Tong Bai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tong Bai has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Haibao Mu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
4 shared publications - Zekai Lai
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
3 shared publications - Bing Yu
Electric Power Research Institute, State Grid Zhejiang Electric Power Co., Ltd., Hangzhou 310014, China
2 shared publications - Maoqun Shen
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
2 shared publications Bing Yu
State Grid Zhejiang Electric Power Research Institute, Hangzhou, Zhejiang, China
1 shared publication- Chenhui Zhou
State Key Lab of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication
Latest Publications
- Open Access
- 27 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (17) , 3860
Field-Measurement-Based Wideband Modeling and System-Level Simulation of MMC-HVDC Converter Stations for High-Frequency Disturbance Studies
This study establishes a field-measurement-based wideband modeling and station-level simulation framework for conducted high-frequency (HF) disturbance studies in modular multilevel converter-based high-voltage direct-current (MMC-HVDC) stations. Full-scale engineering-site frequency-response measurements are used to identify kHz-to-MHz terminal models of the arm reactor and the valve-side winding of the converter transformer. The arm reactor is fitted in the admittance domain by vector fitting and synthesized as a passive parallel network containing the main inductive path and multiple damped resistor–inductor–capacitor (RLC) branches. The transformer valve-side winding is represented by a Foster I/II hybrid -type terminal network reconstructed from two single-phase port-impedance measurements. The validated equipment models are integrated into a representative Power Systems Computer-Aided Design (PSCAD) station model. A 2 ms valve-side source sequence, constructed from nearest-level-control switching instants and a parameterized switching-transient template, is applied in paired injection and zero-injection simulations. For the representative event, the source peak is 605.6 V. Over the first 4 s, the arm-reactor terminal reaches 972.6 V, while the direct-current (DC)-side, valve-side alternating-current (AC), and point-of-common-coupling (PCC) responses reach 534.2, 438.4, and 151.9 V, respectively. The corresponding peak changes relative to the source are , , , and dB. The DC-side response contains a dominant damped oscillation near 0.61 MHz, and the AC/PCC transfer varies markedly across 0.2–2.0 MHz. In a separate control-identical comparison over the first 2.5 s, the field-identified and lumped models give DC-side peaks of 171.9 and 1.23 V and PCC peaks of 121.4 and 3.93 V under the same excitation. The framework connects field-identified equipment terminal behavior with station-level time-domain propagation analysis and provides a modeling basis for broadband resonance screening and conducted electromagnetic-interference (EMI) assessment.- 27 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (17) , 3860
Open AccessField-Measurement-Based Wideband Modeling and System-Level Simulation of MMC-HVDC Converter Stations for High-Frequency Disturbance Studies
This study establishes a field-measurement-based wideband modeling and station-level simulation framework for conducted high-frequency (HF) disturbance studies in modular multilevel converter-based high-voltage direct-current (MMC-HVDC) stations. Full-scale engineering-site frequency-response measurements are used to identify kHz-to-MHz terminal models of the arm reactor and the valve-side winding of the converter transformer. The arm reactor is fitted in the admittance domain by vector fitting and synthesized as a passive parallel network containing the main inductive path and multiple damped resistor–inductor–capacitor (RLC) branches. The transformer valve-side winding is represented by a Foster I/II hybrid -type terminal network reconstructed from two single-phase port-impedance measurements. The validated equipment models are integrated into a representative Power Systems Computer-Aided Design (PSCAD) station model. A 2 ms valve-side source sequence, constructed from nearest-level-control switching instants and a parameterized switching-transient template, is applied in paired injection and zero-injection simulations. For the representative event, the source peak is 605.6 V. Over the first 4 s, the arm-reactor terminal reaches 972.6 V, while the direct-current (DC)-side, valve-side alternating-current (AC), and point-of-common-coupling (PCC) responses reach 534.2, 438.4, and 151.9 V, respectively. The corresponding peak changes relative to the source are , , , and dB. The DC-side response contains a dominant damped oscillation near 0.61 MHz, and the AC/PCC transfer varies markedly across 0.2–2.0 MHz. In a separate control-identical comparison over the first 2.5 s, the field-identified and lumped models give DC-side peaks of 171.9 and 1.23 V and PCC peaks of 121.4 and 3.93 V under the same excitation. The framework connects field-identified equipment terminal behavior with station-level time-domain propagation analysis and provides a modeling basis for broadband resonance screening and conducted electromagnetic-interference (EMI) assessment. - Open Access
- 10 February 2026
- Published by MDPI AG in Electronics
- Vol. 15 (4) , 751
Analysis and Adaptive Separation of IGBT Switching Noise in PD Monitoring of Flexible HVDC Valves: An Evolutionary Perspective
