Mesay Dejene Altaye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mesay Dejene Altaye has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Manzoore Elahi M. Soudagar
College of Engineering, Lishui University, Lishui, China
2 shared publicationsP. V. Elumalai
Department of Mechanical Engineering, Aditya University, Surampalem, India
2 shared publicationsBhaskar Jyoti Medhi
Assam Energy Institute Sivasagar, A Centre of Rajiv Gandhi Institute of Petroleum Technology, Sivasagar, India
1 shared publication- Bhaskor Jyoti Bora
Assam Energy Institute, Sivasagar, a centre of Rajiv Gandhi Institute of Petroleum Technology, Sivasagar, India
1 shared publication Chinmoy Jit Sarma
Assam Energy Institute Sivasagar, A Centre of Rajiv Gandhi Institute of Petroleum Technology, Sivasagar, India
1 shared publicationDebabrata Barik
Department of Mechanical Engineering, Karpagam Academy of Higher Education, Coimbatore, India
1 shared publication
Latest Publications
- Open Access
- 1 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-17
Analysis of the pooled effect of compression ratio and injection timing variation on conventional diesel engine powered with nano doped biodiesel blend
This research aims to explore how incorporating nanoparticles into a biodiesel-diesel blend influences the performance, combustion, and emission characteristics of a diesel engine under varying conditions, including compression ratios, engine loads, and injection timings. The biodiesel and nanoparticles considered for this investigation are mahua biodiesel and Titanium oxide nanoparticles (TiO2), respectively. The experimental fuel is formulated by blending diesel and mahua biodiesel with the addition of titanium oxide nanoparticles. In this study, compression ratio is varied from 17.5 to 18, whereas fuel injection timing of 20°, 23°, and 25° BTDCs along with engine load variation of 20%, 40%, 60%, 80%, and 100% are considered. The experimentation utilized a single-cylinder diesel engine equipped with a variable compression ratio (VCR) feature and a power output of 3.5 kW. The results indicate that the maximum brake thermal efficiency was achieved at a compression ratio of 18 and a fuel injection timing of 20° before Top Dead Center. For the same setting, the nanoparticle-enriched biodiesel-diesel blend exhibited the lowest levels of CO and HC emissions among all test runs, with reductions of 45.34% and 40%, respectively, compared to standard diesel operation.
- 1 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-17
Open AccessAnalysis of the pooled effect of compression ratio and injection timing variation on conventional diesel engine powered with nano doped biodiesel blend
This research aims to explore how incorporating nanoparticles into a biodiesel-diesel blend influences the performance, combustion, and emission characteristics of a diesel engine under varying conditions, including compression ratios, engine loads, and injection timings. The biodiesel and nanoparticles considered for this investigation are mahua biodiesel and Titanium oxide nanoparticles (TiO2), respectively. The experimental fuel is formulated by blending diesel and mahua biodiesel with the addition of titanium oxide nanoparticles. In this study, compression ratio is varied from 17.5 to 18, whereas fuel injection timing of 20°, 23°, and 25° BTDCs along with engine load variation of 20%, 40%, 60%, 80%, and 100% are considered. The experimentation utilized a single-cylinder diesel engine equipped with a variable compression ratio (VCR) feature and a power output of 3.5 kW. The results indicate that the maximum brake thermal efficiency was achieved at a compression ratio of 18 and a fuel injection timing of 20° before Top Dead Center. For the same setting, the nanoparticle-enriched biodiesel-diesel blend exhibited the lowest levels of CO and HC emissions among all test runs, with reductions of 45.34% and 40%, respectively, compared to standard diesel operation.
- Open Access
- 5 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 19717
Wear and frictional behaviour of partially oxidized and plasma sprayed NiCr and NiCrBSiFe coatings
The wear performance of partially oxidized NiCr and NiCrBSiFe coatings were investigated by varing load and speed. The partial oxidized powders were processed from the alloy powder using a flame spray process that involved spraying into distilled water. The partially oxidized powder was then plasma-sprayed onto MDN321 steel. The coatings were characterized for adhesive strength, microhardness, and density. The wear behavior was evaluated at disc speeds of 1, 2, and 3 m/s, with loads ranging from 10 to 50 N, over a 3000 m sliding distance. A significant difference in wear rates between the coating and substrate was observed. Operating at a sliding velocity of 1 m/s under a 10 N load, the substrate's wear rate was found to be 3.56 times higher than that of the NiCrBSiFe coating, whereas for NiCr coating, it was 2.78 times higher. Wear rate coefficient performance shift takes place between the coatings at 12 N-m/s, product of applied load (C) and sliding velocity (V). In NiCrBSiFe coating, the wear mechanism observed at lower speeds and loads is micro-brittle and mechanism shifts to abrasive wear at higher speeds and loads. In the NiCr partially oxidized coating, the wear mechanism observed involves spallation of the coating at higher loads and adhesive wear at lower loads. Thermo gravimetric analysis of the coatings revealed a weight loss percentage of 1.42 for NiCrBSiFe and 14.09 for NiCr coatings. These findings highlight the NiCrBSiFe partially oxidized coating as being tenfold more stable at high temperatures compared to the NiCr partially oxidized coating.
