Tanner K. Nelson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tanner K. Nelson has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ivan Cardenas
Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA
4 shared publications - Jeff H. Pettey
Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA
4 shared publications - Randall J. Olson
Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA
4 shared publications - Reiker G. Ricks
Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA
4 shared publications - Jenna L. Jensen
Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA
3 shared publications - Tyler Whitaker
Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
2 shared publications
Latest Publications
- Open Access
- 1 October 2025
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. ume 18, 485-493
Energy Output Variability Among Phacoemulsification Tips Using Calorimetry
Purpose: To determine if using different phacoemulsification (phaco) tips will impact thermal energy output utilizing calorimetry. Methods: The Alcon Centurion was used with the Infiniti OZil handpiece and balanced, hybrid, or MST Dewey A1 mini tip. Settings were 100% power, continuous torsional or longitudinal ultrasound, 0mmHg vacuum limit, and flow rate 12mL/min. Outflow tubing was removed from the handpiece and inflow tubing was manually occluded. The handpiece tip was placed into the calorimeter filled with 50mL of degassed deionized water and ultrasound was initiated for 1 minute. Temperature rise and cumulative dissipated energy (CDE) were recorded; ten trials were performed for each group. Results: Statistically significant differences in energy output, measured in Joules, were found between all three tips in both ultrasound modes. Balanced tips showed the highest output, Dewey tips had the lowest. Hybrid tips had significantly increased output in longitudinal mode, whereas Dewey tips had significantly decreased output in longitudinal mode. No significant differences were seen in CDE between tips in either ultrasound mode, but significant increases were seen in longitudinal mode within each tip. Conclusion: This study demonstrated differences in thermal energy production of three different phaco handpiece tips. This provides insight into how thermal injuries occur and what might cause these differences. Our methodology provides a novel way for accurate energy measurement at the tip, though it differs when compared to external energy production measurements. Surgeons should take into consideration the significant variability in thermal energy created by handpiece tips. Plain Language Summary: Modern cataract surgery employs phacoemulsification, a technique that breaks apart a cataract using ultrasonic energy. A rare but possible complication of this technology is thermal (heat) injury. Several factors contribute to energy generation during cataract fragmentation, such as friction at the incision site and impedance of flow rate. This study examines the thermal energy produced at the handpiece tip, where ultrasonic movement occurs. The energy delivered to the eye from the handpiece consists of mechanical energy in the form of kinetic and acoustic energy, leading to cavitation, mechanical disruption of the lens, and heat. It remains unclear how the design of phacoemulsification tips influences the energy transfer from piezoelectric crystals to the mechanical energy delivered to the eye. We used calorimetry to measure the thermal energy output, measured in Joules, between three different tips in longitudinal (forward and backward) and torsional (side to side) ultrasound modes, using the same settings, handpiece, and machine. The handpiece tip was submerged in the calorimetry chamber with water and operated for 60 seconds; a temperature probe measured the temperature change. The temperature changes were converted to energy and compared, and the energy measurement generated by the machine was recorded. We found significant differences in energy output between the three tips in both ultrasound modes, the Dewey tip demonstrated the lowest energy output and the balanced tip had the highest, in torsional and longitudinal mode. We found the measured energy differed significantly from the machine-generated measurement. These findings highlight the variability in energy output and expand on the potential contributing factors to energy generation and thermal injury in cataract surgery.
