Ramprasad M. Nambisan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ramprasad M. Nambisan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bimala Pant
Nepal Agricultural Research Council, National Plant Pathology Research Centre, Lalitpur 44700, Bagmati Province, Nepal
1 shared publication Grace H. Elta
Division of Gastroenterology, Department of Internal Medicine, University of Michigan Health System, Ann Arbor, USA
1 shared publicationRichard S. Kwon
Division of Gastroenterology, Department of Internal Medicine, University of Michigan Health System, Ann Arbor, USA
1 shared publication- S. Santosh Kumar
CSIR–Central Electronics Engineering Research Institute (CEERI)
1 shared publication - Scott Ryan Green
Center for Wireless Integrated MicroSensing and Systems, University of Michigan, Ann Arbor, MI, USA
1 shared publication Yogesh B. Gianchandani
EECS Department and Center for Wireless Integrated Microsystems and Sensing, University of Michigan, Ann Arbor, USA
1 shared publication
Latest Publications
- Open Access
- 31 October 2024
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 10 (1) , 1-9
A microsystem for in vivo wireless monitoring of plastic biliary stents using magnetoelastic sensors
With an interest in monitoring the patency of stents that are used to treat strictures in the bile duct, this paper reports the investigation of a wireless sensing system to interrogate a microsensor integrated into the stent. The microsensor is comprised of a 28-μm-thick magnetoelastic foil with 8.25-mm length and 1-mm width. Magnetic biasing is provided by permanent magnets attached to the foil. These elements are incorporated into a customized 3D polymeric package. The system electromagnetically excites the magnetoelastic resonant sensor and measures the resulting signal. Through shifts in resonant frequency and quality factor, the sensor is intended to provide an early indication of sludge accumulation in the stent. This work focuses on challenges associated with sensor miniaturization and placement, wireless range, drive signal feedthrough, and clinical use. A swine specimen in vivo experiment is described. Following endoscopic implantation of the sensor enabled plastic stent into the bile duct, at a range of approximately 17 cm, the signal-to-noise ratio of ~106 was observed with an interrogation time of 336 s. These are the first reported signals from a passive wireless magnetoelastic sensor implanted in a live animal.
- 31 October 2024
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 10 (1) , 1-9
Open AccessA microsystem for in vivo wireless monitoring of plastic biliary stents using magnetoelastic sensors
With an interest in monitoring the patency of stents that are used to treat strictures in the bile duct, this paper reports the investigation of a wireless sensing system to interrogate a microsensor integrated into the stent. The microsensor is comprised of a 28-μm-thick magnetoelastic foil with 8.25-mm length and 1-mm width. Magnetic biasing is provided by permanent magnets attached to the foil. These elements are incorporated into a customized 3D polymeric package. The system electromagnetically excites the magnetoelastic resonant sensor and measures the resulting signal. Through shifts in resonant frequency and quality factor, the sensor is intended to provide an early indication of sludge accumulation in the stent. This work focuses on challenges associated with sensor miniaturization and placement, wireless range, drive signal feedthrough, and clinical use. A swine specimen in vivo experiment is described. Following endoscopic implantation of the sensor enabled plastic stent into the bile duct, at a range of approximately 17 cm, the signal-to-noise ratio of ~106 was observed with an interrogation time of 336 s. These are the first reported signals from a passive wireless magnetoelastic sensor implanted in a live animal.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Sensitivity and non-linearity study and performance enhancement in bossed diaphragm piezoresistive pressure sensor
This paper describes a comparative study of sensitivity and non-linearity of conventional and bossed diaphragm piezoresistive pressure sensor along with a performance enhanced design. The proposed structures take into consideration corner compensation to avoid distortion of the mesa structure during fabrication of bossed diaphragm structure using wet bulk micromachining. Optimum piezoresistors locations are calculated with the help of simulations carried out using finite element method (FEM) based tool COMSOL © Multiphysics. Since the sensitivity and non-linearity of conventional and bossed diaphragm structures showed a linear trend, empirical formulae are proposed using linear fit for quick and approximate calculation of sensitivity and non-linearity for a particular sensor structure. It is observed that high stress regions are also present near the boss - diaphragm interface and hence a design with piezoresistors placed at these regions is also proposed. This design is found to be enhancing the performance of piezoresistive pressure sensor compared to the conventional piezoresistor placement.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Sensitivity and non-linearity study and performance enhancement in bossed diaphragm piezoresistive pressure sensor
This paper describes a comparative study of sensitivity and non-linearity of conventional and bossed diaphragm piezoresistive pressure sensor along with a performance enhanced design. The proposed structures take into consideration corner compensation to avoid distortion of the mesa structure during fabrication of bossed diaphragm structure using wet bulk micromachining. Optimum piezoresistors locations are calculated with the help of simulations carried out using finite element method (FEM) based tool COMSOL © Multiphysics. Since the sensitivity and non-linearity of conventional and bossed diaphragm structures showed a linear trend, empirical formulae are proposed using linear fit for quick and approximate calculation of sensitivity and non-linearity for a particular sensor structure. It is observed that high stress regions are also present near the boss - diaphragm interface and hence a design with piezoresistors placed at these regions is also proposed. This design is found to be enhancing the performance of piezoresistive pressure sensor compared to the conventional piezoresistor placement.