Jun-Hyung Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jun-Hyung Park has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chan-Woo Park
School of Electronics and Information Engineering, Korea Aerospace University 3 , Goyang 10540
1 shared publication - Gwang-Seok Chae
Department of Semiconductor Science, Engineering and Technology, Korea Aerospace University 1 , Goyang 10540
1 shared publication - Hee-Jung Yeom
Institute of Plasma Technology, Korea Institute of Fusion Energy 5 , Gunsan 54011
1 shared publication - Hyo-Chang Lee
Department of Semiconductor Science, Engineering and Technology, Korea Aerospace University 1 , Goyang 10540
1 shared publication - Jae-Heon Lee
Department of Semiconductor Science, Engineering and Technology, Korea Aerospace University 1 , Goyang 10540
1 shared publication - Jung-Hyung Kim
Korea Research Institute of Standards and Science 1 , Daejeon 34113
1 shared publication
Latest Publications
- Open Access
- 1 September 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (9)
Effect of radiofrequency bias power on transmission spectrum of flat-cutoff sensor in inductively coupled plasma
Real-time monitoring of plasma parameters at the wafer plane is important because it significantly affects the processing results, yield enhancement, and device integrity of plasma processing. Various plasma diagnostic sensors, including those embedded in a chamber wall and on-wafer sensors, such as flat-cutoff sensors, have been developed for plasma measurements. However, to measure the plasma density on the wafer surface in real-time when processing plasma with bias power, such as in the semiconductor etching process, one must analyze the transmission spectrum of the flat-cutoff sensor in an environment with bias power applied. In this study, the transmission-spectrum and measured plasma-density characteristics of an electrode-embedded flat-cutoff sensor are analyzed via electromagnetic simulations and experiments under applied bias power. Our findings indicate that the flat-cutoff sensor accurately measures the plasma density, which is equivalent to the input plasma density under low bias power. Conversely, under high bias power, the plasma density measured by the sensor is lower than the input plasma density. Also, a thick-sheath layer is formed owing to the high bias power, which may complicate the measurement of plasma parameters using the flat-cutoff sensor. Plasma diagnostics using a flat-cutoff sensor in thick-sheath environments can be achieved by optimizing the flat-cutoff sensor structure. Our findings can enhance the analysis of plasma parameters on-wafer surfaces in processing environments with bias power applied.
- 1 September 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (9)
Open AccessEffect of radiofrequency bias power on transmission spectrum of flat-cutoff sensor in inductively coupled plasma
Real-time monitoring of plasma parameters at the wafer plane is important because it significantly affects the processing results, yield enhancement, and device integrity of plasma processing. Various plasma diagnostic sensors, including those embedded in a chamber wall and on-wafer sensors, such as flat-cutoff sensors, have been developed for plasma measurements. However, to measure the plasma density on the wafer surface in real-time when processing plasma with bias power, such as in the semiconductor etching process, one must analyze the transmission spectrum of the flat-cutoff sensor in an environment with bias power applied. In this study, the transmission-spectrum and measured plasma-density characteristics of an electrode-embedded flat-cutoff sensor are analyzed via electromagnetic simulations and experiments under applied bias power. Our findings indicate that the flat-cutoff sensor accurately measures the plasma density, which is equivalent to the input plasma density under low bias power. Conversely, under high bias power, the plasma density measured by the sensor is lower than the input plasma density. Also, a thick-sheath layer is formed owing to the high bias power, which may complicate the measurement of plasma parameters using the flat-cutoff sensor. Plasma diagnostics using a flat-cutoff sensor in thick-sheath environments can be achieved by optimizing the flat-cutoff sensor structure. Our findings can enhance the analysis of plasma parameters on-wafer surfaces in processing environments with bias power applied.