clamping hardware, helium backside-gas delivery paths, and lift-pin through-holes. Conventional coaxial sensors further demand control of dielectric thickness, which complicates implementation in a wafer-thickness form factor. To address these constraints, the MPAS is implemented as a sub-mm flat antenna–dielectric–ground stack compatible with direct wafer integration while enabling cutoff-method-based measurement of the absolute electron density. We validate the effective sensing region on the wafer plane using electromagnetic simulations incorporating an intentionally nonuniform plasma model. Experiments show that the MPAS measures the electron density at the plasma−sheath boundary under the investigated conditions. Finally, an array-type MPAS is demonstrated to assess within-wafer uniformity, and spatially resolved electron-density distributions are compared with etch-rate trends. These results indicate that the MPAS is a promising diagnostic platform for wafer-level plasma monitoring and provides an effective foundation for developing next-generation plasma diagnostic tools.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 169767-169788
Phase Unwrapping for Commercial ToF Cameras Using Single-Frequency Single-Depth Images via Dual-Attention U-Net++ Regression
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 169767-169788
Open AccessPhase Unwrapping for Commercial ToF Cameras Using Single-Frequency Single-Depth Images via Dual-Attention U-Net++ Regression
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 160586-160609
Comparative Study of AI Models for Wafer Map Defect Pattern Classification Using a Novel Pseudo-Labeling-Based Integrated Dataset
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 160586-160609
Open AccessComparative Study of AI Models for Wafer Map Defect Pattern Classification Using a Novel Pseudo-Labeling-Based Integrated Dataset
- 1 January 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 44 (1)
Tabletop extreme ultraviolet test platform for optical property evaluation of lithography materials
Extreme ultraviolet (EUV) lithography, owing to its ultrashort wavelength and high photon energy, serves as a key technology in advanced semiconductor manufacturing. As its applications continue to expand, the evaluation of essential materials—such as photoresists, pellicles, and filters—has become increasingly important to ensure process reliability and performance. With growing demand for EUV material characterization, the need for accessible and versatile testing systems has become evident. In response, this study presents the development and validation of a tabletop EUV platform designed for the evaluation of material properties, including sensitivity and transmittance. To verify the platform’s performance, two demonstration experiments were conducted. First, the transmittances of Zr foils were measured, yielding values of 43.5% for plain Zr foils and 34.7% for Ni-meshed Zr foils. Second, a lithographic patterning experiment was performed in which a line-and-space (L/S) pattern was transferred onto a photoresist using EUV exposure through a transparent mask. Successful pattern transfer was confirmed through analysis using field-emission scanning electron microscopy and atomic force microscopy. This system enables efficient and reliable evaluation of EUV materials, supporting both lithographic and optical performance assessments. It is expected to serve as a practical tool for advancing research and development of EUV-compatible materials.
- 1 January 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 44 (1)
Tabletop extreme ultraviolet test platform for optical property evaluation of lithography materials
Extreme ultraviolet (EUV) lithography, owing to its ultrashort wavelength and high photon energy, serves as a key technology in advanced semiconductor manufacturing. As its applications continue to expand, the evaluation of essential materials—such as photoresists, pellicles, and filters—has become increasingly important to ensure process reliability and performance. With growing demand for EUV material characterization, the need for accessible and versatile testing systems has become evident. In response, this study presents the development and validation of a tabletop EUV platform designed for the evaluation of material properties, including sensitivity and transmittance. To verify the platform’s performance, two demonstration experiments were conducted. First, the transmittances of Zr foils were measured, yielding values of 43.5% for plain Zr foils and 34.7% for Ni-meshed Zr foils. Second, a lithographic patterning experiment was performed in which a line-and-space (L/S) pattern was transferred onto a photoresist using EUV exposure through a transparent mask. Successful pattern transfer was confirmed through analysis using field-emission scanning electron microscopy and atomic force microscopy. This system enables efficient and reliable evaluation of EUV materials, supporting both lithographic and optical performance assessments. It is expected to serve as a practical tool for advancing research and development of EUV-compatible materials.