- 1 October 2025
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. ume 18, 485-493
Open AccessEnergy Output Variability Among Phacoemulsification Tips Using Calorimetry
Purpose: To determine if using different phacoemulsification (phaco) tips will impact thermal energy output utilizing calorimetry. Methods: The Alcon Centurion was used with the Infiniti OZil handpiece and balanced, hybrid, or MST Dewey A1 mini tip. Settings were 100% power, continuous torsional or longitudinal ultrasound, 0mmHg vacuum limit, and flow rate 12mL/min. Outflow tubing was removed from the handpiece and inflow tubing was manually occluded. The handpiece tip was placed into the calorimeter filled with 50mL of degassed deionized water and ultrasound was initiated for 1 minute. Temperature rise and cumulative dissipated energy (CDE) were recorded; ten trials were performed for each group. Results: Statistically significant differences in energy output, measured in Joules, were found between all three tips in both ultrasound modes. Balanced tips showed the highest output, Dewey tips had the lowest. Hybrid tips had significantly increased output in longitudinal mode, whereas Dewey tips had significantly decreased output in longitudinal mode. No significant differences were seen in CDE between tips in either ultrasound mode, but significant increases were seen in longitudinal mode within each tip. Conclusion: This study demonstrated differences in thermal energy production of three different phaco handpiece tips. This provides insight into how thermal injuries occur and what might cause these differences. Our methodology provides a novel way for accurate energy measurement at the tip, though it differs when compared to external energy production measurements. Surgeons should take into consideration the significant variability in thermal energy created by handpiece tips. Plain Language Summary: Modern cataract surgery employs phacoemulsification, a technique that breaks apart a cataract using ultrasonic energy. A rare but possible complication of this technology is thermal (heat) injury. Several factors contribute to energy generation during cataract fragmentation, such as friction at the incision site and impedance of flow rate. This study examines the thermal energy produced at the handpiece tip, where ultrasonic movement occurs. The energy delivered to the eye from the handpiece consists of mechanical energy in the form of kinetic and acoustic energy, leading to cavitation, mechanical disruption of the lens, and heat. It remains unclear how the design of phacoemulsification tips influences the energy transfer from piezoelectric crystals to the mechanical energy delivered to the eye. We used calorimetry to measure the thermal energy output, measured in Joules, between three different tips in longitudinal (forward and backward) and torsional (side to side) ultrasound modes, using the same settings, handpiece, and machine. The handpiece tip was submerged in the calorimetry chamber with water and operated for 60 seconds; a temperature probe measured the temperature change. The temperature changes were converted to energy and compared, and the energy measurement generated by the machine was recorded. We found significant differences in energy output between the three tips in both ultrasound modes, the Dewey tip demonstrated the lowest energy output and the balanced tip had the highest, in torsional and longitudinal mode. We found the measured energy differed significantly from the machine-generated measurement. These findings highlight the variability in energy output and expand on the potential contributing factors to energy generation and thermal injury in cataract surgery.
- Open Access
- 1 January 2025
- Published by Wiley in Journal of Ophthalmology
- Vol. 2025 (1) , 3264880
Comparison of Postocclusion Pressure Surge Between Pressure Sensing and Traditional Phacoemulsification Handpieces
Purpose: To compare the Active Sentry and OZil handpieces regarding their ability to prevent postocclusion surge. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. Design: Experimental study. Methods: This study used the Alcon Centurion surgical platform, with both OZil handpieces fitted with balanced tips. The quad preset was used with a vacuum of 500 mmHg, an aspiration flow of 50 mmHg, and an intraocular pressure (IOP) of 70 mmHg. A rubber disk was fixed within a sealed chamber fitted with an electric pressure sensor to monitor pressure changes. The phaco tip was inserted through a small opening, and the foot pedal was set to position two. The tip was put in contact with the fixed rubber disk to replicate tip occlusion and then pulled from the disk to simulate occlusion break. 10 trials were performed with each handpiece, and pressure changes were recorded electronically. Results: A significant difference ( p < 0.01) was found between the magnitude of postocclusion surge, as well as between the duration of postocclusion surge. Conclusion: The Active Sentry handpiece was found to have a decreased magnitude and shorter duration of postocclusion surge compared with the OZil, signifying that having the pressure sensor in the handpiece allows it to react to post‐occlusion surge more quickly and to decrease surge magnitude.