The high-frequency switching noise of insulated-gate bipolar transistors (IGBTs) limits the sensitivity of online partial discharge (PD) monitoring in ultra-high-voltage flexible DC (VSC-HVDC) transmission systems. To address this challenge, this study investigates the underlying mechanisms and evolution of this interference and develops an anti-interference signal separation method. Simulation and experimental results indicate that the energy of IGBT switching noise is concentrated in the 30–180 MHz range, which significantly overlaps with the ultra-high-frequency (UHF) band used for PD detection. This research further reveals the pronounced modulation effect of device aging on the interference spectrum: bond wire aging triggers “spectral reconstruction” via altered parasitic parameters, where severe collector aging leads to an abnormal surge in turn-off interference amplitude. In contrast, gate oxide layer degradation manifests as characteristic “global spectrum attenuation” and a shift in peak frequency toward lower bands. Confronted with the challenges of strong interference and spectrum drift induced by aging, this paper proposes an adaptive signal separation method based on feature optimization of the time–frequency cumulative energy function. This method constructs novel characteristic parameters—namely, oblique intercept width and morphological gradient steepness—to effectively capture the fundamental differences in the energy accumulation process of the signals. Experimental verification demonstrates that even under conditions of varying interference characteristics, the proposed method achieves high-precision separation of PD signals from IGBT noise, outperforming traditional equivalent time–frequency and wavelet principal component analysis methods. This research provides crucial theoretical and technical support for insulation condition monitoring and device aging diagnosis in VSC-HVDC converter valves.
- 10 February 2026
- Published by MDPI AG in Electronics
- Vol. 15 (4) , 751
Open AccessAnalysis and Adaptive Separation of IGBT Switching Noise in PD Monitoring of Flexible HVDC Valves: An Evolutionary Perspective
The high-frequency switching noise of insulated-gate bipolar transistors (IGBTs) limits the sensitivity of online partial discharge (PD) monitoring in ultra-high-voltage flexible DC (VSC-HVDC) transmission systems. To address this challenge, this study investigates the underlying mechanisms and evolution of this interference and develops an anti-interference signal separation method. Simulation and experimental results indicate that the energy of IGBT switching noise is concentrated in the 30–180 MHz range, which significantly overlaps with the ultra-high-frequency (UHF) band used for PD detection. This research further reveals the pronounced modulation effect of device aging on the interference spectrum: bond wire aging triggers “spectral reconstruction” via altered parasitic parameters, where severe collector aging leads to an abnormal surge in turn-off interference amplitude. In contrast, gate oxide layer degradation manifests as characteristic “global spectrum attenuation” and a shift in peak frequency toward lower bands. Confronted with the challenges of strong interference and spectrum drift induced by aging, this paper proposes an adaptive signal separation method based on feature optimization of the time–frequency cumulative energy function. This method constructs novel characteristic parameters—namely, oblique intercept width and morphological gradient steepness—to effectively capture the fundamental differences in the energy accumulation process of the signals. Experimental verification demonstrates that even under conditions of varying interference characteristics, the proposed method achieves high-precision separation of PD signals from IGBT noise, outperforming traditional equivalent time–frequency and wavelet principal component analysis methods. This research provides crucial theoretical and technical support for insulation condition monitoring and device aging diagnosis in VSC-HVDC converter valves.
- 22 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3707-3717
Adaptive Separation Method for Interference Pulses in Partial Discharge Signals of Converter Transformers Based on IFCM Clustering
Wideband partial discharge (PD) detection has been widely applied due to its ability to retain rich discharge information. However, the presence of significant noise at converter stations severely interferes with on-site PD detection. Effectively separating PD from noise interference is key to improving the accuracy of wideband PD detection. Traditional denoising algorithms based on signal decomposition techniques can suppress noise, but they also lead to significant attenuation of PD signals. Signal separation techniques based on waveform features can retain the complete waveform and reduce PD signals attenuation, emerging as a new trend in denoising. However, existing algorithms based on clustering are affected by data distribution, making it difficult to effectively separate PD signals from interference pulses, causing noticeable noise residue. Moreover, these algorithms struggle to directly handle long-duration signals collected on-site, as the signals first require extracting each pulse individually. To solve the problems, this paper proposes a denoising algorithm based on adaptive separation of interference pulses. Initially, pulse waveforms are extracted from the raw signal based on the instantaneous rate of change of energy in the time-series, thereby removing non-pulse noise. Then, using the -20dB bandwidth, kurtosis, and peak factor of the pulse waveforms as features, an iterative Fuzzy C-Means (IFCM) clustering is applied to progressively separate interference pulses, ultimately preserving PD signals. The denoising results for PD signals from the laboratory, superimposed with on-site noise, and measured signals from on-site discharge calibration and PD testing demonstrate that the algorithm can adaptively remove complex interference while fully preserving the PD signals.