- 1 December 2025
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 34 (12) , 125010
Measurement of sheath width on the surface using flat-cutoff probe
This study investigates a method for measuring sheath width on electrode surfaces using a flat-cutoff probe. We performed electromagnetic (EM) wave simulations to analyze the characteristics of the plasma transmission spectrum as a function of sheath width. The simulations revealed that the maximum transmission frequency is significantly influenced by sheath width. Also, we then propose a method to measure sheath width based on a circuit model of the flat-cutoff probe, correlating the calculated transmission spectra to sheath width. Based on these simulations, we proposed a method for measuring sheath width using a flat-cutoff probe, which utilizes the calculated transmission spectra from a circuit model. We compared this method with the EM wave simulation results, and the average difference between the sheath width input in the simulation and the sheath width obtained through our proposed method was found to be 5.18%. Furthermore, we experimentally validated this method and compared the results with single Langmuir probe measurements. The findings of this study hold significant promise for enhancing various industrial plasma processing processes and advancing plasma diagnostic technology.
- 1 December 2025
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 34 (12) , 125010
Measurement of sheath width on the surface using flat-cutoff probe
This study investigates a method for measuring sheath width on electrode surfaces using a flat-cutoff probe. We performed electromagnetic (EM) wave simulations to analyze the characteristics of the plasma transmission spectrum as a function of sheath width. The simulations revealed that the maximum transmission frequency is significantly influenced by sheath width. Also, we then propose a method to measure sheath width based on a circuit model of the flat-cutoff probe, correlating the calculated transmission spectra to sheath width. Based on these simulations, we proposed a method for measuring sheath width using a flat-cutoff probe, which utilizes the calculated transmission spectra from a circuit model. We compared this method with the EM wave simulation results, and the average difference between the sheath width input in the simulation and the sheath width obtained through our proposed method was found to be 5.18%. Furthermore, we experimentally validated this method and compared the results with single Langmuir probe measurements. The findings of this study hold significant promise for enhancing various industrial plasma processing processes and advancing plasma diagnostic technology.
- Open Access
- 30 March 2025
- Published by The Korean Vacuum Society in Applied Science and Convergence Technology
- Vol. 34 (2) , 75-79
Parametric Analysis of Substrate Heating in Low-Pressure Inductively Coupled Plasma
Jin-Hoo Seong, Hee-Jung Yeom, Min Young Yoon, Do-Yeon Hwang, Hye-Jin Ju, Wooram Kim, Hyo-Chang Lee, and Jung-Hyung Kim. Applied Science and Convergence Technology 2025;34:75-9. https://doi.org/10.5757/ASCT.2025.34.2.75
- 30 March 2025
- Published by The Korean Vacuum Society in Applied Science and Convergence Technology
- Vol. 34 (2) , 75-79
Open AccessParametric Analysis of Substrate Heating in Low-Pressure Inductively Coupled Plasma
Jin-Hoo Seong, Hee-Jung Yeom, Min Young Yoon, Do-Yeon Hwang, Hye-Jin Ju, Wooram Kim, Hyo-Chang Lee, and Jung-Hyung Kim. Applied Science and Convergence Technology 2025;34:75-9. https://doi.org/10.5757/ASCT.2025.34.2.75
- Open Access
- 1 September 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (9)
Effect of radiofrequency bias power on transmission spectrum of flat-cutoff sensor in inductively coupled plasma
Real-time monitoring of plasma parameters at the wafer plane is important because it significantly affects the processing results, yield enhancement, and device integrity of plasma processing. Various plasma diagnostic sensors, including those embedded in a chamber wall and on-wafer sensors, such as flat-cutoff sensors, have been developed for plasma measurements. However, to measure the plasma density on the wafer surface in real-time when processing plasma with bias power, such as in the semiconductor etching process, one must analyze the transmission spectrum of the flat-cutoff sensor in an environment with bias power applied. In this study, the transmission-spectrum and measured plasma-density characteristics of an electrode-embedded flat-cutoff sensor are analyzed via electromagnetic simulations and experiments under applied bias power. Our findings indicate that the flat-cutoff sensor accurately measures the plasma density, which is equivalent to the input plasma density under low bias power. Conversely, under high bias power, the plasma density measured by the sensor is lower than the input plasma density. Also, a thick-sheath layer is formed owing to the high bias power, which may complicate the measurement of plasma parameters using the flat-cutoff sensor. Plasma diagnostics using a flat-cutoff sensor in thick-sheath environments can be achieved by optimizing the flat-cutoff sensor structure. Our findings can enhance the analysis of plasma parameters on-wafer surfaces in processing environments with bias power applied.