- 1 January 2025
- Published by Wiley in Journal of Ophthalmology
- Vol. 2025 (1) , 3264880
Open AccessComparison of Postocclusion Pressure Surge Between Pressure Sensing and Traditional Phacoemulsification Handpieces
Purpose: To compare the Active Sentry and OZil handpieces regarding their ability to prevent postocclusion surge. Setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. Design: Experimental study. Methods: This study used the Alcon Centurion surgical platform, with both OZil handpieces fitted with balanced tips. The quad preset was used with a vacuum of 500 mmHg, an aspiration flow of 50 mmHg, and an intraocular pressure (IOP) of 70 mmHg. A rubber disk was fixed within a sealed chamber fitted with an electric pressure sensor to monitor pressure changes. The phaco tip was inserted through a small opening, and the foot pedal was set to position two. The tip was put in contact with the fixed rubber disk to replicate tip occlusion and then pulled from the disk to simulate occlusion break. 10 trials were performed with each handpiece, and pressure changes were recorded electronically. Results: A significant difference ( p < 0.01) was found between the magnitude of postocclusion surge, as well as between the duration of postocclusion surge. Conclusion: The Active Sentry handpiece was found to have a decreased magnitude and shorter duration of postocclusion surge compared with the OZil, signifying that having the pressure sensor in the handpiece allows it to react to post‐occlusion surge more quickly and to decrease surge magnitude.
- Open Access
- 1 January 2025
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. ume 18, 29-35
Comparison of Ultrasound Energy Delivered to the Anterior Segment Across Different Phacoemulsification Surgical Platforms
Purpose: The aim of this study was to use calorimetry to understand the difference in energy transferred by three phacoemulsification surgical platforms to the eye. Patients and Methods: A phacoemulsification tip was lowered into a double-walled calorimeter filled with distilled water. The foot pedal was depressed for 30 seconds and the change in temperature of the water was measured by a temperature probe. Three phacoemulsification systems were compared: the Alcon Centurion, Johnson & Johnson Veritas and Oertli CataRhex 3. The following conditions remained constant across trials and platforms: continuous longitudinal ultrasound, flow rate 12mL/min, vacuum 0mmHg, and clamped inflow and outflow tubing. The different platforms were directly compared at 20%, 40%, 60%, 80% and 100% power. Results: A two-way ANOVA found a significant difference (P < 0.001) in overall energy output across all trials between the CataRhex 3, Centurion and Veritas with an F value of 63.97 and two degrees of freedom. Conclusion: Given identical settings, the amount of energy produced was significantly different across phacoemulsification platforms. This data can aid surgeons’ understanding of how power level by surgical platform can impact the amount of energy introduced into the anterior segment during cataract surgery. Plain Language Summary: Cataract surgery is one of the most commonly performed surgical procedures in the United States. The most common surgical technique used to remove cataracts is called phacoemulsification (phaco), which utilizes ultrasound energy to break up and remove cataracts. Utilizing phaco to emulsify cataracts is safe and effective; however, because of the delicate nature of the structures in the eye, the amount of ultrasound energy delivered during the surgery is an important consideration to avoid adverse outcomes. There are a variety of phaco platforms (machines) used for cataract surgery. While it is beneficial for surgeons to have many options of surgical platforms, proprietary engineering makes it difficult to know how these surgical platforms compare to one another, especially in important variables such as energy delivery to the eye. To date, it has been unknown how the amount of energy delivered by these phaco platforms differs, if at all, when using identical settings during surgery. We did this study to find out if there are energy differences. To do this research, our lab used calorimetry, which is a way of measuring energy transfer, to compare three different surgical platforms at the same settings. We found a statistically significant difference in amount of energy between these surgical platforms. These results are important because they may help surgeons to understand that the amount of energy delivered during cataract surgery will be different depending on which surgical platform they are using and help to prevent adverse outcomes caused by delivering too much energy to the eye.
