Zekai Lai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zekai Lai has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Haibao Mu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
7 shared publications - Guanjun Zhang
Xi’an Jiaotong University
4 shared publications - Tong Bai
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
3 shared publications Haofan Lin
State Grid Zhejiang Electric Power Research Institute, Hangzhou, Zhejiang, China
2 shared publications- Maoqun Shen
School of Electrical Engineering and the State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications - Xiaochang Hua
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications
Latest Publications
- Open Access
- 27 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (17) , 3860
Field-Measurement-Based Wideband Modeling and System-Level Simulation of MMC-HVDC Converter Stations for High-Frequency Disturbance Studies
This study establishes a field-measurement-based wideband modeling and station-level simulation framework for conducted high-frequency (HF) disturbance studies in modular multilevel converter-based high-voltage direct-current (MMC-HVDC) stations. Full-scale engineering-site frequency-response measurements are used to identify kHz-to-MHz terminal models of the arm reactor and the valve-side winding of the converter transformer. The arm reactor is fitted in the admittance domain by vector fitting and synthesized as a passive parallel network containing the main inductive path and multiple damped resistor–inductor–capacitor (RLC) branches. The transformer valve-side winding is represented by a Foster I/II hybrid -type terminal network reconstructed from two single-phase port-impedance measurements. The validated equipment models are integrated into a representative Power Systems Computer-Aided Design (PSCAD) station model. A 2 ms valve-side source sequence, constructed from nearest-level-control switching instants and a parameterized switching-transient template, is applied in paired injection and zero-injection simulations. For the representative event, the source peak is 605.6 V. Over the first 4 s, the arm-reactor terminal reaches 972.6 V, while the direct-current (DC)-side, valve-side alternating-current (AC), and point-of-common-coupling (PCC) responses reach 534.2, 438.4, and 151.9 V, respectively. The corresponding peak changes relative to the source are , , , and dB. The DC-side response contains a dominant damped oscillation near 0.61 MHz, and the AC/PCC transfer varies markedly across 0.2–2.0 MHz. In a separate control-identical comparison over the first 2.5 s, the field-identified and lumped models give DC-side peaks of 171.9 and 1.23 V and PCC peaks of 121.4 and 3.93 V under the same excitation. The framework connects field-identified equipment terminal behavior with station-level time-domain propagation analysis and provides a modeling basis for broadband resonance screening and conducted electromagnetic-interference (EMI) assessment.- 27 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (17) , 3860
Open AccessField-Measurement-Based Wideband Modeling and System-Level Simulation of MMC-HVDC Converter Stations for High-Frequency Disturbance Studies
This study establishes a field-measurement-based wideband modeling and station-level simulation framework for conducted high-frequency (HF) disturbance studies in modular multilevel converter-based high-voltage direct-current (MMC-HVDC) stations. Full-scale engineering-site frequency-response measurements are used to identify kHz-to-MHz terminal models of the arm reactor and the valve-side winding of the converter transformer. The arm reactor is fitted in the admittance domain by vector fitting and synthesized as a passive parallel network containing the main inductive path and multiple damped resistor–inductor–capacitor (RLC) branches. The transformer valve-side winding is represented by a Foster I/II hybrid -type terminal network reconstructed from two single-phase port-impedance measurements. The validated equipment models are integrated into a representative Power Systems Computer-Aided Design (PSCAD) station model. A 2 ms valve-side source sequence, constructed from nearest-level-control switching instants and a parameterized switching-transient template, is applied in paired injection and zero-injection simulations. For the representative event, the source peak is 605.6 V. Over the first 4 s, the arm-reactor terminal reaches 972.6 V, while the direct-current (DC)-side, valve-side alternating-current (AC), and point-of-common-coupling (PCC) responses reach 534.2, 438.4, and 151.9 V, respectively. The corresponding peak changes relative to the source are , , , and dB. The DC-side response contains a dominant damped oscillation near 0.61 MHz, and the AC/PCC transfer varies markedly across 0.2–2.0 MHz. In a separate control-identical comparison over the first 2.5 s, the field-identified and lumped models give DC-side peaks of 171.9 and 1.23 V and PCC peaks of 121.4 and 3.93 V under the same excitation. The framework connects field-identified equipment terminal behavior with station-level time-domain propagation analysis and provides a modeling basis for broadband resonance screening and conducted electromagnetic-interference (EMI) assessment. - 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- p. 1
A Review on Electric Field-Assisted Enhancement of Electrical and Thermal Performance of Advanced Insulation Materials: Mechanisms, Properties, and Applications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- p. 1
A Review on Electric Field-Assisted Enhancement of Electrical and Thermal Performance of Advanced Insulation Materials: Mechanisms, Properties, and Applications
- Open Access
- 10 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (22) , 4380
An Intelligent Suppression Method for Interference Pulses in Partial Discharge Detection of Transformers Based on Waveform Feature Recognition
High-frequency current detection of partial discharge (PD) at transformers on-site faces complex noise interference, which severely impacts the accuracy of PD detection. To address this issue, an intelligent interference suppression algorithm for PD signals based on adaptive waveform feature recognition is proposed. First, a 10 MHz high-pass filter is applied to eliminate the influence of periodic narrowband interference on the zero-crossing count of the time-series. Non-pulse noise is removed based on the instantaneous zero-crossing density of the signal. Next, the start and end times of each pulse are determined, and the corresponding waveform segments are extracted from the original signal to form a pulse array. Subsequently, waveform features of the pulses are extracted, and discrimination thresholds for the feature parameters are calculated based on univariate analysis. Finally, each pulse is adaptively identified based on its waveform features, and PD signals are screened out. The proposed algorithm was tested using PD signals superimposed with on-site noise as well as field-measured signals. The results demonstrate that the algorithm can intelligently identify PD signals and significantly reduce PD signal attenuation, exhibiting excellent suppression effects on complex noise interference in on-site PD detection at transformers.