- 22 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (6) , 3707-3717
Adaptive Separation Method for Interference Pulses in Partial Discharge Signals of Converter Transformers Based on IFCM Clustering
Wideband partial discharge (PD) detection has been widely applied due to its ability to retain rich discharge information. However, the presence of significant noise at converter stations severely interferes with on-site PD detection. Effectively separating PD from noise interference is key to improving the accuracy of wideband PD detection. Traditional denoising algorithms based on signal decomposition techniques can suppress noise, but they also lead to significant attenuation of PD signals. Signal separation techniques based on waveform features can retain the complete waveform and reduce PD signals attenuation, emerging as a new trend in denoising. However, existing algorithms based on clustering are affected by data distribution, making it difficult to effectively separate PD signals from interference pulses, causing noticeable noise residue. Moreover, these algorithms struggle to directly handle long-duration signals collected on-site, as the signals first require extracting each pulse individually. To solve the problems, this paper proposes a denoising algorithm based on adaptive separation of interference pulses. Initially, pulse waveforms are extracted from the raw signal based on the instantaneous rate of change of energy in the time-series, thereby removing non-pulse noise. Then, using the -20dB bandwidth, kurtosis, and peak factor of the pulse waveforms as features, an iterative Fuzzy C-Means (IFCM) clustering is applied to progressively separate interference pulses, ultimately preserving PD signals. The denoising results for PD signals from the laboratory, superimposed with on-site noise, and measured signals from on-site discharge calibration and PD testing demonstrate that the algorithm can adaptively remove complex interference while fully preserving the PD signals.
- Open Access
- 24 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1730
Adaptive Suppression Method for Periodic Pulsation Interference in Partial Discharge of Converter Transformers Based on Periodic Consistency Scoring and Waveform Characteristics
The online monitoring of partial discharge (PD) in converter transformers faces significant noise interference. Among these, the periodic pulsating interference caused by the switching process of thyristors is particularly challenging to directly identify from waveforms or frequency spectra, which affects the accuracy of PD monitoring. To address this, a time-domain multi-feature joint recognition algorithm based on periodic consistency scoring and waveform characteristics is proposed. Firstly, the timestamps of each pulse in the signal sequence are extracted based on the cumulative energy function. Secondly, the periodic consistency score and time–frequency feature parameters of each pulse are extracted separately, and an optimal recognition vector is constructed based on univariate screening and redundancy feature checking. Finally, dimensionality reduction is performed using principal component analysis, and the PD signals are separated from periodic pulse interference through fuzzy C-means clustering. The proposed algorithm is applied to denoise PD signals superimposed with on-site noise interference and field-measured signals. The results demonstrate that the algorithm effectively suppresses periodic pulsation interference while significantly reducing the attenuation of PD signals during the denoising process.
- 24 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1730
Open AccessAdaptive Suppression Method for Periodic Pulsation Interference in Partial Discharge of Converter Transformers Based on Periodic Consistency Scoring and Waveform Characteristics
The online monitoring of partial discharge (PD) in converter transformers faces significant noise interference. Among these, the periodic pulsating interference caused by the switching process of thyristors is particularly challenging to directly identify from waveforms or frequency spectra, which affects the accuracy of PD monitoring. To address this, a time-domain multi-feature joint recognition algorithm based on periodic consistency scoring and waveform characteristics is proposed. Firstly, the timestamps of each pulse in the signal sequence are extracted based on the cumulative energy function. Secondly, the periodic consistency score and time–frequency feature parameters of each pulse are extracted separately, and an optimal recognition vector is constructed based on univariate screening and redundancy feature checking. Finally, dimensionality reduction is performed using principal component analysis, and the PD signals are separated from periodic pulse interference through fuzzy C-means clustering. The proposed algorithm is applied to denoise PD signals superimposed with on-site noise interference and field-measured signals. The results demonstrate that the algorithm effectively suppresses periodic pulsation interference while significantly reducing the attenuation of PD signals during the denoising process.