- 5 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 19717
Open AccessWear and frictional behaviour of partially oxidized and plasma sprayed NiCr and NiCrBSiFe coatings
The wear performance of partially oxidized NiCr and NiCrBSiFe coatings were investigated by varing load and speed. The partial oxidized powders were processed from the alloy powder using a flame spray process that involved spraying into distilled water. The partially oxidized powder was then plasma-sprayed onto MDN321 steel. The coatings were characterized for adhesive strength, microhardness, and density. The wear behavior was evaluated at disc speeds of 1, 2, and 3 m/s, with loads ranging from 10 to 50 N, over a 3000 m sliding distance. A significant difference in wear rates between the coating and substrate was observed. Operating at a sliding velocity of 1 m/s under a 10 N load, the substrate's wear rate was found to be 3.56 times higher than that of the NiCrBSiFe coating, whereas for NiCr coating, it was 2.78 times higher. Wear rate coefficient performance shift takes place between the coatings at 12 N-m/s, product of applied load (C) and sliding velocity (V). In NiCrBSiFe coating, the wear mechanism observed at lower speeds and loads is micro-brittle and mechanism shifts to abrasive wear at higher speeds and loads. In the NiCr partially oxidized coating, the wear mechanism observed involves spallation of the coating at higher loads and adhesive wear at lower loads. Thermo gravimetric analysis of the coatings revealed a weight loss percentage of 1.42 for NiCrBSiFe and 14.09 for NiCr coatings. These findings highlight the NiCrBSiFe partially oxidized coating as being tenfold more stable at high temperatures compared to the NiCr partially oxidized coating.
- Open Access
- 11 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Performance optimization for solar photovoltaic thermal system with spiral rectangular absorber using Taguchi method
Solar collector systems efficiently transform sunlight into energy that may be used to meet various needs. This research aimed to use the Taguchi method to determine the ideal operating parameters for a solar thermal collector with a rectangular spiral absorber. Controllable parameters including mass flow rate, solar radiation, and absorber design were manipulated during the energy recovery process, and features like PV temperature and outlet water temperature were used to assess the system’s effectiveness. The findings indicate that certain criteria significantly affect response indicators. The observed percentage contribution of absorber design, solar radiation, and the mass flow rate was 69.19%, 27.99%, and 2.83% in PV surface temperature. In comparison, the individual percentage contributions were 73.63%, 13.51%, and 10.57% for absorber design, solar radiation and mass flow rate for water output temperatures. The present model’s R2 values for PV and outlet water temperatures are 97.24% and 99.67%, respectively. The Predictive regression model was found in fine harmony and the maximum percentage error is limited to 0.68%. The maximum analytical electrical efficiency was observed with a spiral rectangular absorber of 14.57% at the lowest mass flow rate of 0.04 kg/s at the lowest radiation level of 600 W/m2. In comparison, maximum analytical thermal efficiency was observed with a spiral rectangular thermal absorber of 63.56% at the highest flow rate of 0.06 kg/s and the highest solar radiation level of 1000 W/m2. The analytical and experiment findings were in better agreement in this study, with the highest relative error of 7.52%. According to the study’s findings, the rectangular absorber-based PVT system is at its best at a higher mass flow rate to lower PV temperature and boost thermal energy recovery via water. The present research work can be extended for exergy, environmental, and economic feasibility analysis.
- 11 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-13
Open AccessPerformance optimization for solar photovoltaic thermal system with spiral rectangular absorber using Taguchi method
Solar collector systems efficiently transform sunlight into energy that may be used to meet various needs. This research aimed to use the Taguchi method to determine the ideal operating parameters for a solar thermal collector with a rectangular spiral absorber. Controllable parameters including mass flow rate, solar radiation, and absorber design were manipulated during the energy recovery process, and features like PV temperature and outlet water temperature were used to assess the system’s effectiveness. The findings indicate that certain criteria significantly affect response indicators. The observed percentage contribution of absorber design, solar radiation, and the mass flow rate was 69.19%, 27.99%, and 2.83% in PV surface temperature. In comparison, the individual percentage contributions were 73.63%, 13.51%, and 10.57% for absorber design, solar radiation and mass flow rate for water output temperatures. The present model’s R2 values for PV and outlet water temperatures are 97.24% and 99.67%, respectively. The Predictive regression model was found in fine harmony and the maximum percentage error is limited to 0.68%. The maximum analytical electrical efficiency was observed with a spiral rectangular absorber of 14.57% at the lowest mass flow rate of 0.04 kg/s at the lowest radiation level of 600 W/m2. In comparison, maximum analytical thermal efficiency was observed with a spiral rectangular thermal absorber of 63.56% at the highest flow rate of 0.06 kg/s and the highest solar radiation level of 1000 W/m2. The analytical and experiment findings were in better agreement in this study, with the highest relative error of 7.52%. According to the study’s findings, the rectangular absorber-based PVT system is at its best at a higher mass flow rate to lower PV temperature and boost thermal energy recovery via water. The present research work can be extended for exergy, environmental, and economic feasibility analysis.