Effect of radiofrequency bias power on transmission spectrum of flat-cutoff sensor in inductively coupled plasma
Open Access
- 1 September 2024
- journal article
- research article
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (9)
Abstract
Real-time monitoring of plasma parameters at the wafer plane is important because it significantly affects the processing results, yield enhancement, and device integrity of plasma processing. Various plasma diagnostic sensors, including those embedded in a chamber wall and on-wafer sensors, such as flat-cutoff sensors, have been developed for plasma measurements. However, to measure the plasma density on the wafer surface in real-time when processing plasma with bias power, such as in the semiconductor etching process, one must analyze the transmission spectrum of the flat-cutoff sensor in an environment with bias power applied. In this study, the transmission-spectrum and measured plasma-density characteristics of an electrode-embedded flat-cutoff sensor are analyzed via electromagnetic simulations and experiments under applied bias power. Our findings indicate that the flat-cutoff sensor accurately measures the plasma density, which is equivalent to the input plasma density under low bias power. Conversely, under high bias power, the plasma density measured by the sensor is lower than the input plasma density. Also, a thick-sheath layer is formed owing to the high bias power, which may complicate the measurement of plasma parameters using the flat-cutoff sensor. Plasma diagnostics using a flat-cutoff sensor in thick-sheath environments can be achieved by optimizing the flat-cutoff sensor structure. Our findings can enhance the analysis of plasma parameters on-wafer surfaces in processing environments with bias power applied.Keywords
Funding Information
- National Research Foundation of Korea (2020M3H4A3106004)
- National Research Council of Science and Technology (CRC-20-01-NFRI)
- Korea Evaluation Institute of Industrial Technology (1415181740)
- Korea Research Institute of Standards and Science (KRISS GP2024-0012-04)
- Ministry of Trade, Industry and Energy (1415187722)
- Ministry of Trade, Industry and Energy (RS-2023-00237058)
- Ministry of Trade, Industry and Energy (1415187709)
- Ministry of Trade, Industry and Energy (1415188153)
- Korea Semiconductor Research Consortium (00235950)
- Korea Semiconductor Research Consortium (00237058)
This publication has 41 references indexed in Scilit:
- Effect of impurities in vacuum vessels on the plasma parameters in inductive dischargesVacuum, 2023
- Plasma etching of the trench pattern with high aspect ratio mask under ion tiltingApplied Surface Science, 2022
- An analysis on transmission microwave frequency spectrum of cut-off probeApplied Physics Letters, 2011
- Effects of RF bias power on electron energy distribution function and plasma uniformity in inductively coupled argon plasmaThin Solid Films, 2011
- Effects of rf-bias power on plasma parameters in a low gas pressure inductively coupled plasmaApplied Physics Letters, 2010
- The multipole resonance probe: A concept for simultaneous determination of plasma density, electron temperature, and collision rate in low-pressure plasmasApplied Physics Letters, 2008
- Measurement of absolute electron density with a plasma impedance probeReview of Scientific Instruments, 2005
- Wave cutoff method to measure absolute electron density in cold plasmaReview of Scientific Instruments, 2004
- The hairpin resonator: A plasma density measuring technique revisitedJournal of Applied Physics, 2004
- Plasma frequency measurements for absolute plasma density by means of wave cutoff methodApplied Physics Letters, 2003