Herviana
Research Subjects
Herviana has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bonhyuk Ku
Department of Electrical Engineering, Korea National University of Transportation, Chungju, South Korea
3 shared publications - Hyoungku Kang
Department of Electrical Engineering, Korea National University of Transportation, Chungju-si, Korea
3 shared publications - Jaesang Kim
Korea National University of Transportation,Dept. of Electrical Engineering,Chungju,Rep. of Korea
3 shared publications - Minkyung Jeong
Department of Electrical Engineering, Korea National University of Transportation, Chungju-si, Korea
3 shared publications - Yechan Kim
Department of Electrical Engineering, Korea National University of Transportation, Chungju, Republic of Korea
3 shared publications
Latest Publications
- 20 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 774-776
Lifespan Evaluation of GIS Under Tropical Climate Conditions: An Environmental Impact Analysis
This study investigates the effect of tropical climates on the durability and efficiency of GIS (Gas-Insulated Switchgear) in Indonesia, characterized by high humidity, temperature fluctuations, and heavy rainfall. By analyzing operational and failure data of local GIS units and comparing them with CIGRE Technical Brochure benchmarks, this study highlights how environmental conditions accelerate GIS degradation in tropical climates. The research extends beyond lifespan statistics to explore how specific tropical conditions-such as corrosion, insulation damage, and condensation-affect GIS failure modes. The study identifies environmental factors and their degradation mechanisms, suggesting targeted maintenance strategies to mitigate the effects of tropical climates on GIS. The findings offer practical guidelines for utilities in similar environments, emphasizing climate-adapted maintenance to enhance the longevity and reliability of power infrastructure. This evaluation provides valuable insights into electrical engineering, highlighting the importance of considering climate in asset management and maintenance for sustainable power infrastructure in weather-sensitive regions.
- 20 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 774-776
Lifespan Evaluation of GIS Under Tropical Climate Conditions: An Environmental Impact Analysis
This study investigates the effect of tropical climates on the durability and efficiency of GIS (Gas-Insulated Switchgear) in Indonesia, characterized by high humidity, temperature fluctuations, and heavy rainfall. By analyzing operational and failure data of local GIS units and comparing them with CIGRE Technical Brochure benchmarks, this study highlights how environmental conditions accelerate GIS degradation in tropical climates. The research extends beyond lifespan statistics to explore how specific tropical conditions-such as corrosion, insulation damage, and condensation-affect GIS failure modes. The study identifies environmental factors and their degradation mechanisms, suggesting targeted maintenance strategies to mitigate the effects of tropical climates on GIS. The findings offer practical guidelines for utilities in similar environments, emphasizing climate-adapted maintenance to enhance the longevity and reliability of power infrastructure. This evaluation provides valuable insights into electrical engineering, highlighting the importance of considering climate in asset management and maintenance for sustainable power infrastructure in weather-sensitive regions.
- 20 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 576-579
Condition Assessment for Extending the Life of Aged 25.8kV GIS Using Worst Code Approach
The objective of this study was to establish a foundation for investigating the possibility of extending the lifespan of a 27-year-old 25.8kV GIS (Gas-Insulated Switchgear) that was operated indoors. Recognizing that traditional time-based replacement strategies may not reflect the true condition of such critical infrastructure, our research adopted a detailed examination protocol. In order to guarantee a comprehensive examination of the components and a reflection of the test results, we have departed from the conventional methodology of utilizing weighted sums for the assessment of health. Instead, we have adopted a ‘Worst Code’ approach. This approach focuses on the condition of the most degraded component to provide a more precise evaluation of the GIS's overall health, enhancing the accuracy of maintenance decisions. Our findings suggest that condition-based assessments, through a structured and quantitative evaluation using the ‘Worst Code’ method, could extend the operational lifetime of GIS units, challenging the conventional time-based criteria in South Korea. This methodology offers a strategic, efficient, and cost-effective asset management practice, indicating a shift towards more accurate evaluations based on actual condition rather than fixed time limits, with implications for aging electrical infrastructure maintenance strategies.
- 20 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 576-579
Condition Assessment for Extending the Life of Aged 25.8kV GIS Using Worst Code Approach
The objective of this study was to establish a foundation for investigating the possibility of extending the lifespan of a 27-year-old 25.8kV GIS (Gas-Insulated Switchgear) that was operated indoors. Recognizing that traditional time-based replacement strategies may not reflect the true condition of such critical infrastructure, our research adopted a detailed examination protocol. In order to guarantee a comprehensive examination of the components and a reflection of the test results, we have departed from the conventional methodology of utilizing weighted sums for the assessment of health. Instead, we have adopted a ‘Worst Code’ approach. This approach focuses on the condition of the most degraded component to provide a more precise evaluation of the GIS's overall health, enhancing the accuracy of maintenance decisions. Our findings suggest that condition-based assessments, through a structured and quantitative evaluation using the ‘Worst Code’ method, could extend the operational lifetime of GIS units, challenging the conventional time-based criteria in South Korea. This methodology offers a strategic, efficient, and cost-effective asset management practice, indicating a shift towards more accurate evaluations based on actual condition rather than fixed time limits, with implications for aging electrical infrastructure maintenance strategies.
- 20 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 770-773
Condition Assessment for Extending the Life of Aged 7.2kV Switchgear Using Worst Code Approach
This study advances the assessment of aged electrical infrastructure to enhance the longevity and reliability of electrical distribution systems. We conducted a detailed condition evaluation of approximately 30-year-old 7.2kV switchgear using the ‘Worst Code’ evaluation method, which focuses on the condition of the most degraded component rather than aggregating scores across components. This approach yields a more accurate reflection of the switchgear's operational condition, avoiding the issues of traditional aggregated assessments that might conceal critical weaknesses. Our findings suggest that, contrary to time-based replacement strategies, targeted reconditioning can significantly extend the operational lifetime of switchgear beyond its expected lifespan. By employing a structured evaluation and the Worst Code method, this research promotes more accurate condition assessments, supporting better-informed decisions on maintenance and life extension of switchgear units. Furthermore, it underscores the value of condition-based assessments and customized reconditioning in improving asset management, thereby enhancing utilization, reducing unnecessary replacements, and optimizing maintenance budgets. This research advocates for the use of advanced condition assessment methods to ensure the sustainable management, maintenance, and life extension of electrical switchgear.
- 20 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 770-773
Condition Assessment for Extending the Life of Aged 7.2kV Switchgear Using Worst Code Approach
This study advances the assessment of aged electrical infrastructure to enhance the longevity and reliability of electrical distribution systems. We conducted a detailed condition evaluation of approximately 30-year-old 7.2kV switchgear using the ‘Worst Code’ evaluation method, which focuses on the condition of the most degraded component rather than aggregating scores across components. This approach yields a more accurate reflection of the switchgear's operational condition, avoiding the issues of traditional aggregated assessments that might conceal critical weaknesses. Our findings suggest that, contrary to time-based replacement strategies, targeted reconditioning can significantly extend the operational lifetime of switchgear beyond its expected lifespan. By employing a structured evaluation and the Worst Code method, this research promotes more accurate condition assessments, supporting better-informed decisions on maintenance and life extension of switchgear units. Furthermore, it underscores the value of condition-based assessments and customized reconditioning in improving asset management, thereby enhancing utilization, reducing unnecessary replacements, and optimizing maintenance budgets. This research advocates for the use of advanced condition assessment methods to ensure the sustainable management, maintenance, and life extension of electrical switchgear.