Ying Xiong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ying Xiong has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Gang Liu
Shenyang National Laboratory for Materials Science Institute of Metal Research Chinese Academy of Sciences Shenyang China
2 shared publications - Wenjie Li
Tongji University
2 shared publications - Xianfeng Tang
School of Physical Science and Technology, Southwest Jiaotong University (SWJTU), Chengdu 611756, China
2 shared publications - Yangchao Tian
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
2 shared publications - Yong Guan
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
2 shared publications - Changlin Tian
School of Chemistry and Chemical Engineering; Zhangjiang Institute for Advanced Study; The International Peace Maternity and Child Health Hospital, School of Medicine; Shanghai Jiao Tong University, Shanghai 200240, China
1 shared publication
Latest Publications
- Open Access
- 22 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (11) , 2232
Design of a Rapid License Plate Localization Algorithm Utilizing Color Statistical Features
Aiming at the problems of weak background adaptive ability, high dependence on edge features, high computational complexity of some traditional license plate location algorithms, high deployment cost and strong training dependence of location model based on deep learning, this paper proposes a fast license plate location algorithm based on statistical color features. The algorithm uses the HSV color space as the main processing channel, and quantifies the regional color distribution characteristics by constructing the hue histogram and calculating its standard deviation and other statistics, which significantly improves the discrimination and illumination adaptability of the license plate mask in complex background. Compared with the lightweight deep learning models such as “You Only Look Once Version 12 Nano”, this algorithm does not need GPU acceleration and model loading, eliminates the need for data training, significantly reduces the deployment cost and complexity, and can run efficiently on the general computing platform. The experimental results show that compared with the YOLOv12n model, the average processing time of this algorithm is shortened by 30.81% (when YOLOv12n is evaluated with GPU) or 48.42% (when YOLOv12n is evaluated with CPU) at the cost of sacrificing about 5.8% positioning accuracy. The positioning accuracy still reaches 93.7%, demonstrating high processing efficiency and excellent platform adaptability. The algorithm has the advantages of being lightweight, efficient and interpretable, and is especially suitable for intelligent parking lots, edge devices and other scenes sensitive to real time, cost and energy consumption.
- 22 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (11) , 2232
Open AccessDesign of a Rapid License Plate Localization Algorithm Utilizing Color Statistical Features
Aiming at the problems of weak background adaptive ability, high dependence on edge features, high computational complexity of some traditional license plate location algorithms, high deployment cost and strong training dependence of location model based on deep learning, this paper proposes a fast license plate location algorithm based on statistical color features. The algorithm uses the HSV color space as the main processing channel, and quantifies the regional color distribution characteristics by constructing the hue histogram and calculating its standard deviation and other statistics, which significantly improves the discrimination and illumination adaptability of the license plate mask in complex background. Compared with the lightweight deep learning models such as “You Only Look Once Version 12 Nano”, this algorithm does not need GPU acceleration and model loading, eliminates the need for data training, significantly reduces the deployment cost and complexity, and can run efficiently on the general computing platform. The experimental results show that compared with the YOLOv12n model, the average processing time of this algorithm is shortened by 30.81% (when YOLOv12n is evaluated with GPU) or 48.42% (when YOLOv12n is evaluated with CPU) at the cost of sacrificing about 5.8% positioning accuracy. The positioning accuracy still reaches 93.7%, demonstrating high processing efficiency and excellent platform adaptability. The algorithm has the advantages of being lightweight, efficient and interpretable, and is especially suitable for intelligent parking lots, edge devices and other scenes sensitive to real time, cost and energy consumption.
- Open Access
- 7 November 2024
- Published by MDPI AG in Electronics
- Vol. 13 (22) , 4370
A Tunable Microstrip-to-Waveguide Transition for Emergency Satellite Communication Systems
A tunable microstrip-to-waveguide transition is proposed for the ground station of emergency satellite communication systems. The proposed transition, consisting of a microstrip, three matched patches, three waveguides, and three metal screws, can not only convert the microstrip’s TEM-dominated mode into the waveguide’s TE mode within the transmitting frequency band, but also possesses the ability to filter out the amplified noise signals within the receiving frequency band around 12.5 GHz. Importantly, by adjusting the screws’ lengths, it is feasible to change the suppression frequency within the receiving frequency band and keep a good match within the transmitting frequency band. The measured results demonstrate that the proposed transition has a return loss of over 10 dB from 14 to 14.5 GHz and an out-of-band suppression of over 20 dB, from 12.25 to 12.7 GHz, with a typical value of −48 dB around 12.55 GHz. This unique feature eliminates the need for additional waveguide filters that prevent the amplified noise signal, thereby contributing to the miniaturization of the ground station.