- 10 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (22) , 4380
Open AccessAn Intelligent Suppression Method for Interference Pulses in Partial Discharge Detection of Transformers Based on Waveform Feature Recognition
High-frequency current detection of partial discharge (PD) at transformers on-site faces complex noise interference, which severely impacts the accuracy of PD detection. To address this issue, an intelligent interference suppression algorithm for PD signals based on adaptive waveform feature recognition is proposed. First, a 10 MHz high-pass filter is applied to eliminate the influence of periodic narrowband interference on the zero-crossing count of the time-series. Non-pulse noise is removed based on the instantaneous zero-crossing density of the signal. Next, the start and end times of each pulse are determined, and the corresponding waveform segments are extracted from the original signal to form a pulse array. Subsequently, waveform features of the pulses are extracted, and discrimination thresholds for the feature parameters are calculated based on univariate analysis. Finally, each pulse is adaptively identified based on its waveform features, and PD signals are screened out. The proposed algorithm was tested using PD signals superimposed with on-site noise as well as field-measured signals. The results demonstrate that the algorithm can intelligently identify PD signals and significantly reduce PD signal attenuation, exhibiting excellent suppression effects on complex noise interference in on-site PD detection at transformers.
- 22 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3707-3717
Adaptive Separation Method for Interference Pulses in Partial Discharge Signals of Converter Transformers Based on IFCM Clustering
Wideband partial discharge (PD) detection has been widely applied due to its ability to retain rich discharge information. However, the presence of significant noise at converter stations severely interferes with on-site PD detection. Effectively separating PD from noise interference is key to improving the accuracy of wideband PD detection. Traditional denoising algorithms based on signal decomposition techniques can suppress noise, but they also lead to significant attenuation of PD signals. Signal separation techniques based on waveform features can retain the complete waveform and reduce PD signals attenuation, emerging as a new trend in denoising. However, existing algorithms based on clustering are affected by data distribution, making it difficult to effectively separate PD signals from interference pulses, causing noticeable noise residue. Moreover, these algorithms struggle to directly handle long-duration signals collected on-site, as the signals first require extracting each pulse individually. To solve the problems, this paper proposes a denoising algorithm based on adaptive separation of interference pulses. Initially, pulse waveforms are extracted from the raw signal based on the instantaneous rate of change of energy in the time-series, thereby removing non-pulse noise. Then, using the -20dB bandwidth, kurtosis, and peak factor of the pulse waveforms as features, an iterative Fuzzy C-Means (IFCM) clustering is applied to progressively separate interference pulses, ultimately preserving PD signals. The denoising results for PD signals from the laboratory, superimposed with on-site noise, and measured signals from on-site discharge calibration and PD testing demonstrate that the algorithm can adaptively remove complex interference while fully preserving the PD signals.
- 22 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3707-3717
Adaptive Separation Method for Interference Pulses in Partial Discharge Signals of Converter Transformers Based on IFCM Clustering
Wideband partial discharge (PD) detection has been widely applied due to its ability to retain rich discharge information. However, the presence of significant noise at converter stations severely interferes with on-site PD detection. Effectively separating PD from noise interference is key to improving the accuracy of wideband PD detection. Traditional denoising algorithms based on signal decomposition techniques can suppress noise, but they also lead to significant attenuation of PD signals. Signal separation techniques based on waveform features can retain the complete waveform and reduce PD signals attenuation, emerging as a new trend in denoising. However, existing algorithms based on clustering are affected by data distribution, making it difficult to effectively separate PD signals from interference pulses, causing noticeable noise residue. Moreover, these algorithms struggle to directly handle long-duration signals collected on-site, as the signals first require extracting each pulse individually. To solve the problems, this paper proposes a denoising algorithm based on adaptive separation of interference pulses. Initially, pulse waveforms are extracted from the raw signal based on the instantaneous rate of change of energy in the time-series, thereby removing non-pulse noise. Then, using the -20dB bandwidth, kurtosis, and peak factor of the pulse waveforms as features, an iterative Fuzzy C-Means (IFCM) clustering is applied to progressively separate interference pulses, ultimately preserving PD signals. The denoising results for PD signals from the laboratory, superimposed with on-site noise, and measured signals from on-site discharge calibration and PD testing demonstrate that the algorithm can adaptively remove complex interference while fully preserving the PD signals.