- 1 January 2025
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. ume 18, 29-35
Open AccessComparison of Ultrasound Energy Delivered to the Anterior Segment Across Different Phacoemulsification Surgical Platforms
Purpose: The aim of this study was to use calorimetry to understand the difference in energy transferred by three phacoemulsification surgical platforms to the eye. Patients and Methods: A phacoemulsification tip was lowered into a double-walled calorimeter filled with distilled water. The foot pedal was depressed for 30 seconds and the change in temperature of the water was measured by a temperature probe. Three phacoemulsification systems were compared: the Alcon Centurion, Johnson & Johnson Veritas and Oertli CataRhex 3. The following conditions remained constant across trials and platforms: continuous longitudinal ultrasound, flow rate 12mL/min, vacuum 0mmHg, and clamped inflow and outflow tubing. The different platforms were directly compared at 20%, 40%, 60%, 80% and 100% power. Results: A two-way ANOVA found a significant difference (P < 0.001) in overall energy output across all trials between the CataRhex 3, Centurion and Veritas with an F value of 63.97 and two degrees of freedom. Conclusion: Given identical settings, the amount of energy produced was significantly different across phacoemulsification platforms. This data can aid surgeons’ understanding of how power level by surgical platform can impact the amount of energy introduced into the anterior segment during cataract surgery. Plain Language Summary: Cataract surgery is one of the most commonly performed surgical procedures in the United States. The most common surgical technique used to remove cataracts is called phacoemulsification (phaco), which utilizes ultrasound energy to break up and remove cataracts. Utilizing phaco to emulsify cataracts is safe and effective; however, because of the delicate nature of the structures in the eye, the amount of ultrasound energy delivered during the surgery is an important consideration to avoid adverse outcomes. There are a variety of phaco platforms (machines) used for cataract surgery. While it is beneficial for surgeons to have many options of surgical platforms, proprietary engineering makes it difficult to know how these surgical platforms compare to one another, especially in important variables such as energy delivery to the eye. To date, it has been unknown how the amount of energy delivered by these phaco platforms differs, if at all, when using identical settings during surgery. We did this study to find out if there are energy differences. To do this research, our lab used calorimetry, which is a way of measuring energy transfer, to compare three different surgical platforms at the same settings. We found a statistically significant difference in amount of energy between these surgical platforms. These results are important because they may help surgeons to understand that the amount of energy delivered during cataract surgery will be different depending on which surgical platform they are using and help to prevent adverse outcomes caused by delivering too much energy to the eye.
- Open Access
- 1 October 2024
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. ume 17, 339-348
Discrepancies in CDE and Measured Phaco Tip Energy: Comparison of Energy Produced in Longitudinal and Torsional Ultrasound Using Calorimetry
Purpose: This study aims to investigate the differences between the heat energy produced during cataract surgery and Cumulative dissipated energy (CDE). CDE is often used as a medium for understanding the energy delivered to the eye during cataract surgery. However, the actual energy produced at the tip level of the tip is not well understood. We propose that a discrepancy may exist between the CDE reported by the surgical machine and the actual energy delivered to the eye. Methods: About 50 mL of distilled water were degassed and placed in an isobaric calorimeter. Using the Alcon Centurion and Ozil handpiece fitted with the balanced tip, an investigator immersed the phaco tip into the water and pressed the foot pedal to position 3. The device was set to 100% continuous power, vacuum to 0 mmHg, with aspiration 12 mL/min aspiration. To prevent system changes in the system within the calorimeter, the aspiration tubing was occluded. Temperature change recorded by another investigator was observed from 0 to 60 seconds. After 60 seconds the first researcher immediately released the pedal and removed the phaco tip from the water. Trials were performed 10 times using solely torsional or longitudinal settings and averaged. CDE also was recorded and averaged. Results: No significant difference was seen in the temperature change or energy calculated in Joules between ultrasound modalities, with torsional producing a magnitude of 163 J and longitudinal producing 172 J (P = 0.2). However, the CDE generated in the 60 seconds period was significantly different, with a magnitude of 61 for longitudinal compared to 24 for torsional (P < 0.001). Conclusion: Significantly more energy was generated using torsional ultrasound than longitudinal at the tip level of the tip. CDE did not appear to accurately reflect these differences. This suggests that other factors should be considered when evaluating CDE and surgical outcomes. Plain Language Summary: This study looked at possible differences between the energy generated during cataract surgery that is reported by the surgical device and the actual energy measured as thermal heat using different machine settings, namely longitudinal and torsional ultrasound. A common metric used for energy delivery to the eye is cumulative dissipated energy. The problem is that this measure accounts for the energy delivered to the eye where the surgical instrument passes through the cornea. Energy that is produced by the rest of the instrument that is inside the eye is less understood, although others have studied postoperative outcomes. We used a method called calorimetry to measure the thermal heat produced by the entire tip and compared this to what the machine reported as cumulative dissipated energy. Calorimetry calculates energy by measuring the change in temperature of liquids. The surgical instrument generated heat in a chamber containing water, and we used the change in temperature to calculate the energy produced by the surgical instrument. We found that longitudinal and torsional ultrasound produced similar heat energy, but the machine reported very different energy. Our results suggest that the machine may not be reporting all of the energy which the surgical instrument produces, and that surgeons may not be able to rely on cumulative dissipated energy to predict operative outcomes.