- 7 November 2024
- Published by MDPI AG in Electronics
- Vol. 13 (22) , 4370
Open AccessA Tunable Microstrip-to-Waveguide Transition for Emergency Satellite Communication Systems
A tunable microstrip-to-waveguide transition is proposed for the ground station of emergency satellite communication systems. The proposed transition, consisting of a microstrip, three matched patches, three waveguides, and three metal screws, can not only convert the microstrip’s TEM-dominated mode into the waveguide’s TE mode within the transmitting frequency band, but also possesses the ability to filter out the amplified noise signals within the receiving frequency band around 12.5 GHz. Importantly, by adjusting the screws’ lengths, it is feasible to change the suppression frequency within the receiving frequency band and keep a good match within the transmitting frequency band. The measured results demonstrate that the proposed transition has a return loss of over 10 dB from 14 to 14.5 GHz and an out-of-band suppression of over 20 dB, from 12.25 to 12.7 GHz, with a typical value of −48 dB around 12.55 GHz. This unique feature eliminates the need for additional waveguide filters that prevent the amplified noise signal, thereby contributing to the miniaturization of the ground station.
- 7 November 2011
- Published by Wiley in Microscopy Research and Technique
- Vol. 75 (5) , 662-666
Quantitative 3D imaging of yeast by hard X‐ray tomography
Full‐field hard X‐ray tomography could be used to obtain three‐dimensional (3D) nanoscale structures of biological samples. The image of the fission yeast, Schizosaccharomyces pombe, was clearly visualized based on Zernike phase contrast imaging technique and heavy metal staining method at a spatial resolution better than 50 nm at the energy of 8 keV. The distributions and shapes of the organelles during the cell cycle were clearly visualized and two types of organelle were distinguished. The results for cells during various phases were compared and the ratios of organelle volume to cell volume can be analyzed quantitatively. It showed that the ratios remained constant between growth and division phase and increased strongly in stationary phase, following the shape and size of two types of organelles changes. Our results demonstrated that hard X‐ray microscopy was a complementary method for imaging and revealing structural information for biological samples. Microsc. Res. Tech., 2012.
- 7 November 2011
- Published by Wiley in Microscopy Research and Technique
- Vol. 75 (5) , 662-666
Quantitative 3D imaging of yeast by hard X‐ray tomography
Full‐field hard X‐ray tomography could be used to obtain three‐dimensional (3D) nanoscale structures of biological samples. The image of the fission yeast, Schizosaccharomyces pombe, was clearly visualized based on Zernike phase contrast imaging technique and heavy metal staining method at a spatial resolution better than 50 nm at the energy of 8 keV. The distributions and shapes of the organelles during the cell cycle were clearly visualized and two types of organelle were distinguished. The results for cells during various phases were compared and the ratios of organelle volume to cell volume can be analyzed quantitatively. It showed that the ratios remained constant between growth and division phase and increased strongly in stationary phase, following the shape and size of two types of organelles changes. Our results demonstrated that hard X‐ray microscopy was a complementary method for imaging and revealing structural information for biological samples. Microsc. Res. Tech., 2012.
- Open Access
- 1 October 2010
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 17 (6) , 782-785
The study of the reconstructed three-dimensional structure of a solid-oxide fuel-cell cathode by X-ray nanotomography
The microstructure and morphology of solid-oxide fuel-cell electrodes are very complex but important because they strongly affect the electrical performance of the cell. In this work the high-resolution X-ray nanotomography technique is applied to reconstruct the three-dimensional microstructure of a (La(0.8)Sr(0.2))(0.95)MnO(3) yttria-stabilized zirconia composite cathode. Some key microstructural parameters, such as the porosity, representative elementary volume, connected pore volume and pore phase tortuosity, were obtained based on the three-dimensional reconstruction volume data with a spatial resolution of sub-60 nm. These parameters bear intimate correlation with the efficiency of the electrochemical conversion process, and provide valuable information for optimizing the manufacturing processes and improving the device's reliability.
- 1 October 2010
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 17 (6) , 782-785
Open AccessThe study of the reconstructed three-dimensional structure of a solid-oxide fuel-cell cathode by X-ray nanotomography
The microstructure and morphology of solid-oxide fuel-cell electrodes are very complex but important because they strongly affect the electrical performance of the cell. In this work the high-resolution X-ray nanotomography technique is applied to reconstruct the three-dimensional microstructure of a (La(0.8)Sr(0.2))(0.95)MnO(3) yttria-stabilized zirconia composite cathode. Some key microstructural parameters, such as the porosity, representative elementary volume, connected pore volume and pore phase tortuosity, were obtained based on the three-dimensional reconstruction volume data with a spatial resolution of sub-60 nm. These parameters bear intimate correlation with the efficiency of the electrochemical conversion process, and provide valuable information for optimizing the manufacturing processes and improving the device's reliability.