- Open Access
- 24 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1730
Adaptive Suppression Method for Periodic Pulsation Interference in Partial Discharge of Converter Transformers Based on Periodic Consistency Scoring and Waveform Characteristics
The online monitoring of partial discharge (PD) in converter transformers faces significant noise interference. Among these, the periodic pulsating interference caused by the switching process of thyristors is particularly challenging to directly identify from waveforms or frequency spectra, which affects the accuracy of PD monitoring. To address this, a time-domain multi-feature joint recognition algorithm based on periodic consistency scoring and waveform characteristics is proposed. Firstly, the timestamps of each pulse in the signal sequence are extracted based on the cumulative energy function. Secondly, the periodic consistency score and time–frequency feature parameters of each pulse are extracted separately, and an optimal recognition vector is constructed based on univariate screening and redundancy feature checking. Finally, dimensionality reduction is performed using principal component analysis, and the PD signals are separated from periodic pulse interference through fuzzy C-means clustering. The proposed algorithm is applied to denoise PD signals superimposed with on-site noise interference and field-measured signals. The results demonstrate that the algorithm effectively suppresses periodic pulsation interference while significantly reducing the attenuation of PD signals during the denoising process.
- 24 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1730
Open AccessAdaptive Suppression Method for Periodic Pulsation Interference in Partial Discharge of Converter Transformers Based on Periodic Consistency Scoring and Waveform Characteristics
The online monitoring of partial discharge (PD) in converter transformers faces significant noise interference. Among these, the periodic pulsating interference caused by the switching process of thyristors is particularly challenging to directly identify from waveforms or frequency spectra, which affects the accuracy of PD monitoring. To address this, a time-domain multi-feature joint recognition algorithm based on periodic consistency scoring and waveform characteristics is proposed. Firstly, the timestamps of each pulse in the signal sequence are extracted based on the cumulative energy function. Secondly, the periodic consistency score and time–frequency feature parameters of each pulse are extracted separately, and an optimal recognition vector is constructed based on univariate screening and redundancy feature checking. Finally, dimensionality reduction is performed using principal component analysis, and the PD signals are separated from periodic pulse interference through fuzzy C-means clustering. The proposed algorithm is applied to denoise PD signals superimposed with on-site noise interference and field-measured signals. The results demonstrate that the algorithm effectively suppresses periodic pulsation interference while significantly reducing the attenuation of PD signals during the denoising process.
- 20 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (2) , 1181-1190
A Winding-Core High-Frequency Equivalent Circuit Model for Exactly Simulating Partial Discharge Signals Propagation in Transformer
Wideband partial discharge (PD) detection, with its high bandwidth and strong anti-interference capabilities, is an inevitable trend in the development of discharge detection technology. However, the intricate propagation paths and attenuation patterns of high-frequency signals pose challenges for wideband detection of PD, especially in converter transformers. To study the transient response of transformer windings to wideband PD signals, equivalent circuit model is an excellent method. However, conventional equivalent circuit model generally only applies to frequency below 1MHz. For converter transformers, this equivalent circuit model is insufficient due to strong interference exiting in such frequency band. To solve the problems, this paper proposes a winding-core high-frequency equivalent circuit model. Multiple RLC parallel resonant units are added to the circuit model of the interleaved winding, and a transverse capacitance between the high-voltage winding and the core yoke is also included in the model. Experimental tests on a transformer demonstrate that the improved model can accurately simulate the impedance characteristics of windings up to a frequency of 10MHz. Compared to the conventional model, the improved model significantly enhances the similarity between simulated signals and measured signals. It can accurately characterize the attenuation of different frequency components within the 10MHz range, addressing the challenge conventional model faces in simulating signals at the core grounding point.
- 20 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (2) , 1181-1190
A Winding-Core High-Frequency Equivalent Circuit Model for Exactly Simulating Partial Discharge Signals Propagation in Transformer
Wideband partial discharge (PD) detection, with its high bandwidth and strong anti-interference capabilities, is an inevitable trend in the development of discharge detection technology. However, the intricate propagation paths and attenuation patterns of high-frequency signals pose challenges for wideband detection of PD, especially in converter transformers. To study the transient response of transformer windings to wideband PD signals, equivalent circuit model is an excellent method. However, conventional equivalent circuit model generally only applies to frequency below 1MHz. For converter transformers, this equivalent circuit model is insufficient due to strong interference exiting in such frequency band. To solve the problems, this paper proposes a winding-core high-frequency equivalent circuit model. Multiple RLC parallel resonant units are added to the circuit model of the interleaved winding, and a transverse capacitance between the high-voltage winding and the core yoke is also included in the model. Experimental tests on a transformer demonstrate that the improved model can accurately simulate the impedance characteristics of windings up to a frequency of 10MHz. Compared to the conventional model, the improved model significantly enhances the similarity between simulated signals and measured signals. It can accurately characterize the attenuation of different frequency components within the 10MHz range, addressing the challenge conventional model faces in simulating signals at the core grounding point.