- 1 October 2024
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. ume 17, 339-348
Open AccessDiscrepancies in CDE and Measured Phaco Tip Energy: Comparison of Energy Produced in Longitudinal and Torsional Ultrasound Using Calorimetry
Purpose: This study aims to investigate the differences between the heat energy produced during cataract surgery and Cumulative dissipated energy (CDE). CDE is often used as a medium for understanding the energy delivered to the eye during cataract surgery. However, the actual energy produced at the tip level of the tip is not well understood. We propose that a discrepancy may exist between the CDE reported by the surgical machine and the actual energy delivered to the eye. Methods: About 50 mL of distilled water were degassed and placed in an isobaric calorimeter. Using the Alcon Centurion and Ozil handpiece fitted with the balanced tip, an investigator immersed the phaco tip into the water and pressed the foot pedal to position 3. The device was set to 100% continuous power, vacuum to 0 mmHg, with aspiration 12 mL/min aspiration. To prevent system changes in the system within the calorimeter, the aspiration tubing was occluded. Temperature change recorded by another investigator was observed from 0 to 60 seconds. After 60 seconds the first researcher immediately released the pedal and removed the phaco tip from the water. Trials were performed 10 times using solely torsional or longitudinal settings and averaged. CDE also was recorded and averaged. Results: No significant difference was seen in the temperature change or energy calculated in Joules between ultrasound modalities, with torsional producing a magnitude of 163 J and longitudinal producing 172 J (P = 0.2). However, the CDE generated in the 60 seconds period was significantly different, with a magnitude of 61 for longitudinal compared to 24 for torsional (P < 0.001). Conclusion: Significantly more energy was generated using torsional ultrasound than longitudinal at the tip level of the tip. CDE did not appear to accurately reflect these differences. This suggests that other factors should be considered when evaluating CDE and surgical outcomes. Plain Language Summary: This study looked at possible differences between the energy generated during cataract surgery that is reported by the surgical device and the actual energy measured as thermal heat using different machine settings, namely longitudinal and torsional ultrasound. A common metric used for energy delivery to the eye is cumulative dissipated energy. The problem is that this measure accounts for the energy delivered to the eye where the surgical instrument passes through the cornea. Energy that is produced by the rest of the instrument that is inside the eye is less understood, although others have studied postoperative outcomes. We used a method called calorimetry to measure the thermal heat produced by the entire tip and compared this to what the machine reported as cumulative dissipated energy. Calorimetry calculates energy by measuring the change in temperature of liquids. The surgical instrument generated heat in a chamber containing water, and we used the change in temperature to calculate the energy produced by the surgical instrument. We found that longitudinal and torsional ultrasound produced similar heat energy, but the machine reported very different energy. Our results suggest that the machine may not be reporting all of the energy which the surgical instrument produces, and that surgeons may not be able to rely on cumulative dissipated energy to predict operative outcomes.