- 1 September 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (9)
Open AccessEffect of radiofrequency bias power on transmission spectrum of flat-cutoff sensor in inductively coupled plasma
Real-time monitoring of plasma parameters at the wafer plane is important because it significantly affects the processing results, yield enhancement, and device integrity of plasma processing. Various plasma diagnostic sensors, including those embedded in a chamber wall and on-wafer sensors, such as flat-cutoff sensors, have been developed for plasma measurements. However, to measure the plasma density on the wafer surface in real-time when processing plasma with bias power, such as in the semiconductor etching process, one must analyze the transmission spectrum of the flat-cutoff sensor in an environment with bias power applied. In this study, the transmission-spectrum and measured plasma-density characteristics of an electrode-embedded flat-cutoff sensor are analyzed via electromagnetic simulations and experiments under applied bias power. Our findings indicate that the flat-cutoff sensor accurately measures the plasma density, which is equivalent to the input plasma density under low bias power. Conversely, under high bias power, the plasma density measured by the sensor is lower than the input plasma density. Also, a thick-sheath layer is formed owing to the high bias power, which may complicate the measurement of plasma parameters using the flat-cutoff sensor. Plasma diagnostics using a flat-cutoff sensor in thick-sheath environments can be achieved by optimizing the flat-cutoff sensor structure. Our findings can enhance the analysis of plasma parameters on-wafer surfaces in processing environments with bias power applied.
- 11 March 2022
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 61 (06) , 061412-13
Fast and precise laser beam scanning by nonperiodic grating on a binary micromirror array
We report a precise and stable laser beam positioning method with a high scanning speed by a pixelated binary grating (PBG) realized by a compact on-off state digital micromirror device (DMD). The overall procedure for PBG pattern generation is proposed, analyzed, and experimentally verified. The resulting performances correspond to an angular resolution of 0.01 deg and angular repeatability of ± 2.54 × 10 − 4 deg over a beam steering range of ± 7.5 deg. The scanning speed of 40 deg/s is achieved in continuous scanning with a resolution of 0.01 deg. Arbitrary positions can be targeted in the scanning range with DMD’s frame rate of 4000 Hz. To verify its applicability in precision metrology, absolute distances to multiple off-axial targets were determined in parallel with a high speed. This method will open a wider application of DMD in precision LIDARs, three-dimensional calibration of precision machines, and high-resolution laser patterning.
- 11 March 2022
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 61 (06) , 061412-13
Fast and precise laser beam scanning by nonperiodic grating on a binary micromirror array
We report a precise and stable laser beam positioning method with a high scanning speed by a pixelated binary grating (PBG) realized by a compact on-off state digital micromirror device (DMD). The overall procedure for PBG pattern generation is proposed, analyzed, and experimentally verified. The resulting performances correspond to an angular resolution of 0.01 deg and angular repeatability of ± 2.54 × 10 − 4 deg over a beam steering range of ± 7.5 deg. The scanning speed of 40 deg/s is achieved in continuous scanning with a resolution of 0.01 deg. Arbitrary positions can be targeted in the scanning range with DMD’s frame rate of 4000 Hz. To verify its applicability in precision metrology, absolute distances to multiple off-axial targets were determined in parallel with a high speed. This method will open a wider application of DMD in precision LIDARs, three-dimensional calibration of precision machines, and high-resolution laser patterning.